← Back
Two family converted from one family
246 7 STREET
BROOKLYN · BIN 3021807
💬 Discuss this project
1901Year Built
2Stories
B3Building Class
C4-4DZoning
1,575 sfGross Floor Area
2Units
Two family converted from one family · 1,575 sf lot · 1 FAR built · Flood zone X
Locations of Work
StructuralElectricalMechanicalPlumbingCivil
Permit Issued — active, not yet Signed-off
RoofUnder Construction6p · 2 filings · 20 docs
BulkheadUnder Construction7p · 2 filings · 20 docs
Floor 15Under Construction4p · 1 filing · 20 docs
Floor 14Under Construction3p · 1 filing · 20 docs
Floor 13Under Construction3p · 1 filing · 20 docs
Floor 12Under Construction4p · 1 filing · 20 docs
Floor 11Under Construction3p · 1 filing · 20 docs
Floor 10Under Construction1p · 1 filing · 20 docs
Floor 9Under Construction1p · 1 filing · 20 docs
Floor 8Under Construction1p · 1 filing · 20 docs
Floor 7Under Construction1p · 1 filing · 20 docs
Floor 6Under Construction1p · 1 filing · 20 docs
Floor 5Under Construction1p · 1 filing · 20 docs
Floor 4Under Construction6p · 2 filings · 20 docs
Floor 3Under Construction6p · 2 filings · 20 docs
Floor 2Under Construction6p · 2 filings · 20 docs
Floor 1Under Construction7p · 2 filings · 20 docs
CellarUnder Construction2p · 1 filing · 20 docs
1 job · most recent 06/23/2026
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
06/23/2026Permit IssuedROGERS DEVELOPERS GRP LLCAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Mitsubishi Electric PUMY-P48NKMU3 48,000 BTU · Vrf Outdoor ×2
PUHY-P60TLMU-A-BSNKMU3 60,000 BTU · Vrf Outdoor ×1
PUMY-P36NKMU3 36,000 BTU · Vrf Outdoor ×1
PUZ-A18NKA7 18,000 BTU · Condensing Unit ×1
Heating
Mitsubishi Electric PUMY-P48NKMU3 42,000 BTU · Vrf Outdoor ×2
PUHY-P60TLMU-A-BSNKMU3 65,000 BTU · Vrf Outdoor ×1
PUMY-P36NKMU3 54,000 BTU · Vrf Outdoor ×1
PUZ-A18NKA7 22,000 BTU · Condensing Unit ×1
Ventilation
Greenheck CUE-140HP-VG 1,150 CFM · Exhaust Fan ×2
SQ-97-VG 150 CFM · Exhaust Fan ×1
SQ-98-VG 250 CFM · Exhaust Fan ×1
1 job · most recent 06/23/2026
Sprinkler System
FiledStatusContractorScope
06/23/2026——Sprinkler System
1 job · most recent 06/23/2026
Storm Water/Sanitary
FiledStatusContractorScope
06/23/2026——Storm, Water/Sanitary
4 jobs · most recent 07/29/2026
General Wiring
FiledStatusContractorScope
07/29/2026Permit IssuedRICHARD NEU—
12/11/2025Permit IssuedPOWER DIRECT ELECTRIC INCGeneral Wiring
12/11/2025Permit IssuedPOWER DIRECT ELECTRIC INC88 meters, 88 new_meters
12/11/2025Permit IssuedPOWER DIRECT ELECTRIC INC1 meters, 1 new_meters
1 job · most recent 06/23/2026
Concrete
FiledStatusContractorScope
06/23/2026Permit IssuedROGERS DEVELOPERS GRP LLCConcrete
2 jobs · most recent 07/29/2026
Sidewalk Shed Fence
FiledStatusContractorScope
07/29/2026Permit IssuedPLATINUM SERVICES NY LLCSidewalk Shed
06/23/2026Permit IssuedROGERS DEVELOPERS GRP LLCFence
Building Lifecycle
All (52)Filed (10)Permit Issued (3)Objection (10)Special Inspection (29)
09/10/2026
Permit issued — Construction Fence
B01315432-S8-FN
08/24/2026
Permit issued — Construction Fence
B01363953-I1-FN
07/30/2026
Permit issued — Sidewalk Shed
B01434538-I1-SH
07/29/2026
Filed — Alteration
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF 2022 THE NYC BUILDING CODE. LIVE LOAD 300PSF.
B01434538-I1
07/09/2026
Objection raised — Other
06/23/2026
Filed — New Building
SUBSEQUENT TEMPORARY STANDPIPE APPLICATION FILED HEREWITH.
B01315432-S1
06/22/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
06/22/2026
Special inspection requirement — Construction Operations Influencing Adjacent Structures
06/22/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
06/22/2026
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
06/22/2026
Special inspection requirement — Subgrade Inspections
06/22/2026
Special inspection requirement — Structural Steel - Welding
06/22/2026
Special inspection requirement — Structural Steel - Details
06/16/2026
Objection raised — Other
06/16/2026
Objection raised — Other
06/16/2026
Objection raised — Other
05/27/2026
Filed — New Building
SUBSEQUENT TEMPORARY STANDPIPE APPLICATION FILED HEREWITH.
B01315432-S8
05/15/2026
Filed — New Building
SUBSEQUENT TEMPORARY STANDPIPE APPLICATION FILED HEREWITH.
B01315432-S2
05/15/2026
Filed — New Building
SUBSEQUENT TEMPORARY STANDPIPE APPLICATION FILED HEREWITH.
