← Back
Office with apartments (no commercial)
405 5 AVENUE
BROOKLYN · BIN 3021884
💬 Discuss this project
1925Year Built
3Stories
O8Building Class
R6AZoning
—Gross Floor Area
3Units
2 Open Violations ▸FDNY Report ↗
Office with apartments (no commercial) · Owner of record: 405 5TH AVENUE LLC · 1.23 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire Protection
Roof6p · 2 filings · 18 docs
Bulkhead2p · 1 filing · 13 docs
Floor 64p · 1 filing · 13 docs
Floor 55p · 1 filing · 13 docs
Floor 44p · 1 filing · 13 docs
Floor 35p · 2 filings · 18 docs
Floor 27p · 2 filings · 18 docs
Floor 18p · 2 filings · 18 docs
Cellar5p · 2 filings · 18 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
VORG DEVELOPMENT509/18/2026
PEMA REALTY CORP203/22/2026
405 5TH AVENUE LLC103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FLORINELA MURESAN308/03/2026
ADROIT ENGINEERING PLLC207/06/2026
DXA STUDIO106/15/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BENJAMIN DREBINElectrical103/21/2026
DM80 SOLUTIONS LLCGeneral Contractor109/18/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ADROIT ENGINEERING PLLC8885103/31/2026
Building Lifecycle
All (63)Filed (6)Permit Issued (1)Violation (7)Objection (20)Special Inspection (29)
09/17/2026
Permit issued — Construction Fence
B01426479-I1-FN
08/12/2026
Objection raised — Scope
08/11/2026
Objection raised — Admin
08/11/2026
Special inspection requirement — Shutoff dampers
08/03/2026
Filed — New Building
Sprinkler work as part of construction of six story new building.
B01414331-S2
07/30/2026
Filed — New Building
Sprinkler work as part of construction of six story new building.
B01414331-S1
07/30/2026
Objection resolved — Resolved
07/14/2026
Objection raised — Scope
07/13/2026
Objection raised — Zoning
07/13/2026
Objection raised — Zoning
07/13/2026
Objection raised — Other
07/13/2026
Objection raised — Zoning
07/13/2026
Special inspection requirement — Insulation placement and R values
07/13/2026
Special inspection requirement — Fenestration areas
07/13/2026
Special inspection requirement — Air barrier - visual inspection
07/13/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
07/13/2026
Special inspection requirement — Fenestration air leakage
07/09/2026
Objection resolved — Addressed
07/09/2026
Objection resolved — Addressed
07/09/2026
Objection resolved — Addressed
07/09/2026
Objection resolved — Addressed
07/09/2026
Objection resolved — Addressed
07/06/2026
Filed — Alteration
PROPOSED 8FT CONSTRUCTION FENCE. NO CHANGE TO USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01426479-I1
07/06/2026
Objection raised — Structural
07/06/2026
Objection raised — Structural
07/06/2026
Objection raised — Fire_Protection
07/06/2026
Objection raised — Fire_Protection
07/06/2026
Objection raised — Admin
06/30/2026
Filed — New Building
Sprinkler work as part of construction of six story new building.
B01414331-S3
06/22/2026
Special inspection requirement — HVAC-R and service water heating system controls
06/22/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/22/2026
Special inspection requirement — Post-installed Anchors
06/22/2026
Special inspection requirement — Sprinkler Systems
06/22/2026
Special inspection requirement — Maintenance information
06/22/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/22/2026
Special inspection requirement — Post-installed Anchors
06/22/2026
Special inspection requirement — HVAC-R and service water heating equipment
06/22/2026
Special inspection requirement — Maintenance information
06/22/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
06/22/2026
Special inspection requirement — Final
06/22/2026
Special inspection requirement — HVAC-R and service water heating equipment
06/22/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
06/22/2026
Special inspection requirement — HVAC-R and service water heating system controls
06/22/2026
Special inspection requirement — Chimneys and vents
06/22/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/22/2026
Special inspection requirement — Heating Systems
06/22/2026
Special inspection requirement — Post-installed Anchors
06/22/2026
Special inspection requirement — Mechanical Systems
06/15/2026
Filed — New Building
Sprinkler work as part of construction of six story new building.
