← Back
Primarily 2 family with 1 store or office
670 FRANKLIN AVENUE
BROOKLYN · BIN 3028673
💬 Discuss this project
1930Year Built
3Stories
S2Building Class
R7AZoning
3,500 sfGross Floor Area
3Units
Rent Stabilized13 Open Violations 12 unresolved · 1 paperwork only ▸FDNY Report ↗
Primarily 2 family with 1 store or office · 1,575 sf lot · 2.22 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
670 FRANKLIN AVE403/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BRIAN ILL DEVELOPMENT LLC610/07/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MILETO ARCH ASSOCAITE DPC1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HIGH QUALITY CONSTRUCTIONGeneral Contractor507/08/2026
KJK ELECTRIC INCElectrical103/22/2026
WATSON'S PLBG, HTG, & BDGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BRIAN ILL DEVELOPMENT LLC1402510/07/2024
Building Lifecycle
All (67)Filed (6)Permit Issued (4)Signed Off (3)Violation (20)Inspection (4)Special Inspection (30)
05/28/2025
Violation issued (ECB, closed)
Construction
10/08/2024
Signed off — Alteration
install temp construction fence
B00756318-I1
10/08/2024
Signed off — Alteration
RENOVATION OF EXISTING COMMERCIAL SPACE. INSTALL NEW PARTITIONS, FLOOR/WALL FINISHES AND PAINT EXISTING CEILING TITLES. MECHANICAL WORK FOR INSTALLING EHXHASUT HOOD IN EXISTING COMMERCAIL KITCHEN / RESTAURANT ON 1ST FLOOR.
B00756312-I1
10/07/2024
Signed off — Alteration
install new plumbingfixtures and cooking equipment in commercial kitchen on 1st floor. install new fire suppression system in kitchen
B00756321-I1
10/07/2024
Filed — Alteration
RENOVATION OF EXISTING COMMERCIAL SPACE. INSTALL NEW PARTITIONS, FLOOR/WALL FINISHES AND PAINT EXISTING CEILING TITLES. MECHANICAL WORK FOR INSTALLING EHXHASUT HOOD IN EXISTING COMMERCAIL KITCHEN / RESTAURANT ON 1ST FLOOR.
B00756312-P2
10/04/2024
Special inspection requirement — HVAC-R and service water heating equipment
BRIAN ILL
10/04/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
BRIAN ILL
10/04/2024
Special inspection requirement — Fenestration air leakage
BRIAN ILL
10/04/2024
Special inspection requirement — Lighting controls
BRIAN ILL
10/04/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
BRIAN ILL
10/04/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
BRIAN ILL
10/04/2024
Special inspection requirement — Mechanical Systems
BRIAN ILL
10/04/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
BRIAN ILL
10/04/2024
Special inspection requirement — Energy Code Compliance Inspections
BRIAN ILL
10/04/2024
Special inspection requirement — Final
BRIAN ILL
10/04/2024
Special inspection requirement — Fire-Resistance Rated Construction
BRIAN ILL
10/04/2024
Special inspection requirement — Interior lighting power
BRIAN ILL
10/04/2024
Special inspection requirement — HVAC-R and service water heating system controls
BRIAN ILL
10/04/2024
Special inspection requirement — Fenestration areas
BRIAN ILL
01/19/2023
Filed — Alteration
RENOVATION OF EXISTING COMMERCIAL SPACE. INSTALL NEW PARTITIONS, FLOOR/WALL FINISHES AND PAINT EXISTING CEILING TITLES. MECHANICAL WORK FOR INSTALLING EHXHASUT HOOD IN EXISTING COMMERCAIL KITCHEN / RESTAURANT ON 1ST FLOOR.
