← Back
Two family converted from one family
22 SCHERMERHORN STREET
BROOKLYN · BIN 3002684
💬 Discuss this project
1847Year Built
3Stories
B3Building Class
R6Zoning
4,000 sfGross Floor Area
2Units
Two family converted from one family · Owner of record: SCHERMERHORN TOWNHOUSE 22, LLC · 2,075 sf lot · 1.93 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction2p · 1 filing · 4 docs
Floor 3Under Construction36p · 3 filings · 20 docs
Floor 2Under Construction32p · 3 filings · 20 docs
Floor 1Under Construction32p · 3 filings · 20 docs
CellarUnder Construction35p · 3 filings · 20 docs
BasementUnder Construction2p · 2 filings · 11 docs
Sub-BasementUnder Construction28p · 1 filing · 20 docs
1 job · most recent 11/13/2025
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
11/13/2025Permit IssuedA.L.D. MANAGEMENT SERV INHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric PEFY-P06NMSU-ER2 6,800 BTU · Vrf Indoor ×2
PEFY-P08NMAU-E4 9,000 BTU · Vrf Indoor ×2
PEFY-P06NMAU-E4 6,700 BTU · Vrf Indoor ×1
PEFY-P08NAMU-E1 9,000 BTU · Vrf Indoor ×1
PEFY-P08NMAU-E1 9,000 BTU · Vrf Indoor ×1
PEFY-P08NMSU-ER2 8,900 BTU · Vrf Indoor ×1
PEFY-P12NMAU-E4 13,500 BTU · Vrf Indoor ×1
PVFY-P12NAMU-E1 13,500 BTU · Vrf Indoor ×1
Lg ARUM096BTE5 108,000 BTU · Vrf Outdoor ×1
1 job · most recent 11/13/2025
Gas Water/Sanitary
FiledStatusContractorScope
11/13/2025Permit IssuedGENESIS PLBG AND HTG CORPGas, Water/Sanitary
2 jobs · most recent 03/28/2026
General Wiring
FiledStatusContractorScope
03/28/2026Permit IssuedM & J ELEC'L CONTR'S CORP1 meters, 1 new_meters
12/19/2025Permit IssuedM & J ELEC'L CONTR'S CORPGeneral Wiring
1 job · most recent 11/13/2025
Steel Concrete
FiledStatusContractorScope
11/13/2025Permit IssuedA.L.D. MANAGEMENT SERV INSteel, Concrete
Building Lifecycle
All (48)Filed (6)Permit Issued (11)Inspection (6)Objection (16)Special Inspection (9)
09/14/2026
Permit issued — General Construction
B01245059-S2-ST
06/04/2026
Objection resolved — Resolved
06/02/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
05/29/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/22/2026
Objection raised — Cost
05/21/2026
Objection resolved — Addressed
05/20/2026
Permit issued — Mechanical Systems
B01245059-S4-MS
05/20/2026
Permit issued — General Construction
B01245084-I1-GC
05/20/2026
Permit issued — General Construction
B01245059-I1-GC
05/20/2026
Permit issued — Foundation
B01245059-S2-ST
05/20/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
05/18/2026
Objection raised — Fire_Protection
05/07/2026
Objection resolved — Addressed
05/07/2026
Objection resolved — Addressed
05/07/2026
Objection resolved — Addressed
05/07/2026
Objection resolved — Addressed
05/07/2026
Objection resolved — Addressed
05/07/2026
Objection resolved — Addressed
04/21/2026
Objection raised — Zoning
04/21/2026
Objection raised — Zoning
04/21/2026
Objection raised — Fire_Protection
04/21/2026
Objection raised — Other
04/21/2026
Objection raised — Zoning
04/21/2026
Objection raised — Zoning
04/15/2026
Permit issued — General Construction
B01245084-I1-GC
03/25/2026
Filed — Alteration CO
Application filed to convert two family dwelling to a single-family dwelling
B01364611-I1
03/09/2026
Filed — Alteration
Extrior renovation work as shown on plans filed here with
B01245084-I1
02/06/2026
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
01/05/2026
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
12/05/2025
Permit issued — Mechanical Systems
B01245059-S4-MS
12/04/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/20/2025
Permit issued — Plumbing
B01245059-S3-PL
11/13/2025
Filed — Alteration
Plumbing renovation work as shown on plans filed here with.
B01245059-S3
11/13/2025
Filed — Alteration
Plumbing renovation work as shown on plans filed here with.
B01245059-S4
10/16/2025
Special inspection requirement — Mechanical Systems
ZAKI ALBANNA
10/16/2025
Special inspection requirement — Final
ZAKI ALBANNA
09/18/2025
Permit issued — General Construction
B01245059-S2-ST
09/18/2025
Permit issued — Structural
B01245059-S2-GC-CX
09/15/2025
Filed — Alteration
Plumbing renovation work as shown on plans filed here with.
