← Back
Miscellaneous two family
433 56 STREET
BROOKLYN · BIN 3014989
💬 Discuss this project
1901Year Built
2Stories
B9Building Class
R6BZoning
2,928 sfGross Floor Area
2Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Miscellaneous two family · 2,037 sf lot · 1.44 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Floor 222p · 2 filings · 20 docs
Floor 122p · 2 filings · 20 docs
Cellar23p · 3 filings · 20 docs
Basement21p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
HIGH QUALITY CONSTRUCTION403/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/10/2021$1.3M—Private party → Private party$454/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NY BUILDING ASSOCIATES INC301/10/2023
J&R DESIGN AND INSPECTION CORP.407/14/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HIGHQUALITY CONSTRUCTION VNW1203/21/2026
HIGH QUALITY 338203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HIGH QUALITY CONSTRUCTIONGeneral Contractor507/08/2026
CASE PLUMBING LLCFire Protection207/08/2026
CATMAN PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244201/10/2023
J&R DESIGN AND INSPECTION6637307/14/2022
AR-TECH ENGINEERING, P.C.6659105/18/2022
Building Lifecycle
All (52)Filed (7)Permit Issued (6)Signed Off (3)Violation (7)Inspection (8)Objection (4)Special Inspection (17)
02/24/2023
Signed off — Alteration
PLUMBING AND SPRINKLER APPLICATION FILE IN CONJUNCTION WITH ALTERATION-CO JOB#B00609308-I1. PROPOSED PLUMBING AND SPRINKLER WORK ON CELLAR, BASEMENT, 1ST, AND 2ND FLOOR AS PER PLAN.
B00675820-I1
01/18/2023
Signed off — Alteration
B00690792-I1
01/18/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
01/10/2023
Filed — Alteration CO
COVERT EXISTING 2-FAMILY BUILDING TO 3-FAMILY BUILDING WITH INTERIOR PARTITIONS, DOORS, CEILING, AND FLOORING WORKS AS PER PLAN. OBTAIN NEW CERTIFICATE OF OCCUPANCY.
B00609308-P2
01/10/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
01/10/2023
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
01/10/2023
Special inspection requirement — Fire-Resistance Rated Construction
NARESH MAHANGU
01/10/2023
Special inspection requirement — Maintenance information
NARESH MAHANGU
01/10/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
NARESH MAHANGU
01/10/2023
Special inspection requirement — Interior lighting power
NARESH MAHANGU
01/09/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
01/06/2023
Signed off — Alteration
FILE STRUCTURAL WORK TYPE WITH REPLACE/NEW WOOD JOIST, BEAM AND COLUMN AS PER PLAN. THIS APPLICATION IS IN CONJUNCTION WITH GENERAL CONSTRUCTION WORK #B00609308. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00774597-I1
01/04/2023
Permit issued — Plumbing
B00675820-I1-EW-SP
01/03/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/15/2022
Permit issued — Sprinklers
B00675820-I1-EW-SP
09/04/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/04/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/01/2022
Violation issued (ECB, closed)
Construction
08/23/2022
Violation issued (ECB, closed)
Construction
08/23/2022
Violation issued (ECB, closed)
Construction
07/15/2022
Permit issued — Structural
B00774597-I1-ST
07/14/2022
Filed — Alteration
FILE STRUCTURAL WORK TYPE WITH REPLACE/NEW WOOD JOIST, BEAM AND COLUMN AS PER PLAN. THIS APPLICATION IS IN CONJUNCTION WITH GENERAL CONSTRUCTION WORK #B00609308. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00774597-I1
07/13/2022
Special inspection requirement — Structural Steel - Details
Robert Truskosky
07/13/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
Robert Truskosky
07/13/2022
Special inspection requirement — Final
Robert Truskosky
07/13/2022
Special inspection requirement — Energy Code Compliance Inspections
Robert Truskosky
07/13/2022
Special inspection requirement — Structural Wood Frame
Robert Truskosky
06/21/2022
Violation issued (ECB, closed)
Construction
06/14/2022
Objection resolved — Addressed
06/14/2022
Objection resolved — Addressed
06/07/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
06/07/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/25/2022
Objection raised — Accessibility
05/25/2022
Objection raised — Accessibility
05/24/2022
Filed — Alteration
PLUMBING AND SPRINKLER APPLICATION FILE IN CONJUNCTION WITH ALTERATION-CO JOB#B00609308-I1. PROPOSED PLUMBING AND SPRINKLER WORK ON CELLAR, BASEMENT, 1ST, AND 2ND FLOOR AS PER PLAN.
B00675820-P1
05/18/2022
Filed — Alteration CO
COVERT EXISTING 2-FAMILY BUILDING TO 3-FAMILY BUILDING WITH INTERIOR PARTITIONS, DOORS, CEILING, AND FLOORING WORKS AS PER PLAN. OBTAIN NEW CERTIFICATE OF OCCUPANCY.
