← Back
Three families
430 EAST 154 STREET
BRONX · BIN 2117406
💬 Discuss this project
2007Year Built
3Stories
C0Building Class
R6Zoning
3,900 sfGross Floor Area
3Units
39 Open Violations 29 unresolved · 10 paperwork only ▸
Three families · 2,500 sf lot · 1.56 FAR built · Flood zone X
Locations of Work
Architecture
Permit Issued — active, not yet Signed-off
Floor 3Under Construction9p · 1 filing · 20 docs
Floor 2Under Construction9p · 1 filing · 20 docs
Floor 1Under Construction9p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TERRAFORM ARCHITECTURE PLLC405/05/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MONICA SANTOS EXP403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ARANDA PLBG & HTG CORPPlumbing306/28/2026
PACIFIC NOAH'S ARK INTERGeneral Contractor204/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BUILDTECH ENGINEERING6369203/09/2026
Building Lifecycle
All (117)Filed (4)Permit Issued (3)Signed Off (1)Violation (52)Inspection (8)Objection (34)Special Inspection (15)
08/07/2026
Signed off — Alteration CO
THIS APPLICATION IS FILED TO CORRECT THE PREVIOUS CERTIFICATE OF OCCUPANCY AND TO CLEAR ECB VIOLATIONS 35468656Y, 35468657X, 35468658H, 35468659J, 35468660R, 35468661Z, 35468662K, 35468663M, 35468664Y.
X01119782-S2
06/30/2026
Special inspection requirement — HVAC-R and service water heating system controls
EMANUEL KAMBANIS
06/30/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
EMANUEL KAMBANIS
06/30/2026
Special inspection requirement — HVAC-R and service water heating equipment
EMANUEL KAMBANIS
06/04/2026
Objection raised — Other
06/04/2026
Objection resolved — Addressed
05/20/2026
Objection resolved — Addressed
05/19/2026
Objection raised — Other
05/08/2026
Violation issued (HPD, open)
A
05/05/2026
Filed — Alteration CO
THIS APPLICATION IS FILED TO CORRECT THE PREVIOUS CERTIFICATE OF OCCUPANCY AND TO CLEAR ECB VIOLATIONS 35468656Y, 35468657X, 35468658H, 35468659J, 35468660R, 35468661Z, 35468662K, 35468663M, 35468664Y.
X01119782-P2
04/24/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
04/22/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/06/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/06/2026
Special inspection requirement — HVAC-R and service water heating equipment
EMANUEL KAMBANIS
04/06/2026
Special inspection requirement — HVAC-R and service water heating system controls
EMANUEL KAMBANIS
04/06/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
EMANUEL KAMBANIS
04/06/2026
Special inspection requirement — Mechanical Systems
Luis Pichardo
04/06/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Luis Pichardo
04/06/2026
Special inspection requirement — Final
EMANUEL KAMBANIS
03/23/2026
Objection resolved — Addressed
03/20/2026
Objection raised — C/O of existing property requi
03/09/2026
Filed — Alteration CO
THIS APPLICATION IS FILED TO CORRECT THE PREVIOUS CERTIFICATE OF OCCUPANCY AND TO CLEAR ECB VIOLATIONS 35468656Y, 35468657X, 35468658H, 35468659J, 35468660R, 35468661Z, 35468662K, 35468663M, 35468664Y.
X01119782-P1
03/08/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Luis Pichardo
03/08/2026
Special inspection requirement — Mechanical Systems
Luis Pichardo
03/08/2026
Special inspection requirement — Final
EMANUEL KAMBANIS
03/08/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
EMANUEL KAMBANIS
03/08/2026
Special inspection requirement — HVAC-R and service water heating equipment
EMANUEL KAMBANIS
03/08/2026
Special inspection requirement — HVAC-R and service water heating system controls
EMANUEL KAMBANIS
03/04/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
02/18/2026
Permit issued — General Construction
X01119782-I1-GC-CX
02/12/2026
Violation issued (ECB, open)
Construction
02/12/2026
Violation issued (ECB, open)
Construction
02/12/2026
Violation issued (ECB, open)
Construction
02/12/2026
Violation issued (ECB, open)
Construction
02/12/2026
Violation issued (ECB, open)
Construction
02/12/2026
Violation issued (ECB, open)
Construction
01/13/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/12/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
12/19/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
12/16/2025
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
11/17/2025
Violation issued (HPD, open)
I
09/16/2025
Permit issued — Plumbing
X01119782-S2-PL
07/23/2025
Permit issued — General Construction
X01119782-I1-GC-CX
07/17/2025
Filed — Alteration CO
THIS APPLICATION IS FILED TO CORRECT THE PREVIOUS CERTIFICATE OF OCCUPANCY AND TO CLEAR ECB VIOLATIONS 35468656Y, 35468657X, 35468658H, 35468659J, 35468660R, 35468661Z, 35468662K, 35468663M, 35468664Y.
