← Back
One story retail building
5019 5 AVENUE
BROOKLYN · BIN 3013302
💬 Discuss this project
1931Year Built
1Stories
K1Building Class
C4-3AZoning
2,425 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
One story retail building · Owner of record: 5019 5TH AVE BKLYN LLC · 2,500 sf lot · 0.97 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanical
Roof2p · 2 filings · 19 docs
Floor 124p · 3 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
6 MURRAY1607/08/2026
LAKEVIEW CONSTRUCTION103/22/2026
T-MOBILE103/22/2026
5019 5TH AVE BROOKLYN403/21/2026
5019 5TH AVE LLC BKLYN203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CARUSO TURLEY SCOTT, INC101/31/2025
RUSSELL M. BAUMANN, ARCHITECT101/30/2025
DENNIS J. LEWIS PE101/30/2025
SHAABAN ENGINEERING, LLC204/28/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NATIONAL MAINTENANCE403/21/2026
JAM CONSULTANTS, INC.603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LAKEVIEW CONSTRUCTION INC.General Contractor507/08/2026
AGIR ELECTL SOLUTION INCElectrical103/22/2026
NATIONAL MAINTENANCEScaffold107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AUTOGRAPHIC CO1579101/31/2025
CATALPA SPECIAL INSPECTIO2004201/30/2025
Building Lifecycle
All (11)Filed (5)Permit Issued (4)Signed Off (1)Violation (1)
03/13/2025
Permit issued — Mechanical Systems
B01166731-I1-MS
03/11/2025
Violation issued (ECB, closed)
Construction
02/11/2025
Permit issued — General Construction
B01166719-I1-GC
02/11/2025
Permit issued — Structural
B01166726-I1-ST
01/31/2025
Filed — Alteration
T-Mobile: Structural for ceiling-suspended display elements at 1st floor as per plans filed.
B01166726-I1
01/30/2025
Filed — Alteration
T-Mobile: Mechanical modifications and installation of supplementary split-system a/c as per plans filed.
B01166731-I1
01/30/2025
Filed — Alteration
T-Mobile: General construction inclusive of partitions modifications for retail store remodel as per plans filed. No change to use, egress, or occupancy.
B01166719-I1
02/16/2023
Signed off — Alteration
ERECT ILLUMINATED ACCESSORY BUSINESS WALL SIGN FOR T-MOBILE. NO CHANGE IN USE, EGRESS OR OCCUPANCY
B00492913-I1
04/28/2021
Filed — Alteration
ERECT ILLUMINATED ACCESSORY BUSINESS WALL SIGN FOR T-MOBILE. NO CHANGE IN USE, EGRESS OR OCCUPANCY
B00492913-P1
04/26/2021
Permit issued — Sign
B00492913-I1-SG
04/09/2021
Filed — Alteration
ERECT ILLUMINATED ACCESSORY BUSINESS WALL SIGN FOR T-MOBILE. NO CHANGE IN USE, EGRESS OR OCCUPANCY
B00492913-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedLAKEVIEW CONSTRUCTION03/13/2025
DOB NOWGeneral ConstructionPermit IssuedLAKEVIEW CONSTRUCTION02/11/2025
DOB NOWStructuralPermit IssuedLAKEVIEW CONSTRUCTION02/11/2025
DOB NOWSignSigned-offNATIONAL MAINTENANCE, INC04/26/2021
BISMHISSUEDAFGO MECHANICAL SVCS INC04/03/2018
BIS—ISSUEDTRU-ART SIGN CO INC12/18/2006
BISOTISSUEDSCHIMENTI CONSTRUCTION CO07/14/2006
BISMHISSUEDSCHIMENTI CONSTRUCTION CO07/14/2006
BISOTISSUEDHD GLASS INC05/08/2002
BISEQISSUEDHD GLASS INC05/08/2002
1 project · most recent 01/30/2025
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
01/30/2025Permit IssuedLAKEVIEW CONSTRUCTION INCAir Conditioning Systems
Cooling
Mitsubishi Electric PUYA18NHA6 18,000 BTU · Condensing Unit ×1
3 projects · most recent 02/06/2025
General Wiring
FiledStatusContractorScope
02/06/2025CompleteMAN ELECTRIC, INCGeneral Wiring
05/19/2021Permit IssuedNATIONAL MAINT. INC—
06/29/2020CompleteAGIR ELECTL SOLUTION INCGeneral Wiring
1 project · most recent 01/31/2025
Steel
FiledStatusContractorScope
01/31/2025Permit IssuedLAKEVIEW CONSTRUCTION INCSteel
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
01/30/2025Structural Cold-Formed Steelasghar Ghodsispecial
01/30/2025Structural Steel - Detailsasghar Ghodsispecial
01/29/2025Interior lighting powerERIC BERLENTenergy_progress
01/29/2025Lighting controlsERIC BERLENTenergy_progress
01/28/2025Energy Code Compliance InspectionsERIC BERLENTprogress
01/28/2025HVAC-R and service water heating equipmentERIC BERLENTenergy_progress
01/28/2025Maintenance informationERIC BERLENTenergy_progress
01/28/2025HVAC-R and service water piping design and insulationERIC BERLENTenergy_progress
01/28/2025HVAC-R and service water heating system controlsERIC BERLENTenergy_progress
01/27/2025Energy Code Compliance InspectionsERIC BERLENTprogress
01/27/2025Post-installed Anchorsasghar Ghodsispecial
01/27/2025Concrete - Cast-In-PlaceERIC BERLENTspecial
01/27/2025Fire-Resistant Penetrations and JointsERIC BERLENTspecial
01/14/2025FinalERIC BERLENTprogress
01/14/2025Mechanical SystemsERIC BERLENTspecial
01/14/2025FinalERIC BERLENTprogress
01/14/2025FinalERIC BERLENTprogress
04/15/2021FinalAHMED SHAABANprogress
▾Documents — 51 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
09/01/2026B00492913-P1Request digital key ↗
09/01/2026B00492913-I1Request digital key ↗
08/23/2026B01166719-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
03/09/2018340576184Open ↗
▸BISWORK PERMIT APPLICATION1
03/09/2018340576184Open ↗
▸Seals & Professional Certifications27
▸DOB NOWProgress Inspector Seal & Signature12
08/27/2026B00492913-P1Open ↗
08/23/2026B01166719-I1Open ↗
08/23/2026B01166719-I1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
08/23/2026B01166719-I1Open ↗
08/23/2026B01166719-I1Open ↗
08/22/2026B01166726-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
09/01/2026B00492913-P1Open ↗
09/01/2026B00492913-I1Open ↗
08/23/2026B01166719-I1Open ↗
Showing 3 of 5 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
03/09/2018340576184Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
03/09/2018340576184Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
03/09/2018340576184Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
08/01/2018340576184Open ↗
▸Trade Schedules & Equipment2
▸BISEQUIPMENT USE PERMITS1
08/01/2018340576184Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT1
08/01/2018340576184Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
09/01/2026B00492913-I1Open ↗
09/01/2026B00492913-P1Open ↗
08/23/2026B01166719-I1Open ↗
Showing 3 of 5 on file for this type
▸Energy Compliance4
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
03/09/2018340576184Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
08/01/2018340576184Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
03/09/2018340576184Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
08/01/2018340576184Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
03/09/2018340576184Open ↗
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
08/01/2018340576184Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
08/01/2018340576184Open ↗
03/09/2018340576184Open ↗
▸Filing & Intake Forms2
▸BISBOROUGH INTAKE FORM1
08/01/2018340576184Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
03/09/2018340576184Open ↗