← Back
Four families
846 46 STREET
BROOKLYN · BIN 3012113
💬 Discuss this project
1927Year Built
2Stories
C3Building Class
R6Zoning
2,944 sfGross Floor Area
4Units
Rent Stabilized1 Open Violation ▸FDNY Report ↗
Four families · Owner of record: JUNYUE ALEX WU AND SHUFEN CHEN IRREVOCAB LE TRUST · 2,671 sf lot · 1.1 FAR built · Flood zone X
Locations of Work
Architecture
Floor 21p · 1 filing · 14 docs
Floor 1
1 job · most recent 11/12/2021
General Wiring
FiledStatusContractorScope
11/12/2021CompleteINTELOGIC ELECTRIC, INC.General Wiring
Building Lifecycle
All (34)Filed (3)Permit Issued (2)Signed Off (2)Violation (9)Inspection (7)Objection (2)Special Inspection (9)
05/01/2026
Violation issued (HPD, open)
A
11/19/2025
Violation issued (HPD, closed)
I
04/08/2024
Violation issued (HPD, closed)
A
03/20/2023
Violation issued (HPD, closed)
A
11/10/2022
Violation issued (HPD, closed)
I
06/09/2022
Signed off — Alteration
INTERIOR RENOVATION OF EXISTING TWO STORY BRICK BUILDING. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
B00621290-I1
06/03/2022
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
05/26/2022
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
05/05/2022
Signed off — Alteration
INSTALL(1)FLOOR DRAIN,(1)WASHER MACHINE,(1)SLOP SINK,(4)BOILER AND(4)H.W.H.. RELOCATE(1)LAVATORY AND(1)WATER CLOSET IN CELLAR.RELOCATE(2)SHOWER,(2)LAVATORY,(2)WATER CLOSET,(2)SINK AND(2)STOVE AT 1ST FL AND 2ND FL. INSTALL (1) AREA DRAIN AT OPEN SPACE.
B00627140-I1
04/29/2022
Special inspection requirement — Concrete - Cast-In-Place
KON LEE
04/29/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
KON LEE
04/29/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
KON LEE
04/29/2022
Special inspection requirement — Energy Code Compliance Inspections
KON LEE
04/29/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
KON LEE
04/29/2022
Special inspection requirement — Fenestration areas
KON LEE
04/29/2022
Special inspection requirement — Fenestration air leakage
KON LEE
04/28/2022
Objection raised — Scope
04/28/2022
Objection resolved — Addressed
04/27/2022
Filed — Alteration
INTERIOR RENOVATION OF EXISTING TWO STORY BRICK BUILDING. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
B00621290-P1
02/22/2022
Violation issued (HPD, closed)
A
02/09/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
02/09/2022
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
02/09/2022
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
02/09/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/09/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/23/2021
Permit issued — Plumbing
B00627140-I1-PL
11/17/2021
Filed — Alteration
INSTALL(1)FLOOR DRAIN,(1)WASHER MACHINE,(1)SLOP SINK,(4)BOILER AND(4)H.W.H.. RELOCATE(1)LAVATORY AND(1)WATER CLOSET IN CELLAR.RELOCATE(2)SHOWER,(2)LAVATORY,(2)WATER CLOSET,(2)SINK AND(2)STOVE AT 1ST FL AND 2ND FL. INSTALL (1) AREA DRAIN AT OPEN SPACE.
B00627140-I1
11/16/2021
Permit issued — General Construction
B00621290-I1-GC
11/16/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
KON LEE
11/16/2021
Special inspection requirement — Energy Code Compliance Inspections
KON LEE
11/09/2021
Filed — Alteration
INTERIOR RENOVATION OF EXISTING TWO STORY BRICK BUILDING. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
B00621290-I1
04/06/2021
Violation issued (HPD, closed)
A
04/06/2021
Violation issued (HPD, closed)
I
11/16/2017
Violation issued (HPD, closed)
I
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
JUNYUE ALEX WU AND SHUFEN CHEN IRREVOCAB LE TRUST103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KOH HO LEE CONSULTING ENGINEER304/27/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KON HO LEE CONSULTING ENGINEER PLL603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
INTELOGIC ELECTRIC, INC.Electrical103/22/2026
GENESIS NYC CONSTRUCTIONGeneral Contractor107/08/2026
AMC PLBG, HTG & CLNG, INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
KON HO LEE CONSULTING ENG6504304/27/2022
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offAMC PLBG, HTG & CLNG, INC11/23/2021
DOB NOWGeneral ConstructionSigned-offGENESIS NYC CONSTRUCTION11/16/2021
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
06/03/2022Pass-Final General Construction Non-Directive 14PassView ↗
05/26/2022Fail-Final General Construction Non-Directive 14FailView ↗
02/09/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
02/09/2022Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
02/09/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
02/09/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/09/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
04/29/2022Concrete - Cast-In-PlaceKON LEEspecial
04/29/2022Structural Stability – Alterations of existing buildingsKON LEEspecial
04/29/2022Fire-Resistant Penetrations and JointsKON LEEspecial
04/29/2022Energy Code Compliance InspectionsKON LEEprogress
04/29/2022Fenestration and door U-factor and product ratingsKON LEEenergy_progress
04/29/2022Fenestration areasKON LEEenergy_progress
04/29/2022Fenestration air leakageKON LEEenergy_progress
11/16/2021Fire-Resistant Penetrations and JointsKON LEEspecial
11/16/2021Energy Code Compliance InspectionsKON LEEprogress
▾Documents — 19 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/31/2026B00621290-I1Request digital key ↗
08/31/2026B00627140-I1Request digital key ↗
08/15/2026B00621290-P1Request digital key ↗
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature5
08/30/2026B00627140-I1Open ↗
08/26/2026B00621290-I1Open ↗
08/26/2026B00621290-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/30/2026B00627140-I1Open ↗
08/26/2026B00621290-I1Open ↗
08/26/2026B00621290-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/31/2026B00621290-P1Open ↗
08/31/2026B00621290-I1Open ↗
08/13/2026B00627140-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/31/2026B00621290-I1Open ↗
08/15/2026B00621290-P1Open ↗
08/13/2026B00627140-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026B00621290-I1Open ↗