X01119782-S2
06/13/2025
Violation issued (HPD, open)
A
06/11/2025
Objection resolved — Addressed
06/11/2025
Objection resolved — Addressed
06/06/2025
Objection raised — C/O of existing property requi
05/16/2025
Objection raised — C/O of existing property requi
05/06/2025
Objection resolved — Addressed
04/28/2025
Objection raised — C/O of existing property requi
04/28/2025
Objection resolved — Addressed
04/24/2025
Objection raised — Admin
04/18/2025
Objection resolved — Addressed
02/04/2025
Objection raised — C/O of existing property requi
01/30/2025
Objection raised — C/O of existing property requi
01/30/2025
Objection resolved — Addressed
01/23/2025
Objection resolved — Addressed
01/03/2025
Objection raised — C/O of existing property requi
12/27/2024
Objection resolved — Addressed
Latest 60 of 117 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedPACIFIC NOAH'S ARK INTER02/18/2026
DOB NOWPlumbingSigned-offARANDA PLBG & HTG CORP09/16/2025
DOB NOWGeneral ConstructionPermit IssuedPACIFIC NOAH'S ARK INTER07/23/2025
BIS—ISSUEDDBA A TO Z HOME IMPROVEMENT06/29/2007
BISEQISSUEDDBA A TO Z HOME IMPROVEMENT06/29/2007
BIS—ISSUEDDBA A TO Z HOME IMPROVEMENT12/18/2006
BISPLISSUEDWAGNER ZIV PLUMBING & HEATING CO02/02/2006
1 project · most recent 05/05/2026
Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
05/05/2026Permit IssuedPACIFIC NOAH'S ARK INTERHeating Systems
Heating
Weil-Mclain CGA-25-SPDN 52,000 BTU · Boiler ×6
1 project · most recent 05/05/2026
Gas Water/Sanitary
FiledStatusContractorScope
05/05/2026Signed-offARANDA PLBG & HTG CORPGas, Water/Sanitary
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
04/24/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
04/22/2026Pass-Final CND-Occupancy InspectionPassView ↗
04/06/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/04/2026Pass-Final CND-Occupancy InspectionPassView ↗
01/13/2026Pass-Final CND-Occupancy InspectionPassView ↗
01/12/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
12/19/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/16/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
▾Special Inspection Requirements (DOB NOW) — 15
DateRequirementInspectorRole
06/30/2026HVAC-R and service water heating system controlsEMANUEL KAMBANISenergy_progress
06/30/2026HVAC-R and service water piping design and insulationEMANUEL KAMBANISenergy_progress
06/30/2026HVAC-R and service water heating equipmentEMANUEL KAMBANISenergy_progress
04/06/2026HVAC-R and service water heating equipmentEMANUEL KAMBANISenergy_progress
04/06/2026HVAC-R and service water heating system controlsEMANUEL KAMBANISenergy_progress
04/06/2026HVAC-R and service water piping design and insulationEMANUEL KAMBANISenergy_progress
04/06/2026Mechanical SystemsLuis Pichardospecial
04/06/2026Fire-Resistant Penetrations and JointsLuis Pichardospecial
04/06/2026FinalEMANUEL KAMBANISprogress
03/08/2026Fire-Resistant Penetrations and JointsLuis Pichardospecial
03/08/2026Mechanical SystemsLuis Pichardospecial
03/08/2026FinalEMANUEL KAMBANISprogress
03/08/2026HVAC-R and service water piping design and insulationEMANUEL KAMBANISenergy_progress
03/08/2026HVAC-R and service water heating equipmentEMANUEL KAMBANISenergy_progress
03/08/2026HVAC-R and service water heating system controlsEMANUEL KAMBANISenergy_progress
▾Documents — 32 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/16/2026X01119782-S2Request digital key ↗
08/15/2026X01119782-I1Request digital key ↗
08/15/2026X01119782-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWHouse Number Verification: TOPO Stamp2
08/13/2026X01119782-I1Open ↗
08/13/2026X01119782-P1Open ↗
▸Seals & Professional Certifications19
▸DOB NOWProgress Inspector Seal & Signature11
08/31/2026X01119782-I1Open ↗
08/31/2026X01119782-I1Open ↗
08/31/2026X01119782-I1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/16/2026X01119782-I1Open ↗
08/16/2026X01119782-P2Open ↗
08/16/2026X01119782-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/31/2026X01119782-I1Open ↗
08/31/2026X01119782-I1Open ↗
08/28/2026X01119782-P1Open ↗
Showing 3 of 4 on file for this type
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist2
08/15/2026X01119782-I1Open ↗
08/15/2026X01119782-P1Open ↗
▸Approvals, Objections & Sign-offs2
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
12/28/2017200981330Open ↗
07/06/2017200981330Open ↗
▸Other Documents3
▸DOB NOWProperty Ownership Certification2
08/15/2026X01119782-I1Open ↗
08/15/2026X01119782-P1Open ↗
▸DOB NOWFinal Survey1
08/15/2026X01119782-I1Open ↗