← Back
Five to six families
Fac Renaissance
445 BALTIC STREET · BIN 3006362
💬 Discuss this project
1900Year Built
4Stories
C2Building Class
M1-4/R6AZoning
4,800 sfGross Floor Area
5Units
Rent Stabilized1 Open Violation ▸
Five to six families · Owner of record: FAC RENAISSANCE HOUSING DEVELOPMENT FUND CORP. · 1,600 sf lot · 3 FAR built · Flood zone X500
Locations of Work
StructuralMechanicalPlumbingGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction4p · 3 filings · 20 docs
CellarUnder Construction2p · 1 filing · 8 docs
1 job · most recent 09/09/2026
Generators
FiledStatusContractorScopeMake / Model / Capacity
09/09/2026Permit IssuedFAST TRACK ELECTRIC CORPGenerators
Generators
Kohler KG50 50 kW · Generator ×2
1 job · most recent 09/09/2026
Gas
FiledStatusContractorScope
09/09/2026Permit IssuedTIDAL PLUMBING & HTG LLCGas
1 job · most recent 01/30/2026
FiledStatusContractorScope
01/30/2026Permit IssuedTRINCITY ELECTRIC, INC1 meters, 1 new_meters
Building Lifecycle
All (77)Filed (5)Permit Issued (4)Signed Off (1)Violation (36)Inspection (1)Objection (24)Special Inspection (6)
09/09/2026
Filed — Alteration
NEW INSTALLATION OF 50KW NATURAL GAS GENERATOR ON EQUIPMENT PLATFORM EXTENSION WITH RELATED GAS PIPING MODIFICATIONS FILED UNDER DOB APPLICATION NO. B00674888. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B00674884-P2
09/09/2026
Filed — Alteration
REPLACE AND RE-ROUTE EXSITING GAS PIPING SYSTEM AT CELLAR LEVEL AND BUILDING EXTERIOR TO ROOF IN SERVICE OF NEW GENERATOR INSTALLATION FILED UNDER DOB APPLICATION #B00674884. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B00674888-P1
06/26/2026
Special inspection requirement — Mechanical Systems
Ekata Shah
06/26/2026
Special inspection requirement — Final
Ekata Shah
05/27/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ekata Shah
05/13/2026
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
05/01/2026
Violation issued (HPD, closed)
A
01/14/2026
Permit issued — Plumbing
B00674888-I1-PL
12/10/2025
Permit issued — Mechanical Systems
B00674884-I1-MS
10/29/2025
Violation issued (HPD, closed)
B
03/05/2025
Signed off — Alteration
B00596702-I1
04/09/2024
Violation issued (HPD, closed)
A
07/27/2023
Violation issued (HPD, open)
B
11/09/2022
Violation issued (HPD, closed)
I
08/14/2022
Permit issued — Mechanical Systems
B00674884-I1-MS
08/04/2022
Objection resolved — Addressed
08/04/2022
Objection resolved — Addressed
07/28/2022
Objection resolved — Addressed
07/28/2022
Objection resolved — Addressed
07/28/2022
Objection resolved — Addressed
07/28/2022
Objection resolved — Addressed
07/28/2022
Objection resolved — Addressed
07/28/2022
Objection resolved — Addressed
07/28/2022
Objection resolved — Addressed
07/08/2022
Objection resolved — Addressed
07/08/2022
Objection resolved — Addressed
07/08/2022
Objection resolved — Addressed
07/05/2022
Objection raised — Mechanical
07/05/2022
Objection raised — Fire_Protection
07/05/2022
Objection raised — Inspections
07/05/2022
Objection raised — Mechanical
07/05/2022
Objection raised — Scope
07/05/2022
Objection raised — Inspections
07/05/2022
Objection raised — Scope
07/05/2022
Objection raised — Fire_Protection
07/05/2022
Objection raised — Scope
07/05/2022
Objection raised — Inspections
07/05/2022
Objection raised — Scope
07/05/2022
Objection raised — Energy
06/23/2022
Filed — Alteration
NEW INSTALLATION OF 50KW NATURAL GAS GENERATOR ON EQUIPMENT PLATFORM EXTENSION WITH RELATED GAS PIPING MODIFICATIONS FILED UNDER DOB APPLICATION NO. B00674888. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B00674884-I1
06/23/2022
Filed — Alteration