B01414331-I1
06/15/2026
Special inspection requirement — Fire-Resistance Rated Construction
06/15/2026
Special inspection requirement — Sprayed fire-resistant materials
06/15/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
04/28/2026
Objection resolved — Resolved
04/10/2026
Objection raised — Other
03/31/2026
Filed — Full Demolition
Full demolition to a three story building
B01380209-I1
03/30/2026
Special inspection requirement — Structural Stability – Alterations of existing Buildings
DUY HOANG
09/16/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/25/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/25/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/28/1990
Violation issued (DOB, open)
VP-VIOLATION UNSERVED ECB-ACTIVE
Latest 60 of 63 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedDM80 SOLUTIONS LLC09/17/2026
BISPLISSUEDSTEVE BELSITO SONS, INC03/15/2006
BISOTISSUEDSUNG CONSTRUCTION03/09/2006
1 project · most recent 08/03/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/03/2026——Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Lg ZRUM048GSS0 54,000 BTU · Vrf Outdoor ×8
ZRUM036GSS0 42,000 BTU · Vrf Outdoor ×5
ZRUM060GSS0 64,000 BTU · Vrf Outdoor ×5
Ventilation
Solar & Palau TRCeN500 1,200 CFM · Erv ×12
Aaon RNA-007-A-A-8-GJA0A-A02N0 75,800 BTU · Erv ×1
Renewaire LE-5XJRTVNS35GG 3,200 CFM · Erv ×1
1 project · most recent 08/03/2026
Storm Water/Sanitary
FiledStatusContractorScope
08/03/2026——Storm, Water/Sanitary
1 project · most recent 07/06/2026
Fence
FiledStatusContractorScope
07/06/2026Permit IssuedDM80 SOLUTIONS LLCFence
▾Special Inspection Requirements (DOB NOW) — 29
DateRequirementInspectorRole
08/11/2026Shutoff dampers—energy_progress
07/13/2026Insulation placement and R values—energy_progress
07/13/2026Fenestration areas—energy_progress
07/13/2026Air barrier - visual inspection—energy_progress
07/13/2026Fenestration and door U-factor and product ratings—energy_progress
07/13/2026Fenestration air leakage—energy_progress
06/22/2026HVAC-R and service water heating system controls—energy_progress
06/22/2026Fire-Resistant Penetrations and Joints—special
06/22/2026Post-installed Anchors—special
06/22/2026Sprinkler Systems—special
06/22/2026Maintenance information—energy_progress
06/22/2026Fire-Resistant Penetrations and Joints—special
06/22/2026Post-installed Anchors—special
06/22/2026HVAC-R and service water heating equipment—energy_progress
06/22/2026Maintenance information—energy_progress
06/22/2026HVAC-R and service water piping design and insulation—energy_progress
06/22/2026Final—progress
06/22/2026HVAC-R and service water heating equipment—energy_progress
06/22/2026HVAC-R and service water piping design and insulation—energy_progress
06/22/2026HVAC-R and service water heating system controls—energy_progress
06/22/2026Chimneys and vents—special
06/22/2026Fire-Resistant Penetrations and Joints—special
06/22/2026Heating Systems—special
06/22/2026Post-installed Anchors—special
06/22/2026Mechanical Systems—special
Latest 25 of 29.
▾Documents — 23 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/17/2026B01380209-I1Request digital key ↗
08/16/2026B01414331-S1Request digital key ↗
08/16/2026B01426479-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/14/2026B01414331-I1Open ↗
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/17/2026B01380209-I1Open ↗
08/16/2026B01414331-S3Open ↗
08/16/2026B01414331-S2Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature1
08/25/2026B01380209-I1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist2
08/16/2026B01414331-S4Open ↗
08/14/2026B01414331-I1Open ↗
▸Other Documents7
▸DOB NOWProperty Ownership Certification2
08/17/2026B01380209-I1Open ↗
08/14/2026B01414331-I1Open ↗
▸DOB NOWSite Survey: Initial2
08/16/2026B01414331-S4Open ↗
08/14/2026B01414331-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/16/2026B01414331-S4Open ↗
08/14/2026B01414331-I1Open ↗
▸DOB NOWStructure Photographs1
08/17/2026B01380209-I1Open ↗