← Back
Walk-up cooperative
135 PACIFIC STREET
BROOKLYN · BIN 3002960
💬 Discuss this project
1850Year Built
4Stories
C6Building Class
R6Zoning
5,980 sfGross Floor Area
5Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Walk-up cooperative · Owner of record: PACIFIC LANDMARK CORP · 2,500 sf lot · 2.39 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Roof18p · 1 filing · 20 docs
Floor 414p · 1 filing · 20 docs
Floor 3
Floor 2
Floor 1
Cellar1p · 1 filing · 4 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JOHN H HATHEWAY JR., ARCHITECT605/07/2026
HRM ENGINEERING SERVICES, PC104/21/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JOHN H HATHEWAY JR ARCHITECT403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ONE CAPITAL RENOVATION COGeneral Contractor409/12/2026
GW MECHANICAL CORPPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JOHN H HATHEWAY JR., ARCH4175605/07/2026
ADS SPECIAL INSPECTIONS1270111/19/2024
JUST CONSULTING ENGINEERI5865111/19/2024
Building Lifecycle
All (69)Filed (7)Permit Issued (6)Signed Off (1)Violation (6)Inspection (5)Objection (22)Special Inspection (22)
09/10/2026
Permit issued — Mechanical Systems
B01017854-S4-MS
09/10/2026
Permit issued — General Construction
B01017854-I1-GC
07/01/2026
Objection resolved — Addressed
05/26/2026
Objection raised — Other
05/08/2026
Signed off — Alteration
Combination of apartments at the 3rd and 4th floors. Remove kitchen at 4th floor. Reconfigure bathroom, new bathroom & new laundry room at 4th floor. New hose spigot at roof.
B01017854-S1
05/07/2026
Filed — Alteration
Combination of apartments at the 3rd and 4th floors. Remove kitchen at 4th floor. Reconfigure bathroom, new bathroom & new laundry room at 4th floor. New hose spigot at roof.
B01017854-P2
04/30/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/30/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/30/2026
Special inspection requirement — Tenant Protection Plan Compliance
12/31/2025
Permit issued — Plumbing
B01017854-S1-PL
12/22/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/08/2025
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
12/02/2025
Objection resolved — Addressed
10/02/2025
Filed — Alteration
B01275764-I1
09/16/2025
Special inspection requirement — Maintenance information
John Hatheway
09/16/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
John Hatheway
09/16/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
John Hatheway
09/16/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
John Hatheway
09/16/2025
Special inspection requirement — Energy Code Compliance Inspections
John Hatheway
09/16/2025
Special inspection requirement — Final
John Hatheway
09/16/2025
Special inspection requirement — Fire-Resistance Rated Construction
John Hatheway
09/16/2025
Special inspection requirement — Air barrier - visual inspection
John Hatheway
09/16/2025
Special inspection requirement — Interior lighting power
John Hatheway
09/16/2025
Special inspection requirement — Fenestration areas
John Hatheway
09/16/2025
Special inspection requirement — Fenestration air leakage
John Hatheway
09/16/2025
Special inspection requirement — Exterior lighting power
John Hatheway
09/16/2025
Special inspection requirement — Lighting controls
John Hatheway
09/16/2025
Special inspection requirement — Insulation placement and R values
John Hatheway
09/16/2025
Special inspection requirement — Lighting in dwelling units
John Hatheway
07/23/2025
Objection resolved — Addressed
07/23/2025
Objection resolved — Addressed
06/25/2025
Objection resolved — Addressed
06/18/2025
Objection raised — Admin
06/10/2025
Violation issued (HPD, closed)
A
06/05/2025
Objection resolved — Addressed
05/22/2025
Objection resolved — Addressed
05/13/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/06/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
John Hatheway
05/06/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
John Hatheway
05/06/2025
Special inspection requirement — Energy Code Compliance Inspections
John Hatheway
04/29/2025
Filed — Alteration
Combination of apartments at the 3rd and 4th floors. Remove kitchen at 4th floor. Reconfigure bathroom, new bathroom & new laundry room at 4th floor. New hose spigot at roof.
B01017854-P1
04/28/2025
Objection raised — Zoning
04/28/2025
Objection raised — Mechanical
04/28/2025
Objection raised — Mechanical
04/28/2025
Objection raised — Fire_Protection
04/28/2025
Objection raised — Scope
04/21/2025
Filed — Alteration
Combination of apartments at the 3rd and 4th floors. Remove kitchen at 4th floor. Reconfigure bathroom, new bathroom & new laundry room at 4th floor. New hose spigot at roof.
B01017854-S4
04/21/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
John Hatheway
04/21/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
John Hatheway
04/21/2025
Special inspection requirement — Energy Code Compliance Inspections
John Hatheway
01/29/2025
Permit issued — Plumbing
B01017854-S1-PL
12/06/2024
Permit issued — Structural
B01017854-S2-ST
11/19/2024
Filed — Alteration
Combination of apartments at the 3rd and 4th floors. Remove kitchen at 4th floor. Reconfigure bathroom, new bathroom & new laundry room at 4th floor. New hose spigot at roof.
