← Back
Predominantly retail with other uses
187 ATLANTIC AVENUE
BROOKLYN · BIN 3002768
💬 Discuss this project
1860Year Built
4Stories
K4Building Class
R6Zoning
6,600 sfGross Floor Area
5Units
Rent Stabilized1 Open Violation ▸FDNY Report ↗
Predominantly retail with other uses · Owner of record: RAC REALTY LLC · 2,000 sf lot · 3.3 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Roof1p · 1 filing · 6 docs
Floor 43p · 2 filings · 10 docs
Floor 34p · 3 filings · 15 docs
Floor 24p · 3 filings · 15 docs
Floor 12p · 1 filing · 4 docs
Cellar2p · 1 filing · 4 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SAHADIS607/08/2026
SAHADI'S603/22/2026
OWNER OF 187 ATLANTIC103/22/2026
OWNER OF PREMISES103/22/2026
CR & R CO.103/22/2026
RAC REALTY203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RLM ENGINEERING PLLC307/07/2026
M JUST ARCHITECTURE PC110/29/2025
ROGER DE ELECTRIC CO.204/17/2025
MSM ENGINEERING SERVICES, PLLC108/21/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JUST ARCHITECTURE303/21/2026
SALAMON ENGINEERING PLLC403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PHOENIX SUTTON STR INCGeneral Contractor207/08/2026
INTER RENOVATION INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SALAMON ENGINEERING PLLC1264204/17/2025
Building Lifecycle
All (122)Filed (7)Permit Issued (3)Signed Off (2)Violation (8)Objection (72)Special Inspection (30)
07/07/2026
Filed — Alteration
Mechanical work at 2nd, 3rd, 4th floors and 3rd floor Roof indicated on drawings filed herewith No change in Use Egress or occupancy under this application
B01302616-P1
06/30/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/30/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
06/30/2026
Special inspection requirement — HVAC-R and service water heating system controls
06/30/2026
Special inspection requirement — Maintenance information
06/30/2026
Special inspection requirement — Mechanical Systems
06/30/2026
Special inspection requirement — Final
06/30/2026
Special inspection requirement — Energy Code Compliance Inspections
02/17/2026
Objection resolved — Addressed
02/17/2026
Objection resolved — Addressed
02/17/2026
Objection resolved — Addressed
02/17/2026
Objection resolved — Addressed
02/17/2026
Objection resolved — Addressed
01/27/2026
Objection raised — Plumbing
01/27/2026
Objection resolved — Addressed
01/27/2026
Objection raised — Energy
01/27/2026
Objection resolved — Addressed
01/15/2026
Objection resolved — Addressed
01/15/2026
Objection resolved — Addressed
01/15/2026
Objection resolved — Addressed
01/15/2026
Objection resolved — Addressed
01/15/2026
Objection resolved — Addressed
01/15/2026
Objection resolved — Addressed
12/10/2025
Objection resolved — Addressed
12/03/2025
Objection resolved — Addressed
12/03/2025
Objection resolved — Addressed
12/03/2025
Special inspection requirement — Wood – Seismic Resistance
12/01/2025
Objection resolved — Addressed
11/28/2025
Objection raised — Energy
11/19/2025
Objection resolved — Addressed
11/19/2025
Objection resolved — Addressed
11/19/2025
Objection resolved — Addressed
11/19/2025
Objection resolved — Addressed
11/19/2025
Objection resolved — Addressed
11/19/2025
Objection resolved — Addressed
11/19/2025
Objection resolved — Addressed
11/19/2025
Objection resolved — Addressed
11/12/2025
Objection raised — Inspections
11/12/2025
Objection raised — Scope
11/12/2025
Objection raised — Admin
11/12/2025
Objection raised — Cost
11/12/2025
Objection raised — Other
11/12/2025
Objection raised — Inspections
11/12/2025
Objection raised — Admin
11/12/2025
Objection raised — Admin
11/12/2025
Objection raised — Mechanical
11/12/2025
Objection raised — Scope
11/12/2025
Objection raised — Plumbing
11/12/2025
Objection raised — Fire_Protection
11/12/2025
Objection raised — Mechanical
11/12/2025
Objection raised — Plumbing
11/12/2025
Objection resolved — Addressed
11/12/2025
Objection resolved — Addressed
11/12/2025
Objection resolved — Addressed
11/12/2025
Objection resolved — Addressed
11/12/2025
Objection resolved — Addressed
11/12/2025
Objection resolved — Addressed
11/12/2025
Objection resolved — Addressed
11/12/2025
Objection resolved — Addressed
11/12/2025
Objection resolved — Addressed
Latest 60 of 122 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offINTER RENOVATION INC08/26/2024
DOB NOWSupported ScaffoldSigned-offPHOENIX SUTTON STR INC08/21/2024
DOB NOWSupported ScaffoldSigned-offPHOENIX SUTTON STR INC08/21/2024
BISOTISSUEDFOREMOST CONTRACTING LLC02/06/2012
BISPLISSUEDWEISS PLUMBING INC.08/23/2007
BISMHISSUEDAIRDEX08/21/2007
1 project · most recent 07/07/2026
Heating and Air Conditioning Systems Others
FiledStatusContractorScopeMake / Model / Capacity
07/07/2026——Heating and Air Conditioning Systems, Others
Heat / Cool
Daikin AHU-5, AHU-6, AHU-7 Mod. #FXAA07AAVJU 7,500 BTU · Vrf Indoor ×6