B00756312-P1
01/19/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
BRIAN ILL
01/19/2023
Special inspection requirement — Energy Code Compliance Inspections
BRIAN ILL
01/19/2023
Special inspection requirement — HVAC-R and service water heating equipment
BRIAN ILL
01/19/2023
Special inspection requirement — HVAC-R and service water heating system controls
BRIAN ILL
01/19/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
BRIAN ILL
01/19/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
BRIAN ILL
01/19/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
BRIAN ILL
01/19/2023
Special inspection requirement — Mechanical Systems
BRIAN ILL
01/19/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
BRIAN ILL
01/19/2023
Special inspection requirement — Energy Code Compliance Inspections
BRIAN ILL
01/19/2023
Special inspection requirement — Final
BRIAN ILL
01/19/2023
Special inspection requirement — Fire-Resistance Rated Construction
BRIAN ILL
01/19/2023
Special inspection requirement — Fenestration areas
BRIAN ILL
01/19/2023
Special inspection requirement — Fenestration air leakage
BRIAN ILL
01/19/2023
Special inspection requirement — HVAC-R and service water heating system controls
BRIAN ILL
01/19/2023
Special inspection requirement — Interior lighting power
BRIAN ILL
01/13/2023
Filed — Alteration
install new plumbingfixtures and cooking equipment in commercial kitchen on 1st floor. install new fire suppression system in kitchen
B00756321-P1
01/09/2023
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
09/20/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
09/20/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/20/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
08/31/2022
Permit issued — Plumbing
B00756321-I1-PL
07/21/2022
Permit issued — General Construction
B00756312-I1-MS
07/21/2022
Permit issued — General Construction
B00756312-I1-GC
07/21/2022
Permit issued — Construction Fence
B00756318-I1-FN
07/06/2022
Filed — Alteration
install temp construction fence
B00756318-I1
07/06/2022
Filed — Alteration
RENOVATION OF EXISTING COMMERCIAL SPACE. INSTALL NEW PARTITIONS, FLOOR/WALL FINISHES AND PAINT EXISTING CEILING TITLES. MECHANICAL WORK FOR INSTALLING EHXHASUT HOOD IN EXISTING COMMERCAIL KITCHEN / RESTAURANT ON 1ST FLOOR.
B00756312-I1
07/06/2022
Filed — Alteration
install new plumbingfixtures and cooking equipment in commercial kitchen on 1st floor. install new fire suppression system in kitchen
B00756321-I1
07/23/2011
Violation issued (ECB, open)
Construction
04/01/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/09/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/12/2009
Violation issued (ECB, closed)
Construction
05/08/2009
Violation issued (DOB, closed)
VW*-VIOLATION - WORK W/O PERMIT DISMISSED
09/13/2007
Violation issued (ECB, closed)
Construction
07/21/2004
Violation issued (ECB, closed)
Construction
04/28/2004
Violation issued (HPD, open)
B
04/28/2004
Violation issued (HPD, open)
B
04/28/2004
Violation issued (HPD, open)
A
04/28/2004
Violation issued (HPD, open)
B
04/28/2004
Violation issued (HPD, open)
B
Latest 60 of 67 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offWATSON'S PLBG, HTG, & BDG08/31/2022
DOB NOWGeneral ConstructionSigned-offHIGH QUALITY CONSTRUCTION07/21/2022
DOB NOWGeneral ConstructionSigned-offHIGH QUALITY CONSTRUCTION07/21/2022
DOB NOWConstruction FenceSigned-offHIGH QUALITY CONSTRUCTION07/21/2022
BISOTISSUEDMANHATTAN ASS. CONS. CORP03/14/2011
BISOTISSUEDMANHATTAN ASS. CONS. CORP11/18/2010
BISMHISSUEDMANHATTAN ASS. CONS. CORP11/03/2010
BISPLISSUEDALJER PLBG & HTG CORP03/18/2010
BISOTISSUEDCROWN CONSTRUCTION BUILD03/15/2010
BISOTISSUEDLEROY JOHNSON07/01/2009
1 project · most recent 05/08/2023
General Wiring
FiledStatusContractorScope
05/08/2023CompleteKJK ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
01/09/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
