← Back
Two family brick
929 ST MARKS AVENUE
BROOKLYN · BIN 3030853
💬 Discuss this project
1896Year Built
3Stories
B1Building Class
R6Zoning
4,380 sfGross Floor Area
2Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Two family brick · Owner of record: KINGSTON CAPITAL LLC · 2,712 sf lot · 1.62 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire ProtectionGeneral
Roof32p · 2 filings · 20 docs
Floor 327p · 2 filings · 20 docs
Floor 226p · 1 filing · 17 docs
Floor 126p · 1 filing · 17 docs
Cellar30p · 3 filings · 20 docs
Basement26p · 1 filing · 17 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
CANYON HOLDING2107/08/2026
KINGSTON CAPITAL LLC203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/13/2021$1.2M—— → —$285/sf building
01/03/2019$80K—Private party → LOCAL 102 LLC$18/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PIROOZ ENGINEERING, P.C.804/08/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KD DESIGNS503/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
A & S CONTRACTORS OF NY IGeneral Contractor807/08/2026
DYNAMIC PLBNG & SPRKR CORFire Protection207/08/2026
TRINCITY ELECTRIC, INCElectrical103/22/2026
HORBRIDGE PLUMBING & HEATINGPlumbing107/08/2026
M & M PIPING AND HEATINGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PIROOZ ENGINEERING P.C7177504/08/2026
BUTTERFIELD & O'CONNOR4189210/28/2025
Building Lifecycle
All (115)Filed (8)Permit Issued (9)Signed Off (2)Violation (21)Inspection (13)Objection (52)Special Inspection (10)
07/21/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/20/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/13/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/02/2026
Special inspection requirement — Preliminary
BRIAN T. O'CONNOR
07/02/2026
Special inspection requirement — Final
NAVEEN KUMAR
07/02/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
BRIAN T. O'CONNOR
07/02/2026
Special inspection requirement — Heating Systems
BRIAN T. O'CONNOR
07/02/2026
Special inspection requirement — Mechanical Systems
BRIAN T. O'CONNOR
07/02/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
BRIAN T. O'CONNOR
07/02/2026
Special inspection requirement — Fire-Resistance Rated Construction
BRIAN T. O'CONNOR
06/22/2026
Objection resolved — Addressed
05/22/2026
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
05/12/2026
Signed off — Alteration
Application filed for Plumbing and Sprinkler work type in conjunction with ALTERATION CO application number B00767200
B00767206-I1
05/11/2026
Signed off — Alteration
B00767201-I1
05/06/2026
Violation issued (HPD, closed)
A
04/28/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/08/2026
Filed — Alteration
Application filed for Plumbing and Sprinkler work type in conjunction with ALTERATION CO application number B00767200
B00767206-P2
04/07/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
PIROOZ SOLTANIZADEH
03/02/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
02/26/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
02/09/2026
Permit issued — Sprinklers
B00870889-I1-EW-SP
12/19/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
12/08/2025
Special inspection requirement — Sprinkler Systems
PIROOZ SOLTANIZADEH
11/20/2025
Objection resolved — Addressed
11/17/2025
Objection raised — Admin
11/10/2025
Objection raised — Other
10/29/2025
Filed — Alteration
APPLICATION FILED FOR MODIFICATION OF THE EXISTING SPRINKLER SYSTEM IN CONJUNCTION WITH ALTERATION CO APPLICATION NUMBER B00767200
B00870889-P1
10/28/2025
Filed — Alteration
Application filed for Plumbing and Sprinkler work type in conjunction with ALTERATION CO application number B00767200
B00767206-P1
10/28/2025
Filed — Alteration CO
EXISTING 3 STORY WITH BASEMENT AND CELLAR (MULTI-FAMILY), PROPOSED 3 STORY WITH BASEMENT AND CELLAR (TWO FAMILY), NO HORIZONTAL AND VERTICAL EXTENSION, NO CHANGE IN BULK
B00767200-P1
10/23/2025
Special inspection requirement — Sprinkler Systems
PIROOZ SOLTANIZADEH
08/12/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/04/2025
Permit issued — General Construction
B00767200-I1-GC-CX
07/29/2025
Permit issued — Plumbing
B00767206-I1-PL
06/11/2025
Violation issued (HPD, closed)
A
04/11/2024
Violation issued (HPD, closed)
A
12/22/2023
Permit issued — Mechanical Systems
B00767200-I1-GC-CX
12/22/2023
Permit issued — Construction Fence
B00767201-I1-FN
11/20/2023
Violation issued (HPD, closed)
I
07/18/2023
Permit issued — Sprinklers
B00870889-I1-EW-SP
06/16/2023
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
06/16/2023
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
06/16/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/16/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/12/2023
Permit issued — Plumbing
B00767206-I1-PL
05/25/2023
Objection resolved — Addressed
05/25/2023
Objection resolved — Addressed