B01245059-S2
07/16/2025
Permit issued — General Construction
B01245059-I1-GC
07/03/2025
Filed — Alteration
Plumbing renovation work as shown on plans filed here with.
B01245059-I1
07/02/2025
Special inspection requirement — Footing and Foundation
ZAKI ALBANNA
07/02/2025
Special inspection requirement — Structural Steel - Details
ZAKI ALBANNA
07/02/2025
Special inspection requirement — Final
ZAKI ALBANNA
07/02/2025
Special inspection requirement — Structural Cold-Formed Steel
ZAKI ALBANNA
07/02/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
ZAKI ALBANNA
06/23/2025
Special inspection requirement — Final
Eugene Colberg
06/23/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Eugene Colberg
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
GSD2409/15/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/12/2024$5.3M—22 SCHERMERHORN STREET LLC → SCHERMERHORN TOWNHOUSE 22, LLC$1,325/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
COLBERG ARCHITECTURE303/25/2026
COLLECTIF ENGINEERING PLLC211/13/2025
ALBANNA ENGINEERING PC109/15/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
DVA Advisors403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
A.L.D. MANAGEMENT SERV INGeneral Contractor1209/15/2026
GENESIS PLBG AND HTG CORPPlumbing107/02/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
COLBERG ARCHITECTURE7683203/09/2026
ALBANNA ENGINEERING PC2401211/13/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedA.L.D. MANAGEMENT SERV IN09/14/2026
DOB NOWMechanical SystemsPermit IssuedA.L.D. MANAGEMENT SERV IN05/20/2026
DOB NOWGeneral ConstructionPermit IssuedA.L.D. MANAGEMENT SERV IN05/20/2026
DOB NOWGeneral ConstructionPermit IssuedA.L.D. MANAGEMENT SERV IN05/20/2026
DOB NOWFoundationPermit IssuedA.L.D. MANAGEMENT SERV IN05/20/2026
DOB NOWGeneral ConstructionPermit IssuedA.L.D. MANAGEMENT SERV IN04/15/2026
DOB NOWMechanical SystemsPermit IssuedA.L.D. MANAGEMENT SERV IN12/05/2025
DOB NOWPlumbingPermit IssuedGENESIS PLBG AND HTG CORP11/20/2025
DOB NOWGeneral ConstructionPermit IssuedA.L.D. MANAGEMENT SERV IN09/18/2025
DOB NOWStructuralPermit IssuedA.L.D. MANAGEMENT SERV IN09/18/2025
DOB NOWGeneral ConstructionPermit IssuedA.L.D. MANAGEMENT SERV IN07/16/2025
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
06/02/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
05/29/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/20/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
02/06/2026Pass-Final PL - UndergroundPassView ↗
01/05/2026Fail-Final General Construction Non-Directive 14FailView ↗
12/04/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
10/16/2025Mechanical SystemsZAKI ALBANNAspecial
10/16/2025FinalZAKI ALBANNAprogress
07/02/2025Footing and FoundationZAKI ALBANNAprogress
07/02/2025Structural Steel - DetailsZAKI ALBANNAspecial
07/02/2025FinalZAKI ALBANNAprogress
07/02/2025Structural Cold-Formed SteelZAKI ALBANNAspecial
07/02/2025Structural Stability – Alterations of existing buildingsZAKI ALBANNAspecial
06/23/2025FinalEugene Colbergprogress
06/23/2025Fire-Resistant Penetrations and JointsEugene Colbergspecial
▾Documents — 34 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/19/2026B01245059-S2Request digital key ↗
08/19/2026B01245059-S3Request digital key ↗
08/19/2026B01245059-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits5
▸DOB NOWLPC Approval/Permit5
08/15/2026B01364611-I1Open ↗
08/13/2026B01245059-S3Open ↗
08/13/2026B01245059-I1Open ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications12
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/19/2026B01245059-S2Open ↗
08/19/2026B01245059-I1Open ↗
08/19/2026B01245059-S4Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/23/2026B01245059-S4Open ↗
08/28/2026B01245059-S2Open ↗
08/25/2026B01245059-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature3
09/23/2026B01245059-S4Open ↗
08/28/2026B01245059-S2Open ↗
08/25/2026B01245059-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/15/2026B01364611-I1Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/19/2026B01245059-I1Open ↗
08/19/2026B01245059-S2Open ↗
08/19/2026B01245059-S4Open ↗
Showing 3 of 6 on file for this type
▸Approvals, Objections & Sign-offs1
▸DOB NOWLandmark Approval1
08/13/2026B01245084-I1Open ↗
▸Other Documents4
▸DOB NOWProof of Historic Building3
08/15/2026B01364611-I1Open ↗
08/13/2026B01245059-I1Open ↗
08/13/2026B01245084-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/15/2026B01364611-I1Open ↗