B01315432-S3
05/13/2026
Special inspection requirement — Subgrade Inspections
05/13/2026
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
05/13/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
05/11/2026
Special inspection requirement — Concrete - Cast-In-Place
05/11/2026
Special inspection requirement — Subgrade Inspections
05/11/2026
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
05/11/2026
Special inspection requirement — Construction Operations Influencing Adjacent Structures
05/11/2026
Special inspection requirement — Construction Operations Influencing Adjacent Structures
05/11/2026
Special inspection requirement — Concrete - Cast-In-Place
05/11/2026
Special inspection requirement — Deep Foundation Elements
04/13/2026
Objection raised — Other
04/08/2026
Objection raised — Other
03/31/2026
Objection resolved — Resolved
03/26/2026
Filed — New Building
SUBSEQUENT TEMPORARY STANDPIPE APPLICATION FILED HEREWITH.
B01315432-S4
03/26/2026
Filed — New Building
SUBSEQUENT TEMPORARY STANDPIPE APPLICATION FILED HEREWITH.
B01315432-S5
03/26/2026
Special inspection requirement — Post-installed Anchors
03/23/2026
Special inspection requirement — HVAC-R and service water heating equipment
03/23/2026
Special inspection requirement — Maintenance information
03/23/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
03/23/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
03/23/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/23/2026
Special inspection requirement — HVAC-R and service water heating system controls
03/20/2026
Special inspection requirement — Final
03/20/2026
Special inspection requirement — Final
03/20/2026
Special inspection requirement — Footing and Foundation
03/06/2026
Objection raised — Other
03/06/2026
Objection raised — Other
03/04/2026
Filed — Alteration
B01363953-I1
01/22/2026
Filed — New Building
SUBSEQUENT TEMPORARY STANDPIPE APPLICATION FILED HEREWITH.
B01315432-I1
01/14/2026
Objection raised — Admin
12/23/2025
Filed — Full Demolition
Full demolition of 2 story building.
B01277747-I1
12/01/2025
Special inspection requirement — Construction Operations Influencing Adjacent Structures
DUY HOANG
12/01/2025
Special inspection requirement — Structural Stability – Alterations of existing Buildings
DUY HOANG
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BRAVON CAPITAL909/15/2026
PLATINUM SERVICES NY107/31/2026
ROGERS EQUITIES203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ALWAYS FAST SERVICES CORP107/29/2026
ELEVATED ENGINEERING NYC306/23/2026
NA205/27/2026
VENTROP ENGINEERING CONSULTING GROU203/26/2026
ADROIT ENGINEERING PLLC203/04/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AVALON DESIGNS403/21/2026
EXPEDITING 4 U103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ROGERS DEVELOPERS GRP LLCGeneral Contractor209/12/2026
PLATINUM SERVICES NY LLCGeneral Contractor107/31/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ADROIT ENGINEERING PLLC8885112/23/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedROGERS DEVELOPERS GRP LLC09/10/2026
DOB NOWConstruction FencePermit IssuedROGERS DEVELOPERS GRP LLC08/24/2026
DOB NOWSidewalk ShedPermit IssuedPLATINUM SERVICES NY LLC07/30/2026
▾Special Inspection Requirements (DOB NOW) — 29
DateRequirementInspectorRole
06/22/2026Excavations - Sheeting, Shoring, and Bracing—special
06/22/2026Construction Operations Influencing Adjacent Structures—special
06/22/2026Subsurface Investigations (Borings/Test Pits)—special
06/22/2026Subsurface Conditions – Fill Placement & In-Place Density—special
06/22/2026Subgrade Inspections—special
06/22/2026Structural Steel - Welding—special
06/22/2026Structural Steel - Details—special
05/13/2026Subgrade Inspections—special
05/13/2026Subsurface Conditions – Fill Placement & In-Place Density—special
05/13/2026Subsurface Investigations (Borings/Test Pits)—special
05/11/2026Concrete - Cast-In-Place—special
05/11/2026Subgrade Inspections—special
05/11/2026Subsurface Conditions – Fill Placement & In-Place Density—special
05/11/2026Construction Operations Influencing Adjacent Structures—special
05/11/2026Construction Operations Influencing Adjacent Structures—special
05/11/2026Concrete - Cast-In-Place—special
05/11/2026Deep Foundation Elements—special
03/26/2026Post-installed Anchors—special
03/23/2026HVAC-R and service water heating equipment—energy_progress
03/23/2026Maintenance information—energy_progress
03/23/2026HVAC-R and service water piping design and insulation—energy_progress
03/23/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation—special
03/23/2026Fire-Resistant Penetrations and Joints—special
03/23/2026HVAC-R and service water heating system controls—energy_progress
03/20/2026Final—progress
Latest 25 of 29.
▾Documents — 33 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/18/2026B01363953-I1Request digital key ↗
08/17/2026B01315432-I1Request digital key ↗
08/17/2026B01315432-S8Request digital key ↗
Showing 3 of 9 on file for this type
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram2
08/17/2026B01315432-I1Open ↗
08/13/2026B01315432-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/17/2026B01315432-I1Open ↗
▸DOB NOWRestrictive Declaration/Easement 11
08/17/2026B01315432-I1Open ↗
▸DOB NOWRestrictive Declaration/Easement 21
08/17/2026B01315432-I1Open ↗
▸Seals & Professional Certifications12
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/18/2026B01363953-I1Open ↗
08/17/2026B01315432-S3Open ↗
08/17/2026B01315432-S2Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/28/2026B01277747-I1Open ↗
08/28/2026B01277747-I1Open ↗
▸Trade Schedules & Equipment1
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/17/2026B01315432-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/17/2026B01315432-I1Open ↗
▸Other Documents5
▸DOB NOWProperty Ownership Certification2
08/17/2026B01315432-I1Open ↗
08/13/2026B01277747-I1Open ↗
▸DOB NOWStructure Photographs1
08/13/2026B01277747-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026B01315432-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/17/2026B01315432-I1Open ↗