Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionCivil
Permit Issued — active, not yet Signed-off
Floor 2Under Construction11p · 1 filing · 20 docs
Floor 1Under Construction10p · 1 filing · 20 docs
CellarUnder Construction12p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SION CONSULTING ENGINEERING PC708/10/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SION CONSULTING ENGINEERING403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
H BUILDING MANAGEMENT INCGeneral Contractor807/08/2026
HORBRIDGE PLUMBING & HEATINGPlumbing208/31/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SION CONSULTING ENG. PC1108408/10/2026
Building Lifecycle
All (68)Filed (6)Permit Issued (8)Inspection (2)Objection (22)Special Inspection (30)
08/21/2026
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
08/10/2026
Filed — New Building
THIS APPLICATION IS FILED TO ADD NEW PLUMBING FIXTURES.
X01210563-P1
07/17/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/07/2026
Permit issued — Plumbing
X01210563-S4-PL
07/07/2026
Permit issued — Plumbing
X01210563-S1-PL
04/24/2026
Objection raised — Fire_Protection
04/24/2026
Objection raised — Fire_Protection
03/25/2026
Objection resolved — Resolved
03/11/2026
Objection raised — Admin
02/19/2026
Filed — New Building
THIS APPLICATION IS FILED TO ADD NEW PLUMBING FIXTURES.
X01210563-S4
02/18/2026
Special inspection requirement — Sprinkler Systems
sion hourizadeh
02/16/2026
Special inspection requirement — Sprinkler Systems
11/18/2025
Objection resolved — Addressed
11/17/2025
Objection raised — Admin
11/07/2025
Objection resolved — Addressed
11/06/2025
Objection resolved — Addressed
11/06/2025
Objection resolved — Addressed
11/06/2025
Objection resolved — Addressed
11/06/2025
Objection resolved — Addressed
10/23/2025
Permit issued — General Construction
X01210563-I1-ST
10/23/2025
Permit issued — Earth Work
X01210563-I1-FO
10/23/2025
Permit issued — Structural
X01210563-I1-EA
10/21/2025
Permit issued — Mechanical Systems
X01210563-I1-MS
10/14/2025
Permit issued — General Construction
X01210563-I1-GC
09/30/2025
Permit issued — Construction Fence
X01223057-I1-FN
09/15/2025
Objection resolved — Addressed
09/03/2025
Objection resolved — Addressed
07/10/2025
Objection resolved — Addressed
07/08/2025
Special inspection requirement — Interior lighting power
sion hourizadeh
06/05/2025
Objection raised — Fire_Protection
06/05/2025
Objection raised — Zoning
06/05/2025
Objection raised — Structural
06/05/2025
Objection raised — Structural
06/05/2025
Objection raised — Structural
06/05/2025
Objection raised — Zoning
06/04/2025
Objection raised — Admin
06/04/2025
Objection raised — Energy
05/20/2025
Filed — New Building
THIS APPLICATION IS FILED TO ADD NEW PLUMBING FIXTURES.
X01210563-S2
05/16/2025
Filed — New Building
THIS APPLICATION IS FILED TO ADD NEW PLUMBING FIXTURES.
X01210563-S1
05/15/2025
Filed — Alteration
X01223057-I1
04/24/2025
Filed — New Building
THIS APPLICATION IS FILED TO ADD NEW PLUMBING FIXTURES.
