| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 07/26/2024 | Signed-off | PALONE BROTHERS AIR | Heating and Air Conditioning Systems | Heat / Cool Mitsubishi Electric TUMYP0361AK43NA 3 tons · Vrf Outdoor ×2 TUMYP0481AK43NA 4 tons · Condensing Unit ×2 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/26/2024 | Signed-off | ASPECT PLBNG&HTNG CO LLC | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/22/2023 | Complete | SUNBIRD ELECTRICAL CONTR | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/26/2024 | Signed-off | PALONE BROTHERS AIR | Steel, Concrete, Masonry, Wood |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 08/20/2015 | $1.8M | — | VERDELL HENDERSON ESTATE → Private party | $622/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| E.G. ARCHITECTURE PLLC | 5 | 07/26/2024 |
| EP ENGINEERING LLC | 2 | 12/19/2023 |
| M C STRUCTURAL ENGINEERING | 2 | 09/14/2022 |
| Representative | Filings | Most Recent |
|---|---|---|
| JOSEPH FELLNER | 9 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| DESIGN TECH CONSTRUCT COR | General Contractor | 3 | 07/08/2026 |
| SUNBIRD ELECTRICAL CONTR | Electrical | 1 | 03/22/2026 |
| PALONE BROTHERS AIR | General Contractor | 1 | 07/08/2026 |
| ASPECT PLBNG&HTNG CO LLC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| JAJ ENGINEERING PLLC | 930 | 9 | 07/26/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Mechanical Systems | Signed-off | PALONE BROTHERS AIR | 01/04/2024 |
| DOB NOW | Foundation | Signed-off | DESIGN TECH CONSTRUCT COR | 10/26/2022 |
| DOB NOW | Plumbing | Signed-off | ASPECT PLBNG&HTNG CO LLC | 09/07/2022 |
| DOB NOW | Structural | Signed-off | DESIGN TECH CONSTRUCT COR | 08/17/2022 |
| DOB NOW | General Construction | Permit Issued | DESIGN TECH CONSTRUCT COR | 08/04/2022 |
| Date | Type | Result | Report |
|---|---|---|---|
| 04/11/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 04/25/2023 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 04/24/2023 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 02/15/2023 | Pass-Final PL - Up to 3 Requested Floors | Pass | View ↗ |
| 11/18/2022 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 08/30/2022 | Pass-Final SD - Fire Pump | Pass | View ↗ |
| 08/23/2022 | Certified StandPipe-SD-Fixtures-Finish-SD | Certified | View ↗ |
| 08/19/2022 | Certified StandPipe-SD-Piping-Hydrostatic Test | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 08/06/2024 | Fire-Resistant Penetrations and Joints | Joseph Jabour | special |
| 08/06/2024 | Air barrier - visual inspection | Lisa Ekle | energy_progress |
| 08/06/2024 | Insulation placement and R values | Lisa Ekle | energy_progress |
| 08/06/2024 | Fenestration and door U-factor and product ratings | Lisa Ekle | energy_progress |
| 08/06/2024 | Fenestration areas | Lisa Ekle | energy_progress |
| 08/06/2024 | Fenestration air leakage | Lisa Ekle | energy_progress |
| 08/06/2024 | Lighting in dwelling units | Lisa Ekle | energy_progress |
| 08/06/2024 | Energy Code Compliance Inspections | Lisa Ekle | progress |
| 08/06/2024 | Fire-Resistance Rated Construction | Lisa Ekle | progress |
| 08/06/2024 | Structural Stability – Alterations of existing buildings | Joseph Jabour | special |
| 06/18/2024 | Fenestration air leakage | Lisa Ekle | energy_progress |
| 06/18/2024 | Lighting in dwelling units | Lisa Ekle | energy_progress |
| 06/18/2024 | Fenestration areas | Lisa Ekle | energy_progress |
| 06/18/2024 | Fire-Resistance Rated Construction | Lisa Ekle | progress |
| 06/18/2024 | Energy Code Compliance Inspections | Lisa Ekle | progress |
| 06/18/2024 | Structural Stability – Alterations of existing buildings | Joseph Jabour | special |
| 06/18/2024 | Fire-Resistant Penetrations and Joints | Joseph Jabour | special |
| 06/18/2024 | Fenestration and door U-factor and product ratings | Lisa Ekle | energy_progress |
| 06/18/2024 | Insulation placement and R values | Lisa Ekle | energy_progress |
| 06/18/2024 | Air barrier - visual inspection | Lisa Ekle | energy_progress |
| 12/22/2023 | HVAC-R and service water heating equipment | Joseph Jabour | energy_progress |
| 12/22/2023 | Mechanical Systems | Joseph Jabour | special |
| 12/22/2023 | Energy Code Compliance Inspections | Joseph Jabour | progress |
| 12/22/2023 | Final | Joseph Jabour | progress |
| 12/22/2023 | Shutoff dampers | Joseph Jabour | energy_progress |