B00609308-P1
05/17/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
ALBERTO ROMAN
05/17/2022
Special inspection requirement — Energy Code Compliance Inspections
ALBERTO ROMAN
05/17/2022
Special inspection requirement — Fire-Resistance Rated Construction
ALBERTO ROMAN
05/17/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
ALBERTO ROMAN
05/17/2022
Special inspection requirement — Interior lighting power
ALBERTO ROMAN
05/17/2022
Special inspection requirement — Maintenance information
ALBERTO ROMAN
05/02/2022
Violation issued (ECB, closed)
Construction
03/29/2022
Permit issued — Sprinklers
B00675820-I1-PL
03/04/2022
Permit issued — Construction Fence
B00690792-I1-FN
03/02/2022
Filed — Alteration
PLUMBING AND SPRINKLER APPLICATION FILE IN CONJUNCTION WITH ALTERATION-CO JOB#B00609308-I1. PROPOSED PLUMBING AND SPRINKLER WORK ON CELLAR, BASEMENT, 1ST, AND 2ND FLOOR AS PER PLAN.
B00675820-I1
03/02/2022
Filed — Alteration
B00690792-I1
03/01/2022
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
02/24/2022
Permit issued — General Construction
B00609308-I1-GC
01/27/2022
Filed — Alteration CO
COVERT EXISTING 2-FAMILY BUILDING TO 3-FAMILY BUILDING WITH INTERIOR PARTITIONS, DOORS, CEILING, AND FLOORING WORKS AS PER PLAN. OBTAIN NEW CERTIFICATE OF OCCUPANCY.
B00609308-I1
01/03/2022
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
12/21/2021
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offS & L PLUMBING INC01/04/2023
DOB NOWSprinklersSigned-offS & L PLUMBING INC12/15/2022
DOB NOWStructuralSigned-offHIGH QUALITY CONSTRUCTION07/15/2022
DOB NOWSprinklersSigned-offCATMAN PLUMBING INC03/29/2022
DOB NOWConstruction FenceSigned-offHIGH QUALITY CONSTRUCTION03/04/2022
DOB NOWGeneral ConstructionPermit IssuedHIGH QUALITY CONSTRUCTION02/24/2022
1 project · most recent 03/31/2022
General Wiring
FiledStatusContractorScope
03/31/2022CompleteA.C. MORGAN ELECTRICGeneral Wiring
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
01/18/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
01/09/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
01/03/2023Pass-Final CND-Occupancy InspectionPassView ↗
06/07/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/07/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/01/2022Fail-Final General Construction Non-Directive 14FailView ↗
01/03/2022Fail-Final General Construction Non-Directive 14FailView ↗
12/21/2021Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 17
DateRequirementInspectorRole
01/10/2023Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
01/10/2023Energy Code Compliance InspectionsNARESH MAHANGUprogress
01/10/2023Fire-Resistance Rated ConstructionNARESH MAHANGUprogress
01/10/2023Maintenance informationNARESH MAHANGUenergy_progress
01/10/2023HVAC-R and service water piping design and insulationNARESH MAHANGUenergy_progress
01/10/2023Interior lighting powerNARESH MAHANGUenergy_progress
07/13/2022Structural Steel - DetailsRobert Truskoskyspecial
07/13/2022Structural Stability – Alterations of existing buildingsRobert Truskoskyspecial
07/13/2022FinalRobert Truskoskyprogress
07/13/2022Energy Code Compliance InspectionsRobert Truskoskyprogress
07/13/2022Structural Wood FrameRobert Truskoskyprogress
05/17/2022Fire-Resistant Penetrations and JointsALBERTO ROMANspecial
05/17/2022Energy Code Compliance InspectionsALBERTO ROMANprogress
05/17/2022Fire-Resistance Rated ConstructionALBERTO ROMANprogress
05/17/2022HVAC-R and service water piping design and insulationALBERTO ROMANenergy_progress
05/17/2022Interior lighting powerALBERTO ROMANenergy_progress
05/17/2022Maintenance informationALBERTO ROMANenergy_progress
▾Documents — 51 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/31/2026B00675820-P1Request digital key ↗
08/31/2026B00675820-I1Request digital key ↗
08/31/2026B00690792-I1Request digital key ↗
Showing 3 of 7 on file for this type
▸Applications & Permits6
▸DOB NOWLPC Approval/Permit6
08/31/2026B00675820-I1Open ↗
08/13/2026B00609308-I1Open ↗
08/13/2026B00675820-P1Open ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications22
▸DOB NOWProgress Inspector Seal & Signature11
09/02/2026B00609308-P2Open ↗
09/02/2026B00609308-P2Open ↗
09/02/2026B00609308-P2Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/31/2026B00675820-I1Open ↗
08/13/2026B00609308-I1Open ↗
08/13/2026B00690792-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/02/2026B00609308-P2Open ↗
09/01/2026B00609308-P1Open ↗
08/26/2026B00774597-I1Open ↗
Showing 3 of 4 on file for this type
▸Safety & Tenant Protection4
▸DOB NOWStreet Tree Checklist3
08/13/2026B00609308-P1Open ↗
08/13/2026B00609308-I1Open ↗
08/13/2026B00609308-P2Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B00609308-I1Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/31/2026B00675820-I1Open ↗
08/13/2026B00609308-I1Open ↗
08/13/2026B00609308-P1Open ↗
Showing 3 of 6 on file for this type
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026B00609308-I1Open ↗
08/13/2026B00675820-I1Open ↗
▸Other Documents4
▸DOB NOWProperty Ownership Certification3
08/13/2026B00609308-P1Open ↗
08/13/2026B00609308-I1Open ↗
08/13/2026B00609308-P2Open ↗
▸DOB NOWFinal Survey1
08/13/2026B00609308-I1Open ↗