X01210563-I1
04/23/2025
Special inspection requirement — Structural Steel - Details
sion hourizadeh
04/14/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
sion hourizadeh
04/14/2025
Special inspection requirement — Heating Systems
sion hourizadeh
04/14/2025
Special inspection requirement — Masonry
sion hourizadeh
04/14/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
sion hourizadeh
04/14/2025
Special inspection requirement — Subgrade Inspections
sion hourizadeh
04/14/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Rajasekhar Sakhamuri
04/14/2025
Special inspection requirement — Final
sion hourizadeh
04/14/2025
Special inspection requirement — Footing and Foundation
sion hourizadeh
04/14/2025
Special inspection requirement — Energy Code Compliance Inspections
sion hourizadeh
04/14/2025
Special inspection requirement — Fire-Resistance Rated Construction
sion hourizadeh
04/14/2025
Special inspection requirement — Preliminary
sion hourizadeh
04/14/2025
Special inspection requirement — Structural Wood Frame
sion hourizadeh
04/14/2025
Special inspection requirement — Protection of exposed foundation insulation
sion hourizadeh
04/14/2025
Special inspection requirement — Ventilation and air distribution system
sion hourizadeh
04/14/2025
Special inspection requirement — Fenestration areas
sion hourizadeh
04/14/2025
Special inspection requirement — Air barrier — testing
AKM RAHMAN
04/14/2025
Special inspection requirement — Insulation placement and R values
sion hourizadeh
04/14/2025
Special inspection requirement — HVAC-R and service water heating equipment
sion hourizadeh
Latest 60 of 68 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedHORBRIDGE PLUMBING & HEATING07/07/2026
DOB NOWPlumbingPermit IssuedHORBRIDGE PLUMBING & HEATING07/07/2026
DOB NOWGeneral ConstructionPermit IssuedH BUILDING MANAGEMENT INC10/23/2025
DOB NOWEarth WorkPermit IssuedH BUILDING MANAGEMENT INC10/23/2025
DOB NOWStructuralPermit IssuedH BUILDING MANAGEMENT INC10/23/2025
DOB NOWMechanical SystemsPermit IssuedH BUILDING MANAGEMENT INC10/21/2025
DOB NOWGeneral ConstructionPermit IssuedH BUILDING MANAGEMENT INC10/14/2025
DOB NOWConstruction FencePermit IssuedH BUILDING MANAGEMENT INC09/30/2025
1 project · most recent 08/10/2026
Storm Water/Sanitary
FiledStatusContractorScope
08/10/2026Permit IssuedHORBRIDGE PLUMBING & HEATStorm, Water/Sanitary
1 project · most recent 11/24/2025
General Wiring
FiledStatusContractorScope
11/24/2025Permit IssuedPOWER SURGE ELECTRIC, INCGeneral Wiring
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
08/21/2026Pass-Final PL - UndergroundPassView ↗
07/17/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 34
DateRequirementInspectorRole
02/18/2026Sprinkler Systemssion hourizadehspecial
02/16/2026Sprinkler Systems—special
07/08/2025Interior lighting powersion hourizadehenergy_progress
04/23/2025Structural Steel - Detailssion hourizadehspecial
04/14/2025Fire-Resistant Penetrations and Jointssion hourizadehspecial
04/14/2025Heating Systemssion hourizadehspecial
04/14/2025Masonrysion hourizadehspecial
04/14/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installationsion hourizadehspecial
04/14/2025Subgrade Inspectionssion hourizadehspecial
04/14/2025Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
04/14/2025Finalsion hourizadehprogress
04/14/2025Footing and Foundationsion hourizadehprogress
04/14/2025Energy Code Compliance Inspectionssion hourizadehprogress
04/14/2025Fire-Resistance Rated Constructionsion hourizadehprogress
04/14/2025Preliminarysion hourizadehprogress
04/14/2025Structural Wood Framesion hourizadehprogress
04/14/2025Protection of exposed foundation insulationsion hourizadehenergy_progress
04/14/2025Ventilation and air distribution systemsion hourizadehenergy_progress
04/14/2025Fenestration areassion hourizadehenergy_progress
04/14/2025Air barrier — testing AKM RAHMANenergy_progress
04/14/2025Insulation placement and R valuession hourizadehenergy_progress
04/14/2025HVAC-R and service water heating equipmentsion hourizadehenergy_progress
04/14/2025Air barrier - visual inspectionsion hourizadehenergy_progress
04/14/2025Electric vehicle service equipment requirementssion hourizadehenergy_progress
04/14/2025HVAC-R and service water heating system controlssion hourizadehenergy_progress
Latest 25 of 34.
▾Documents — 50 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/19/2026X01223057-I1Request digital key ↗
08/17/2026X01210563-S4Request digital key ↗
08/17/2026X01210563-S3Request digital key ↗
Showing 3 of 7 on file for this type
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram1
08/17/2026X01210563-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/17/2026X01210563-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/17/2026X01210563-I1Open ↗
▸Seals & Professional Certifications31
▸DOB NOWProgress Inspector Seal & Signature22
09/02/2026X01210563-I1Open ↗
09/02/2026X01210563-I1Open ↗
09/02/2026X01210563-I1Open ↗
Showing 3 of 22 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/19/2026X01223057-I1Open ↗
08/17/2026X01210563-S4Open ↗
08/17/2026X01210563-S2Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/19/2026X01210563-S4Open ↗
09/02/2026X01210563-I1Open ↗
09/02/2026X01210563-I1Open ↗
▸Trade Schedules & Equipment1
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/17/2026X01210563-I1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/17/2026X01210563-I1Open ↗
▸DOB NOWStreet Tree Checklist1
08/17/2026X01210563-I1Open ↗
▸Inspections & Test Reports2
▸DOB NOWTR4 Test Report and Plot Diagram1
08/17/2026X01210563-I1Open ↗
▸DOB NOWSOIL REPORT1
08/17/2026X01210563-I1Open ↗
▸Other Documents4
▸DOB NOWProperty Ownership Certification1
08/17/2026X01210563-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/17/2026X01210563-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/17/2026X01210563-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/17/2026X01210563-I1Open ↗