← Back
One family attached or semi-detached
714 54 STREET
BROOKLYN · BIN 3014791
💬 Discuss this project
1930Year Built
2Stories
A5Building Class
R6BZoning
1,176 sfGross Floor Area
1Units
One family attached or semi-detached · 1,377 sf lot · 0.85 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbing
Floor 24p · 1 filing · 20 docs
Floor 1
Cellar1p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LU ENGINEERING SERVICE PC407/24/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
H Z BUILDING NY803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
WING TAI CONSTRUCTION INCGeneral Contractor303/21/2026
CATMAN PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
LU ENGINEERING SERVICE PC6575407/24/2024
Building Lifecycle
All (28)Filed (4)Permit Issued (2)Signed Off (2)Inspection (5)Objection (6)Special Inspection (9)
08/22/2024
Signed off — Alteration
INTERIOR RENOVATION ON CEL, 1ST, 2ND FLOOR, REPAIRING PARTITION, FLOORING AND CEILING. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00997764-S1
08/20/2024
Signed off — Alteration
INTERIOR RENOVATION ON CEL, 1ST, 2ND FLOOR, REPAIRING PARTITION, FLOORING AND CEILING. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00997764-I1
08/12/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
07/29/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
DONGSHENG LU
07/29/2024
Special inspection requirement — Energy Code Compliance Inspections
DONGSHENG LU
07/29/2024
Special inspection requirement — Fire-Resistance Rated Construction
DONGSHENG LU
07/29/2024
Special inspection requirement — Interior lighting power
DONGSHENG LU
07/25/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/24/2024
Filed — Alteration
INTERIOR RENOVATION ON CEL, 1ST, 2ND FLOOR, REPAIRING PARTITION, FLOORING AND CEILING. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00997764-P2
07/23/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/19/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
DONGSHENG LU
07/19/2024
Special inspection requirement — Energy Code Compliance Inspections
DONGSHENG LU
07/19/2024
Special inspection requirement — Fire-Resistance Rated Construction
DONGSHENG LU
07/19/2024
Special inspection requirement — Interior lighting power
DONGSHENG LU
05/31/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
05/31/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/24/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
DONGSHENG LU
05/22/2024
Filed — Alteration
INTERIOR RENOVATION ON CEL, 1ST, 2ND FLOOR, REPAIRING PARTITION, FLOORING AND CEILING. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00997764-P1
03/21/2024
Permit issued — Plumbing
B00997764-S1-PL
03/20/2024
Permit issued — General Construction
B00997764-I1-GC
03/11/2024
Filed — Alteration
INTERIOR RENOVATION ON CEL, 1ST, 2ND FLOOR, REPAIRING PARTITION, FLOORING AND CEILING. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00997764-S1
03/11/2024
Objection raised — Scope
03/11/2024
Objection resolved — Addressed
03/11/2024
Objection raised — Scope
03/11/2024
Objection resolved — Addressed
03/11/2024
Objection raised — Scope
03/11/2024
Objection resolved — Addressed
02/29/2024
Filed — Alteration
INTERIOR RENOVATION ON CEL, 1ST, 2ND FLOOR, REPAIRING PARTITION, FLOORING AND CEILING. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00997764-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offCATMAN PLUMBING INC03/21/2024
DOB NOWGeneral ConstructionSigned-offWING TAI CONSTRUCTION INC03/20/2024
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
08/12/2024Pass-Final General Construction Non-Directive 14PassView ↗
07/25/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/23/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
05/31/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
05/31/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
07/29/2024Fire-Resistant Penetrations and JointsDONGSHENG LUspecial
07/29/2024Energy Code Compliance InspectionsDONGSHENG LUprogress
07/29/2024Fire-Resistance Rated ConstructionDONGSHENG LUprogress
07/29/2024Interior lighting powerDONGSHENG LUenergy_progress
07/19/2024Fire-Resistant Penetrations and JointsDONGSHENG LUspecial
07/19/2024Energy Code Compliance InspectionsDONGSHENG LUprogress
07/19/2024Fire-Resistance Rated ConstructionDONGSHENG LUprogress
07/19/2024Interior lighting powerDONGSHENG LUenergy_progress
05/24/2024Fire-Resistant Penetrations and JointsDONGSHENG LUspecial
▾Documents — 21 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/25/2026B00997764-S1Request digital key ↗
08/25/2026B00997764-P2Request digital key ↗
08/25/2026B00997764-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications13
▸DOB NOWProgress Inspector Seal & Signature6
08/24/2026B00997764-P2Open ↗
08/24/2026B00997764-P2Open ↗
08/24/2026B00997764-P2Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/25/2026B00997764-S1Open ↗
08/25/2026B00997764-I1Open ↗
08/13/2026B00997764-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/21/2026B00997764-S1Open ↗
08/24/2026B00997764-P2Open ↗
08/23/2026B00997764-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/25/2026B00997764-S1Open ↗
08/25/2026B00997764-I1Open ↗
08/13/2026B00997764-P2Open ↗
Showing 3 of 4 on file for this type