05/25/2023
Objection resolved — Addressed
05/18/2023
Objection raised — Other
05/18/2023
Objection raised — Inspections
05/18/2023
Objection raised — Other
05/05/2023
Filed — Alteration
Application filed for Plumbing and Sprinkler work type in conjunction with ALTERATION CO application number B00767200
B00767206-I1
05/05/2023
Filed — Alteration
APPLICATION FILED FOR MODIFICATION OF THE EXISTING SPRINKLER SYSTEM IN CONJUNCTION WITH ALTERATION CO APPLICATION NUMBER B00767200
B00870889-I1
03/27/2023
Violation issued (HPD, closed)
A
03/02/2023
Permit issued — Construction Fence
B00767201-I1-FN
02/27/2023
Permit issued — General Construction
B00767200-I1-GC-CX
02/22/2023
Filed — Alteration
B00767201-I1
02/21/2023
Objection resolved — Addressed
01/20/2023
Objection resolved — Addressed
01/20/2023
Objection resolved — Addressed
01/20/2023
Objection resolved — Addressed
Latest 60 of 115 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offCITYWIDE PLBG, HTG &SPRKL02/09/2026
DOB NOWGeneral ConstructionPermit IssuedA S CONTRACTORS OF NY I08/04/2025
DOB NOWPlumbingSigned-offM & M PIPING AND HEATING07/29/2025
DOB NOWMechanical SystemsPermit IssuedA S CONTRACTORS OF NY I12/22/2023
DOB NOWConstruction FenceSigned-offA S CONTRACTORS OF NY I12/22/2023
DOB NOWSprinklersSigned-offCITYWIDE PLBG, HTG &SPRKL07/18/2023
DOB NOWPlumbingSigned-offHORBRIDGE PLUMBING & HEAT06/12/2023
DOB NOWConstruction FenceSigned-offA S CONTRACTORS OF NY I03/02/2023
DOB NOWGeneral ConstructionPermit IssuedA S CONTRACTORS OF NY I02/27/2023
1 project · most recent 10/28/2025
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
10/28/2025Permit IssuedA & S CONTRACTORS OF NY IHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MSZ-GL24NA 228,000 BTU · Split System ×24
Ventilation
Panasonic PANASONIC 50 CFM · Exhaust Fan ×158
1 project · most recent 10/29/2025
FiledStatusContractorScope
10/29/2025Signed-offDYNAMIC PLBNG & SPRKR COR—
1 project · most recent 06/10/2026
General Wiring
FiledStatusContractorScope
06/10/2026CompleteTRINCITY ELECTRIC, INCGeneral Wiring
▾Field Inspections (DOB CAP) — 13
DateTypeResultReport
07/21/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/20/2026Pass-Final CND-Occupancy InspectionPassView ↗
07/13/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/22/2026Pass-Final PL - UndergroundPassView ↗
04/28/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/02/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
02/26/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
12/19/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/12/2025Pass-Final CND-Occupancy InspectionPassView ↗
06/16/2023Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
06/16/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
06/16/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/16/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
07/02/2026PreliminaryBRIAN T. O'CONNORprogress
07/02/2026FinalNAVEEN KUMARprogress
07/02/2026Fire-Resistant Penetrations and JointsBRIAN T. O'CONNORspecial
07/02/2026Heating SystemsBRIAN T. O'CONNORspecial
07/02/2026Mechanical SystemsBRIAN T. O'CONNORspecial
07/02/2026Structural Stability – Alterations of existing buildingsBRIAN T. O'CONNORspecial
07/02/2026Fire-Resistance Rated ConstructionBRIAN T. O'CONNORprogress
04/07/2026Fire-Resistant Penetrations and JointsPIROOZ SOLTANIZADEHspecial
12/08/2025Sprinkler SystemsPIROOZ SOLTANIZADEHspecial
10/23/2025Sprinkler SystemsPIROOZ SOLTANIZADEHspecial
▾Documents — 43 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/27/2026B00767201-I1Request digital key ↗
08/20/2026B00870889-I1Request digital key ↗
08/20/2026B00870889-P1Request digital key ↗
Showing 3 of 8 on file for this type
▸Applications & Permits5
▸DOB NOWLPC Approval/Permit5
08/17/2026B00767206-I1Open ↗
08/17/2026B00767206-P2Open ↗
08/13/2026B00767206-P1Open ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications14
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/27/2026B00767201-I1Open ↗
08/20/2026B00870889-P1Open ↗
08/20/2026B00870889-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/01/2026B00767206-P2Open ↗
09/01/2026B00870889-P1Open ↗
09/01/2026B00767200-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026B00767200-I1Open ↗
09/01/2026B00767200-I1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist2
08/13/2026B00767200-I1Open ↗
08/13/2026B00767200-P1Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/20/2026B00870889-P1Open ↗
08/20/2026B00870889-I1Open ↗
08/17/2026B00767206-P2Open ↗
Showing 3 of 7 on file for this type
▸Other Documents7
▸DOB NOWProof of Historic Building5
08/17/2026B00767206-P2Open ↗
08/17/2026B00767206-I1Open ↗
08/13/2026B00767200-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProperty Ownership Certification2
08/13/2026B00767200-I1Open ↗
08/13/2026B00767200-P1Open ↗