AHU-1 & AHU-2 Mod. #FXAA07AAVJU 7,500 BTU · Vrf Indoor ×4
AHU-10 & AHU-11 Mod #FXAA12AAVJU 12,000 BTU · Vrf Indoor ×4
AHU-3 & AHU-4 Mod #FXAA12AAVJU 12,000 BTU · Vrf Indoor ×4
FXAA12AAVJU 12,000 BTU · Vrf Indoor ×4
CU-1 Mod. #RXLA36AAVJU 39,014 BTU · Condensing Unit ×2
CU-2 Mod. #RXYA72AATJA 48,255 BTU · Vrf Outdoor ×2
CU-3 Mod. #RXLA36AAVJU 23,992 BTU · Condensing Unit ×2
Other
Captiveaire Mod. #CFA-050-CA 50 CFM · Exhaust Fan ×10
Mod. #CFA-110-CA 110 CFM · Kitchen Exhaust ×4
1 project · most recent 10/29/2025
Gas Water/Sanitary
FiledStatusContractorScope
10/29/2025——Gas, Water/Sanitary
1 project · most recent 08/21/2024
FiledStatusContractorScope
08/21/2024CompleteRICHARD NEU—
1 project · most recent 10/29/2025
Steel Wood
FiledStatusContractorScope
10/29/2025——Steel, Wood
▾Special Inspection Requirements (DOB NOW) — 32
DateRequirementInspectorRole
06/30/2026Fire-Resistant Penetrations and Joints—special
06/30/2026HVAC-R and service water piping design and insulation—energy_progress
06/30/2026HVAC-R and service water heating system controls—energy_progress
06/30/2026Maintenance information—energy_progress
06/30/2026Mechanical Systems—special
06/30/2026Final—progress
06/30/2026Energy Code Compliance Inspections—progress
12/03/2025Wood – Seismic Resistance—special
10/28/2025Structural Stability – Alterations of existing buildings—special
10/24/2025HVAC-R and service water piping design and insulation—energy_progress
10/24/2025Maintenance information—energy_progress
10/24/2025Fire-Resistant Penetrations and Joints—special
10/24/2025Energy Code Compliance Inspections—progress
10/24/2025HVAC-R and service water heating equipment—energy_progress
10/07/2025Interior lighting power—energy_progress
10/07/2025Fenestration areas—energy_progress
10/07/2025Structural Steel - Details—special
10/07/2025Insulation placement and R values—energy_progress
10/07/2025Fenestration and door U-factor and product ratings—energy_progress
10/07/2025Exterior lighting power—energy_progress
10/07/2025Fenestration air leakage—energy_progress
10/07/2025Final—progress
10/07/2025Structural Steel - Welding—special
10/07/2025Structural Steel - High Strength Bolting—special
10/07/2025Air barrier - visual inspection—energy_progress
Latest 25 of 32.
▾Documents — 63 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/24/2026B01097862-I1Request digital key ↗
08/21/2026B01070327-P1Request digital key ↗
08/21/2026B01070327-I1Request digital key ↗
Showing 3 of 7 on file for this type
▸Applications & Permits12
▸DOB NOWLPC Approval/Permit6
08/20/2026B01302616-P1Open ↗
08/20/2026B01299254-I1Open ↗
08/13/2026B01070327-I1Open ↗
Showing 3 of 6 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION3
08/03/2021320424377Open ↗
01/27/2012320424377Open ↗
12/11/2007310004759Open ↗
▸BISWORK PERMIT APPLICATION3
02/10/2012320424377Open ↗
08/23/2007310004759Open ↗
08/21/2007310004759Open ↗
▸Seals & Professional Certifications19
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/21/2026B01070327-P1Open ↗
08/21/2026B01070327-I1Open ↗
08/20/2026B01302616-I1Open ↗
Showing 3 of 7 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
01/27/2012320424377Open ↗
03/14/2008310004759Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
01/27/2012320424377Open ↗
08/09/2007310004759Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
01/27/2012320424377Open ↗
08/09/2007310004759Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026B01070327-P1Open ↗
08/30/2026B01070327-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026B01070327-P1Open ↗
08/30/2026B01070327-I1Open ↗
▸BISPC FULL REPORT1
08/09/2007310004759Open ↗
▸BISTECHNICAL REPORT: STATEMENT OF RESPONSIBILITY1
08/09/2007310004759Open ↗
▸Trade Schedules & Equipment4
▸BISSCHEDULE B - PLUMBING2
01/27/2012320424377Open ↗
12/11/2007310004759Open ↗
▸BISEQUIPMENT USE PERMITS1
03/14/2008310004759Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT1
03/14/2008310004759Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/21/2026B01070327-P1Open ↗
08/21/2026B01070327-I1Open ↗
08/20/2026B01302616-P1Open ↗
Showing 3 of 6 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
08/09/2007310004759Open ↗
01/27/2012320424377Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY1
01/27/2012320424377Open ↗
▸Approvals, Objections & Sign-offs8
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
05/23/2013320424377Open ↗
03/14/2008310004759Open ↗
03/05/2008310004759Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
01/27/2012320424377Open ↗
08/09/2007310004759Open ↗
▸BISLANDMARKS APPROVAL2
05/23/2013320424377Open ↗
09/21/2007310004759Open ↗
▸DOB NOWLandmark Approval1
08/13/2026B01299254-I1Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
01/27/2012320424377Open ↗
08/23/2007310004759Open ↗
08/21/2007310004759Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
01/27/2012320424377Open ↗