← Back
BRONX
810 EAST 169 STREET
BRONX · BIN 2131080
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
Locations of Work
Architecture
Cellar1p · 1 filing · 15 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MANAGEMENT109/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SION CONSULTING ENGINEERING PC308/06/2026
Building Lifecycle
All (42)Filed (3)Objection (9)Special Inspection (30)
08/12/2026
Objection raised — C/O of existing property requi
08/12/2026
Objection raised — Energy
08/06/2026
Filed — New Building
THIS APPLICATION IS FILED FOR THE INSTALLATION OF 8' HIGH TEMPORARY CONSTRUCTION FENCE AROUND JOB SITE IN CONJUNCTION WITH NEW BUILDING APPLICATION # X01207375-S2
X01207375-S1
08/06/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
08/06/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
08/06/2026
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
08/06/2026
Special inspection requirement — Energy Code Compliance Inspections
08/06/2026
Special inspection requirement — HVAC-R and service water heating system controls
08/06/2026
Special inspection requirement — HVAC-R and service water heating equipment
08/06/2026
Special inspection requirement — Permanent certificate
08/06/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
05/27/2026
Objection resolved — Resolved
05/27/2026
Objection resolved — Resolved
04/29/2026
Objection raised — Energy
04/29/2026
Objection raised — Other
04/29/2026
Objection raised — Other
04/27/2026
Objection resolved — Resolved
04/26/2026
Objection raised — Admin
04/20/2026
Filed — New Building
THIS APPLICATION IS FILED FOR THE INSTALLATION OF 8' HIGH TEMPORARY CONSTRUCTION FENCE AROUND JOB SITE IN CONJUNCTION WITH NEW BUILDING APPLICATION # X01207375-S2
X01207375-I1
04/20/2026
Filed — New Building
THIS APPLICATION IS FILED FOR THE INSTALLATION OF 8' HIGH TEMPORARY CONSTRUCTION FENCE AROUND JOB SITE IN CONJUNCTION WITH NEW BUILDING APPLICATION # X01207375-S2
X01207375-S2
04/20/2026
Special inspection requirement — Metering
04/20/2026
Special inspection requirement — Maintenance information
04/20/2026
Special inspection requirement — Interior lighting power
04/07/2026
Special inspection requirement — Heating Systems
04/07/2026
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
03/24/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/24/2026
Special inspection requirement — Masonry
03/24/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
03/24/2026
Special inspection requirement — Subgrade Inspections
03/24/2026
Special inspection requirement — Energy Code Compliance Inspections
03/24/2026
Special inspection requirement — Fire-Resistance Rated Construction
03/24/2026
Special inspection requirement — Concrete - Cast-In-Place
03/24/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
03/24/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
06/23/2025
Special inspection requirement — Air barrier — testing
06/23/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
06/23/2025
Special inspection requirement — Air barrier - visual inspection
06/23/2025
Special inspection requirement — Fenestration areas
06/23/2025
Special inspection requirement — Insulation placement and R values
06/23/2025
Special inspection requirement — Ventilation and air distribution system
06/23/2025
Special inspection requirement — HVAC-R and service water heating equipment
06/23/2025
Special inspection requirement — Structural Cold-Formed Steel
Nothing on file for this building.
1 project · most recent 08/06/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/06/2026——Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MITSUBISHI - MXZ-5C42NA4 42,000 BTU · Vrf Outdoor ×3
Ventilation
— PANASONIC FV-11VQ5 , FV-15VQ5 150 CFM · Exhaust Fan ×6
1 project · most recent 08/06/2026
Storm Water/Sanitary
FiledStatusContractorScope
08/06/2026——Storm, Water/Sanitary
1 project · most recent 08/06/2026
Concrete Masonry
FiledStatusContractorScope
08/06/2026——Concrete, Masonry
1 project · most recent 08/06/2026
Fence
FiledStatusContractorScope
08/06/2026——Fence
▾Special Inspection Requirements (DOB NOW) — 37
DateRequirementInspectorRole
08/06/2026Fire-Resistant Penetrations and Joints—special
08/06/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation—special
08/06/2026Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities—special
08/06/2026Energy Code Compliance Inspections—progress
08/06/2026HVAC-R and service water heating system controls—energy_progress
08/06/2026HVAC-R and service water heating equipment—energy_progress
08/06/2026Permanent certificate—energy_progress
08/06/2026HVAC-R and service water piping design and insulation—energy_progress
04/20/2026Metering—energy_progress
04/20/2026Maintenance information—energy_progress
04/20/2026Interior lighting power—energy_progress
04/07/2026Heating Systems—special
04/07/2026Exterior Insulation and Finish Systems (EIFS)—special
03/24/2026Fire-Resistant Penetrations and Joints—special
03/24/2026Masonry—special
03/24/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation—special
03/24/2026Subgrade Inspections—special
03/24/2026Energy Code Compliance Inspections—progress
03/24/2026Fire-Resistance Rated Construction—progress
03/24/2026Concrete - Cast-In-Place—special
03/24/2026Excavations - Sheeting, Shoring, and Bracing—special
03/24/2026Subsurface Investigations (Borings/Test Pits)—special
06/23/2025Air barrier — testing —energy_progress
06/23/2025HVAC-R and service water piping design and insulation—energy_progress
06/23/2025Air barrier - visual inspection—energy_progress
Latest 25 of 37.
▾Documents — 15 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/26/2026X01207375-I1Request digital key ↗
08/17/2026X01207375-I1Request digital key ↗
08/17/2026X01207375-S1Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram1
08/17/2026X01207375-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/17/2026X01207375-I1Open ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/17/2026X01207375-S1Open ↗
08/17/2026X01207375-I1Open ↗
08/17/2026X01207375-S2Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/17/2026X01207375-I1Open ↗
▸Inspections & Test Reports2
▸DOB NOWTR4 Test Report and Plot Diagram1
08/17/2026X01207375-I1Open ↗
▸DOB NOWSOIL REPORT1
08/17/2026X01207375-I1Open ↗
▸Other Documents3
▸DOB NOWProperty Ownership Certification1
08/17/2026X01207375-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/17/2026X01207375-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1