Primarily 2 family with 1 store or office
227 UTICA AVENUE
BROOKLYN · BIN 3036852
💬 Discuss this project
1915Year Built
3Stories
S2Building Class
R6Zoning
3,135 sfGross Floor Area
3Units
Rent Stabilized23 Open Violations ▸FDNY Report ↗
Primarily 2 family with 1 store or office · Owner of record: SADIO HOUSES LLC · 1,560 sf lot · 2.01 FAR built · Flood zone X
Locations of Work
Mechanical
Floor 11p · 1 filing · 10 docs
Cellar1p · 1 filing · 10 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/08/2025$1.4M—— → —$439/sf building
05/13/2024$20K—— → —$6/sf building
07/02/2019$980K—CALENDAR TRAVEL AGENCY, LTD. → 227 UTICA AVE LLC$313/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SU ARCHITECT, P.C.204/01/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KALE CONSTRUCTION INCGeneral Contractor207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SU ARCHITECT PC6857204/01/2026
Building Lifecycle
All (45)Filed (2)Permit Issued (2)Violation (25)Inspection (3)Special Inspection (13)
08/10/2026
Violation issued (HPD, open)
I
08/05/2026
Violation issued (HPD, open)
B
08/05/2026
Violation issued (HPD, open)
C
08/05/2026
Violation issued (HPD, open)
C
08/05/2026
Violation issued (HPD, open)
C
08/05/2026
Violation issued (HPD, open)
C
08/05/2026
Violation issued (HPD, open)
A
08/05/2026
Violation issued (HPD, open)
B
04/01/2026
Filed — Alteration
TO PROPOSE NEW PLUMBING FIXTURES FOR COMMERCIAL RESTAURANT ON CELLAR AND 001 FLOOR WITH PLUMBING WORK TYPE AS PER PLAN FILED HEREWITH; NO CHANGE OF USE, EGRESS OR CERTIFICATE OF OCCUPANCY.
B01298475-I1
04/01/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
QIANG SU
04/01/2026
Special inspection requirement — Energy Code Compliance Inspections
QIANG SU
04/01/2026
Special inspection requirement — HVAC-R and service water heating equipment
QIANG SU
04/01/2026
Special inspection requirement — HVAC-R and service water heating system controls
QIANG SU
04/01/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
QIANG SU
12/03/2025
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
10/27/2025
Special inspection requirement — Tenant Protection Plan Compliance
QIANG SU
09/24/2025
Permit issued — Mechanical Systems
B01261951-I1-MS
09/24/2025
Permit issued — Mechanical Systems
B01261951-I1-GC
08/27/2025
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
08/18/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
08/08/2025
Filed — Alteration
TO INSTALL PARTITION WALLS AND COMMERCIAL EXHAUST HOOD FOR COMMERCIAL RESTAURANT WITH GENERAL CONSTRUCTION AND MECHANICAL WORK TYPE AS PER PLAN FILED HEREWITH. NO CHANGE OF USE, EGRESS OR CERTIFICATE OF OCCUPANCY.
B01261951-I1
08/08/2025
Special inspection requirement — Fire-Resistance Rated Construction
QIANG SU
07/28/2025
Special inspection requirement — Ventilation and air distribution system
QIANG SU
07/28/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
QIANG SU
07/28/2025
Special inspection requirement — Tenant Protection Plan Compliance
QIANG SU
07/28/2025
Special inspection requirement — Energy Code Compliance Inspections
QIANG SU
07/25/2025
Special inspection requirement — Mechanical Systems
QIANG SU
07/25/2025
Special inspection requirement — Final
Giap Flores
01/06/2025
Violation issued (HPD, open)
C
01/06/2025
Violation issued (HPD, open)
C
01/02/2025
Violation issued (HPD, closed)
I
12/31/2024
Violation issued (HPD, open)
C
09/27/2023
Violation issued (HPD, closed)
I
09/26/2023
Violation issued (HPD, open)
B
09/26/2023
Violation issued (HPD, open)
B
09/26/2023
Violation issued (HPD, open)
C
09/26/2023
Violation issued (HPD, open)
A
09/26/2023
Violation issued (HPD, open)
B
10/20/2006
Violation issued (HPD, open)
A
10/20/2006
Violation issued (HPD, open)
B
10/20/2006
Violation issued (HPD, open)
B
10/20/2006
Violation issued (HPD, open)
B
10/20/2006
Violation issued (HPD, open)
B
10/20/2006
Violation issued (HPD, open)
C
10/20/2006
Violation issued (HPD, open)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedKALE CONSTRUCTION INC09/24/2025
DOB NOWMechanical SystemsPermit IssuedKALE CONSTRUCTION INC09/24/2025
1 project · most recent 08/08/2025
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/08/2025Permit IssuedKALE CONSTRUCTION INCVentilation Systems
Ventilation
Captiveaire DU240HFA 5,000 CFM · Kitchen Exhaust ×1
1 project · most recent 04/01/2026
Gas Water/Sanitary
FiledStatusContractorScope
04/01/2026——Gas, Water/Sanitary
1 project · most recent 04/22/2025
FiledStatusContractorScope
04/22/2025CompleteWORD OF LIGHT ELECT LLC4 meters
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
12/03/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
08/27/2025Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
08/18/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
04/01/2026HVAC-R and service water piping design and insulationQIANG SUenergy_progress
04/01/2026Energy Code Compliance InspectionsQIANG SUprogress
04/01/2026HVAC-R and service water heating equipmentQIANG SUenergy_progress
04/01/2026HVAC-R and service water heating system controlsQIANG SUenergy_progress
04/01/2026Fire-Resistant Penetrations and JointsQIANG SUspecial
10/27/2025Tenant Protection Plan ComplianceQIANG SUspecial
08/08/2025Fire-Resistance Rated ConstructionQIANG SUprogress
07/28/2025Ventilation and air distribution systemQIANG SUenergy_progress
07/28/2025Fire-Resistant Penetrations and JointsQIANG SUspecial
07/28/2025Tenant Protection Plan ComplianceQIANG SUspecial
07/28/2025Energy Code Compliance InspectionsQIANG SUprogress
07/25/2025Mechanical SystemsQIANG SUspecial
07/25/2025FinalGiap Floresprogress
▾Documents — 19 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/21/2026B01261951-I1Request digital key ↗
08/17/2026B01298475-I1Request digital key ↗
▸Seals & Professional Certifications15
▸DOB NOWProgress Inspector Seal & Signature8
09/23/2026B01261951-I1Open ↗
09/23/2026B01261951-I1Open ↗
09/23/2026B01261951-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/23/2026B01261951-I1Open ↗
09/23/2026B01261951-I1Open ↗
09/23/2026B01261951-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/21/2026B01261951-I1Open ↗
08/17/2026B01298475-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/21/2026B01261951-I1Open ↗
08/17/2026B01298475-I1Open ↗