09/20/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
09/20/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/20/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 38
DateRequirementInspectorRole
10/04/2024HVAC-R and service water heating equipmentBRIAN ILLenergy_progress
10/04/2024Fenestration and door U-factor and product ratingsBRIAN ILLenergy_progress
10/04/2024Fenestration air leakageBRIAN ILLenergy_progress
10/04/2024Lighting controlsBRIAN ILLenergy_progress
10/04/2024HVAC-R and service water piping design and insulationBRIAN ILLenergy_progress
10/04/2024Fire-Resistant Penetrations and JointsBRIAN ILLspecial
10/04/2024Mechanical SystemsBRIAN ILLspecial
10/04/2024Structural Stability – Alterations of existing buildingsBRIAN ILLspecial
10/04/2024Energy Code Compliance InspectionsBRIAN ILLprogress
10/04/2024FinalBRIAN ILLprogress
10/04/2024Fire-Resistance Rated ConstructionBRIAN ILLprogress
10/04/2024Interior lighting powerBRIAN ILLenergy_progress
10/04/2024HVAC-R and service water heating system controlsBRIAN ILLenergy_progress
10/04/2024Fenestration areasBRIAN ILLenergy_progress
01/19/2023HVAC-R and service water piping design and insulationBRIAN ILLenergy_progress
01/19/2023Energy Code Compliance InspectionsBRIAN ILLprogress
01/19/2023HVAC-R and service water heating equipmentBRIAN ILLenergy_progress
01/19/2023HVAC-R and service water heating system controlsBRIAN ILLenergy_progress
01/19/2023HVAC-R and service water piping design and insulationBRIAN ILLenergy_progress
01/19/2023Fire-Resistant Penetrations and JointsBRIAN ILLspecial
01/19/2023Fire-Resistant Penetrations and JointsBRIAN ILLspecial
01/19/2023Mechanical SystemsBRIAN ILLspecial
01/19/2023Structural Stability – Alterations of existing buildingsBRIAN ILLspecial
01/19/2023Energy Code Compliance InspectionsBRIAN ILLprogress
01/19/2023FinalBRIAN ILLprogress
Latest 25 of 38.
▾Documents — 59 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/29/2026B00756312-P2Request digital key ↗
08/29/2026B00756312-P1Request digital key ↗
08/29/2026B00756312-I1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits8
▸BISWORK PERMIT APPLICATION6
03/15/2011320014462Open ↗
11/22/2010320014462Open ↗
11/04/2010320217270Open ↗
Showing 3 of 6 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION2
09/23/2010320217270Open ↗
05/12/2009320014462Open ↗
▸Seals & Professional Certifications25
▸DOB NOWProgress Inspector Seal & Signature12
08/29/2026B00756312-P2Open ↗
08/29/2026B00756312-P2Open ↗
08/29/2026B00756312-P1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/29/2026B00756312-P2Open ↗
08/29/2026B00756312-P1Open ↗
08/29/2026B00756312-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/29/2026B00756312-P2Open ↗
08/29/2026B00756312-P1Open ↗
08/26/2026B00756321-P1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
09/23/2010320217270Open ↗
05/12/2009320014462Open ↗
05/12/2009320014462Open ↗
▸Trade Schedules & Equipment3
▸BISSCHEDULE B - PLUMBING2
09/23/2010320217270Open ↗
05/12/2009320014462Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT1
09/23/2010320217270Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST2
09/23/2010320217270Open ↗
05/12/2009320014462Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/29/2026B00756312-P2Open ↗
08/29/2026B00756312-P1Open ↗
08/29/2026B00756312-I1Open ↗
Showing 3 of 5 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
09/23/2010320217270Open ↗
05/12/2009320014462Open ↗
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis2
08/29/2026B00756312-I1Open ↗
08/13/2026B00756321-I1Open ↗
▸Approvals, Objections & Sign-offs2
▸BISADMINISTRATIVE OBJECTIONS2
09/23/2010320217270Open ↗
05/12/2009320014462Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
09/23/2010320217270Open ↗
05/12/2009320014462Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET2
09/23/2010320217270Open ↗
05/12/2009320014462Open ↗