← Back
City residence, one family
414 10 STREET
BROOKLYN · BIN 3022612
💬 Discuss this project
1899Year Built
3Stories
A4Building Class
R6BZoning
—Gross Floor Area
1Units
City residence, one family · 1.08 FAR built · Flood zone X
Locations of Work
ArchitectureStructural
Permit Issued — active, not yet Signed-off
Roof2p · 1 filing · 14 docs
Floor 3Under Construction1 filing · 4 docs
Floor 2Under Construction1p · 1 filing · 4 docs
Floor 1Under Construction1p · 1 filing · 4 docs
CellarUnder Construction1p · 2 filings · 18 docs
1 job · most recent 07/31/2026
Sprinkler System
FiledStatusContractorScope
07/31/2026——Sprinkler System
1 job · most recent 06/09/2026
General Wiring
FiledStatusContractorScope
06/09/2026Permit IssuedPOWER SURGE ELECTRIC, INCGeneral Wiring
1 job · most recent 07/31/2026
Steel
FiledStatusContractorScope
07/31/2026——Steel
Building Lifecycle
All (48)Filed (3)Permit Issued (1)Objection (24)Special Inspection (20)
08/24/2026
Objection resolved — Resolved
08/24/2026
Objection resolved — Resolved
08/19/2026
Objection raised — Fire_Protection
08/19/2026
Objection raised — Structural
08/03/2026
Objection resolved — Resolved
08/03/2026
Objection resolved — Resolved
08/03/2026
Objection resolved — Resolved
07/31/2026
Filed — Alteration CO
VERTICAL ENLARGEMENT OF EXISTING 3-STORY,ONE(1) FAMILY DWELLING INTO A FOUR(4) STORY,AS PER PLANS SHOW.OBTAIN NEW CERTIFICATE OF OCCUPANCY.
B01412447-S1
07/31/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
07/30/2026
Special inspection requirement — Sprinkler Systems
07/29/2026
Objection resolved — Resolved
07/29/2026
Objection resolved — Resolved
07/29/2026
Objection resolved — Resolved
07/29/2026
Objection resolved — Resolved
07/29/2026
Objection resolved — Addressed
07/29/2026
Objection resolved — Resolved
07/29/2026
Objection resolved — Resolved
07/01/2026
Objection raised — Other
07/01/2026
Objection raised — Other
07/01/2026
Objection raised — Inspections
07/01/2026
Objection raised — Other
07/01/2026
Objection raised — Scope
07/01/2026
Objection raised — Energy
07/01/2026
Objection raised — Other
07/01/2026
Objection raised — Structural
07/01/2026
Objection raised — Scope
07/01/2026
Objection raised — Cost
06/16/2026
Filed — Alteration CO
VERTICAL ENLARGEMENT OF EXISTING 3-STORY,ONE(1) FAMILY DWELLING INTO A FOUR(4) STORY,AS PER PLANS SHOW.OBTAIN NEW CERTIFICATE OF OCCUPANCY.
B01412447-I1
06/16/2026
Special inspection requirement — Structural Cold-Formed Steel
06/16/2026
Special inspection requirement — Structural Steel - Details
06/16/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
06/16/2026
Special inspection requirement — Energy Code Compliance Inspections
06/16/2026
Special inspection requirement — Fire-Resistance Rated Construction
06/16/2026
Special inspection requirement — Air barrier — testing
06/16/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
06/16/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/16/2026
Special inspection requirement — Lighting in dwelling units
06/16/2026
Special inspection requirement — Maintenance information
06/16/2026
Special inspection requirement — Air barrier - visual inspection
06/16/2026
Special inspection requirement — Fenestration areas
06/16/2026
Special inspection requirement — Exterior lighting power
06/16/2026
Special inspection requirement — Fenestration air leakage
06/16/2026
Special inspection requirement — Lighting controls
06/16/2026
Special inspection requirement — Insulation placement and R values
06/04/2026
Special inspection requirement — Final
05/18/2026
Permit issued — General Construction
B01400179-I1-GC
05/13/2026
Filed — Alteration
INTERIOR DEMOLITION ON EXISTING ONE (1)-FAMILY, THREE (3) STORY FRAME RESIDENTIAL BUILDING WITH CELLAR.NO CHANGE OF BUILDING BULK, OCCUPANCY OR EGRESS
B01400179-I1
05/13/2026
Special inspection requirement — Energy Code Compliance Inspections
CALVIN TRAN
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
PSA BROOKLYN DEVELOPMENT208/29/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CQ&J CORPORATION207/31/2026
THOMAS C. TUNG, P.E.106/16/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MORELL BUILDERS INCGeneral Contractor107/08/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedMORELL BUILDERS INC05/18/2026
BISPLISSUEDSAL NAPOLI PLBG & HTG CORP12/03/2001
BIS—ISSUEDHOME CONSTRUCTION SERVICES INC07/19/2001
BIS—ISSUEDHOME CONSTRUCTION SERVICES INC01/31/2001
▾Special Inspection Requirements (DOB NOW) — 20
DateRequirementInspectorRole
07/31/2026Fire-Resistant Penetrations and Joints—special
07/30/2026Sprinkler Systems—special
06/16/2026Structural Cold-Formed Steel—special
06/16/2026Structural Steel - Details—special
06/16/2026Structural Stability – Alterations of existing buildings—special
06/16/2026Energy Code Compliance Inspections—progress
06/16/2026Fire-Resistance Rated Construction—progress
06/16/2026Air barrier — testing —energy_progress
06/16/2026Fenestration and door U-factor and product ratings—energy_progress
06/16/2026Fire-Resistant Penetrations and Joints—special
06/16/2026Lighting in dwelling units—energy_progress
06/16/2026Maintenance information—energy_progress
06/16/2026Air barrier - visual inspection—energy_progress
06/16/2026Fenestration areas—energy_progress
06/16/2026Exterior lighting power—energy_progress
06/16/2026Fenestration air leakage—energy_progress
06/16/2026Lighting controls—energy_progress
06/16/2026Insulation placement and R values—energy_progress
06/04/2026Final—progress
05/13/2026Energy Code Compliance InspectionsCALVIN TRANprogress
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/17/2026B01400179-I1Request digital key ↗
08/16/2026B01412447-S1Request digital key ↗
08/14/2026B01412447-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram1
08/14/2026B01412447-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/14/2026B01412447-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/14/2026B01412447-I1Open ↗
▸Seals & Professional Certifications4
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/17/2026B01400179-I1Open ↗
08/16/2026B01412447-I1Open ↗
08/16/2026B01412447-S1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
09/01/2026B01400179-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/14/2026B01412447-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/17/2026B01400179-I1Open ↗
08/16/2026B01412447-S1Open ↗
08/14/2026B01412447-I1Open ↗
▸Other Documents4
▸DOB NOWPlot Diagram1
08/14/2026B01412447-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/14/2026B01412447-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/14/2026B01412447-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/14/2026B01412447-I1Open ↗