REPLACE AND RE-ROUTE EXSITING GAS PIPING SYSTEM AT CELLAR LEVEL AND BUILDING EXTERIOR TO ROOF IN SERVICE OF NEW GENERATOR INSTALLATION FILED UNDER DOB APPLICATION #B00674884. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B00674888-I1
05/17/2022
Permit issued — Antenna
B00596702-I1-AN
04/19/2022
Filed — Alteration
B00596702-I1
02/23/2022
Violation issued (HPD, closed)
A
02/04/2022
Special inspection requirement — Mechanical Systems
Ekata Shah
02/04/2022
Special inspection requirement — Final
Ekata Shah
02/04/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ekata Shah
04/22/2019
Violation issued (HPD, closed)
B
04/22/2019
Violation issued (HPD, closed)
A
04/22/2019
Violation issued (HPD, closed)
B
04/22/2019
Violation issued (HPD, closed)
B
08/09/2017
Violation issued (HPD, closed)
B
04/17/2017
Violation issued (HPD, closed)
B
11/04/2016
Violation issued (HPD, closed)
I
10/07/2015
Violation issued (HPD, closed)
I
12/14/2014
Violation issued (HPD, closed)
B
09/12/2014
Violation issued (HPD, closed)
C
11/26/2013
Violation issued (HPD, closed)
B
05/31/2013
Violation issued (HPD, closed)
B
05/31/2013
Violation issued (HPD, closed)
B
Latest 60 of 77 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
FAC RENAISSANCE HOUSING DEVELOPMENT FUND CORP.103/22/2026
ADVANCED CONSTRUCTION EQUIPMENT103/21/2026
FAC RENAISSANCE HDFC203/21/2026
CITY OF NEW YORK HPD103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KMB DESIGN GROUP, LLC509/09/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CONSTRUCTION PERMIT SERVICES303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LIVOTI ENTERPRISE LLCGeneral Contractor303/21/2026
DONALD WHITEElectrical103/21/2026
WHITE, DONALDElectrical103/21/2026
FAST TRACK ELECTRIC CORPGeneral Contractor104/09/2026
ODYSSIA GLOBAL COMM. CORPGeneral Contractor107/08/2026
TIDAL PLUMBING & HTG LLCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
KMB DESIGN GROUP, LLC513509/09/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedTIDAL PLUMBING & HTG LLC01/14/2026
DOB NOWMechanical SystemsPermit IssuedFAST TRACK ELECTRIC12/10/2025
DOB NOWMechanical SystemsPermit IssuedODYSSIA GLOBAL COMM. CORP08/14/2022
DOB NOWAntennaSigned-offLIVOTI ENTERPRISE LLC05/17/2022
BISMHISSUEDAVANTE CONTRACTING CORP05/22/2018
BISOTISSUEDAVANTE CONTRACTING CORP05/22/2018
BISPLISSUEDKATAN P & H INC02/06/2018
BISPLISSUEDAURA PLUMBING INC12/14/2017
BISMHISSUEDSQUAN CONSTRUCTION SERVIC06/02/2017
BISOTISSUEDAVANTE CONTRACTING CORP04/07/2017
BISMHISSUEDAVANTE CONTRACTING CORP04/07/2017
BISPLISSUEDSMART PLBG & HTG CORP09/13/2016
BISPLISSUEDBUDGET PLBG & HTG LLC08/16/2016
BISPLISSUEDAPEC CORP06/30/2016
BISEQISSUEDADVANCED CONSTRUCTION EQUIPMENT06/21/2016
BISOTISSUEDAVANTE CONTRACTING CORP06/15/2016
BISMHISSUEDAVANTE CONTRACTING CORP06/15/2016
BISOTISSUEDSQUAN CONSTRUCTION SERVIC06/02/2016
BISMHISSUEDSQUAN CONSTRUCTION SERVIC06/02/2016
BIS—ISSUEDVERTEX RESTORATION CORP04/02/1997
BISPLISSUEDS & L PLUMBING INC11/12/1996
BIS—ISSUEDVERTEX RESTORATION CORP07/08/1996
BISOTISSUEDS Z CONSTRUCTION CO., INC.03/17/1995
BISFBISSUEDBONAFIDE FUEL OIL CO., INC.12/27/1990
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
05/13/2026Pass-Final PL - Up to 9 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
06/26/2026Mechanical SystemsEkata Shahspecial
06/26/2026FinalEkata Shahprogress
05/27/2026Fire-Resistant Penetrations and JointsEkata Shahspecial
02/04/2022Mechanical SystemsEkata Shahspecial
02/04/2022FinalEkata Shahprogress
02/04/2022Fire-Resistant Penetrations and JointsEkata Shahspecial
▾Documents — 135 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/29/2026B00596702-I1Request digital key ↗
08/29/2026B00674884-P2Request digital key ↗