B01017854-S2
10/28/2024
Permit issued — General Construction
B01017854-I1-GC
10/17/2024
Objection raised — Other
10/17/2024
Objection resolved — Addressed
10/17/2024
Objection raised — Fire_Protection
10/17/2024
Objection resolved — Addressed
10/15/2024
Filed — Alteration
Combination of apartments at the 3rd and 4th floors. Remove kitchen at 4th floor. Reconfigure bathroom, new bathroom & new laundry room at 4th floor. New hose spigot at roof.
B01017854-S1
09/18/2024
Objection resolved — Addressed
Latest 60 of 69 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offONE CAPITAL RENOVATION CO09/10/2026
DOB NOWGeneral ConstructionSigned-offONE CAPITAL RENOVATION CO09/10/2026
DOB NOWPlumbingSigned-offGW MECHANICAL CORP12/31/2025
DOB NOWPlumbingSigned-offGW MECHANICAL CORP01/29/2025
DOB NOWStructuralPermit IssuedONE CAPITAL RENOVATION CO12/06/2024
DOB NOWGeneral ConstructionSigned-offONE CAPITAL RENOVATION CO10/28/2024
BISOTISSUEDLAPIETRA CONTRACTING CORP03/30/2016
1 project · most recent 05/07/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
05/07/2026Signed-offONE CAPITAL RENOVATION COHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MXZ-SM48NAMHZ2 4 tons · Heat Pump Outdoor ×1
Ventilation
Greenheck SP-LP0511 35 CFM · Exhaust Fan ×2
1 project · most recent 05/07/2026
Gas Water/Sanitary
FiledStatusContractorScope
05/07/2026Signed-offGW MECHANICAL CORPGas, Water/Sanitary
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
04/30/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
04/30/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
12/22/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/08/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
05/13/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 22
DateRequirementInspectorRole
04/30/2026Tenant Protection Plan Compliance—special
09/16/2025Maintenance informationJohn Hathewayenergy_progress
09/16/2025Fenestration and door U-factor and product ratingsJohn Hathewayenergy_progress
09/16/2025Fire-Resistant Penetrations and JointsJohn Hathewayspecial
09/16/2025Structural Stability – Alterations of existing buildingsJohn Hathewayspecial
09/16/2025Energy Code Compliance InspectionsJohn Hathewayprogress
09/16/2025FinalJohn Hathewayprogress
09/16/2025Fire-Resistance Rated ConstructionJohn Hathewayprogress
09/16/2025Air barrier - visual inspectionJohn Hathewayenergy_progress
09/16/2025Interior lighting powerJohn Hathewayenergy_progress
09/16/2025Fenestration areasJohn Hathewayenergy_progress
09/16/2025Fenestration air leakageJohn Hathewayenergy_progress
09/16/2025Exterior lighting powerJohn Hathewayenergy_progress
09/16/2025Lighting controlsJohn Hathewayenergy_progress
09/16/2025Insulation placement and R valuesJohn Hathewayenergy_progress
09/16/2025Lighting in dwelling unitsJohn Hathewayenergy_progress
05/06/2025HVAC-R and service water piping design and insulationJohn Hathewayenergy_progress
05/06/2025Fire-Resistant Penetrations and JointsJohn Hathewayspecial
05/06/2025Energy Code Compliance InspectionsJohn Hathewayprogress
04/21/2025Fire-Resistant Penetrations and JointsJohn Hathewayspecial
04/21/2025HVAC-R and service water piping design and insulationJohn Hathewayenergy_progress
04/21/2025Energy Code Compliance InspectionsJohn Hathewayprogress
▾Documents — 55 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/20/2026B01275764-I1Request digital key ↗
08/17/2026B01017854-S2Request digital key ↗
08/17/2026B01017854-S4Request digital key ↗
Showing 3 of 7 on file for this type
▸Applications & Permits9
▸DOB NOWLPC Approval/Permit7
08/13/2026B01017854-S4Open ↗
08/13/2026B01017854-I1Open ↗
08/13/2026B01017854-S1Open ↗
Showing 3 of 7 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION1
09/25/2015321240322Open ↗
▸BISWORK PERMIT APPLICATION1
04/06/2016321240322Open ↗
▸Seals & Professional Certifications29
▸DOB NOWProgress Inspector Seal & Signature17
09/23/2026B01017854-S1Open ↗
09/23/2026B01017854-S1Open ↗
09/01/2026B01017854-P2Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/20/2026B01275764-I1Open ↗
08/17/2026B01017854-S2Open ↗
08/17/2026B01017854-S4Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/23/2026B01017854-S1Open ↗
09/01/2026B01017854-P2Open ↗
09/01/2026B01017854-P2Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
09/25/2015321240322Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
09/25/2015321240322Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form4
08/17/2026B01017854-S1Open ↗
08/17/2026B01017854-S2Open ↗
08/17/2026B01017854-S4Open ↗
Showing 3 of 4 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
09/25/2015321240322Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/20/2026B01275764-I1Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
09/25/2015321240322Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
09/25/2015321240322Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
09/25/2015321240322Open ↗