08/29/2026B00674888-P1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits22
▸BISWORK PERMIT APPLICATION14
05/23/2018321315787Open ↗
05/23/2018321315787Open ↗
02/06/2018321315787Open ↗
Showing 3 of 14 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION6
07/05/2019321315787Open ↗
06/20/2016340393684Open ↗
02/25/2016321315787Open ↗
Showing 3 of 6 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION2
06/25/2019321315787Open ↗
06/25/2019321315787Open ↗
▸Seals & Professional Certifications38
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION21
09/24/2019321315787Open ↗
09/14/2019321315787Open ↗
09/14/2019321315787Open ↗
Showing 3 of 21 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/29/2026B00596702-I1Open ↗
08/29/2026B00674884-P2Open ↗
08/29/2026B00674888-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/02/2026B00674888-P1Open ↗
09/01/2026B00674884-P2Open ↗
08/23/2026B00674884-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT3
06/20/2016340393684Open ↗
02/25/2016321315787Open ↗
02/25/2016321315787Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026B00674884-P2Open ↗
08/23/2026B00674884-I1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
02/25/2016321315787Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
06/20/2016340393684Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
06/20/2016340393684Open ↗
▸Trade Schedules & Equipment5
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE3
07/05/2019321315787Open ↗
02/25/2016321315787Open ↗
02/18/2016321307448Open ↗
▸BISPLUMBING - SUPPORTING DOCUMENTATION1
02/06/2018321315787Open ↗
▸BISFA - FDNY APPROVAL : FD-FAA1
04/14/2016321307448Open ↗
▸Safety & Tenant Protection5
▸BISTenant Protection Plan and Notes5
05/11/2018321307527Open ↗
06/02/2016321307527Open ↗
04/14/2016321307448Open ↗
Showing 3 of 5 on file for this type
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/29/2026B00596702-I1Open ↗
08/29/2026B00674884-P2Open ↗
08/29/2026B00674888-P1Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)3
02/25/2016321315787Open ↗
02/18/2016321307448Open ↗
02/17/2016321307527Open ↗
▸Energy Compliance13
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS9
09/24/2019321315787Open ↗
09/14/2019321315787Open ↗
09/14/2019321315787Open ↗
Showing 3 of 9 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS3
09/14/2019321315787Open ↗
05/11/2018321307527Open ↗
05/09/2018321307448Open ↗
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING1
06/20/2016340393684Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
06/20/2016340393684Open ↗
▸Approvals, Objections & Sign-offs15
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST9
09/24/2019321315787Open ↗
09/14/2019321315787Open ↗
05/14/2019340393684Open ↗
Showing 3 of 9 on file for this type
▸BISADMINISTRATIVE OBJECTIONS2
02/25/2016321315787Open ↗
02/17/2016321307527Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION2
12/26/2017321307448Open ↗
02/25/2016321315787Open ↗
▸BISSUPERSEDING LETTER2
02/06/2018321315787Open ↗
08/30/2016321307448Open ↗
▸Cost, Insurance & Ownership7
▸BISCOST AFFIDAVIT7
09/24/2019321315787Open ↗
09/14/2019321315787Open ↗
05/09/2018321307448Open ↗
Showing 3 of 7 on file for this type
▸Filing & Intake Forms15
▸BISBOROUGH INTAKE FORM9
09/24/2019321315787Open ↗
09/14/2019321315787Open ↗
05/14/2019340393684Open ↗
Showing 3 of 9 on file for this type
▸BISEFILING COVER SHEET4
02/24/2016321315787Open ↗
02/24/2016321315787Open ↗
02/17/2016321307527Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET1
06/20/2016340393684Open ↗
▸BISADDITIONAL INFORMATION1
06/09/2017321315787Open ↗
▸Other Documents1
▸BISFEE EXEMPTION DOCUMENTATION1
06/20/2016340393684Open ↗