← Back
Four families
1961 UNION STREET
BROOKLYN · BIN 3037634
💬 Discuss this project
1923Year Built
2Stories
C3Building Class
R6Zoning
3,200 sfGross Floor Area
4Units
Rent Stabilized30 Open Violations 28 unresolved · 2 paperwork only ▸FDNY Report ↗
Four families · 2,475 sf lot · 1.29 FAR built · Flood zone X
Locations of Work
Plumbing
Permit Issued — active, not yet Signed-off
CellarUnder Construction2p · 1 filing · 8 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PWR ENGINEERING DESIGN DPC309/11/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KP CONSULTING ENGINEER403/21/2026
KMP DESIGN ENGINEERING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PP COUSIN INCPlumbing207/08/2026
MORRIS HELLERElectrical103/21/2026
THREE GLOVES CONSTRUCTIONGeneral Contractor107/08/2026
M & M PIPING AND HEATINGPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
KCE CONSULTING ENGINEERIN3712309/11/2025
Building Lifecycle
All (91)Filed (3)Permit Issued (4)Violation (60)Inspection (8)Objection (12)Special Inspection (4)
05/18/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/06/2026
Violation issued (HPD, closed)
A
04/21/2026
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
04/13/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/10/2026
Permit issued — Plumbing
B01082862-S1-PL
03/10/2026
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
11/20/2025
Violation issued (HPD, closed)
I
10/10/2025
Permit issued — Plumbing
B01082862-S1-PL
09/11/2025
Filed — Alteration
PLUMBING WORK-TYPE ONLY IN CONJUNCTION WITH FILING OF GC JOB# B01058543-I1 TO REMOVE 3-PIECE BATHROOM AND REMOVE EXISTING KITCHEN AT CELLAR; REMOVING ILLEGAL CONDITION AND REMEDIATE VIOLATION #347-969-57Y, #347-969-56M.
B01082862-S1
09/02/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kemba Walcott
08/13/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
07/31/2025
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
03/21/2025
Permit issued — Plumbing
B01082862-I1-PL
11/20/2024
Permit issued — General Construction
B01058543-I1-GC
11/15/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
10/24/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
10/21/2024
Violation issued (HPD, closed)
B
10/21/2024
Violation issued (HPD, closed)
B
10/11/2024
Filed — Alteration
PLUMBING WORK-TYPE ONLY IN CONJUNCTION WITH FILING OF GC JOB# B01058543-I1 TO REMOVE 3-PIECE BATHROOM AND REMOVE EXISTING KITCHEN AT CELLAR; REMOVING ILLEGAL CONDITION AND REMEDIATE VIOLATION #347-969-57Y, #347-969-56M.
B01082862-I1
10/09/2024
Violation issued (HPD, closed)
A
10/09/2024
Violation issued (HPD, open)
B
10/09/2024
Violation issued (HPD, open)
C
10/09/2024
Violation issued (HPD, closed)
A
10/09/2024
Violation issued (HPD, closed)
A
10/09/2024
Violation issued (HPD, closed)
B
10/09/2024
Violation issued (HPD, closed)
B
10/09/2024
Violation issued (HPD, closed)
C
10/09/2024
Violation issued (HPD, open)
B
10/09/2024
Violation issued (HPD, open)
C
10/09/2024
Violation issued (HPD, closed)
A
10/09/2024
Violation issued (HPD, closed)
B
10/09/2024
Violation issued (HPD, closed)
B
10/09/2024
Violation issued (HPD, closed)
B
10/09/2024
Violation issued (HPD, closed)
A
10/09/2024
Violation issued (HPD, closed)
A
10/09/2024
Violation issued (HPD, closed)
B
10/09/2024
Violation issued (HPD, closed)
B
10/09/2024
Violation issued (HPD, closed)
B
10/09/2024
Violation issued (HPD, closed)
C
10/09/2024
Violation issued (HPD, closed)
B
10/09/2024
Violation issued (HPD, closed)
C
09/24/2024
Objection resolved — Addressed
08/28/2024
Objection resolved — Addressed
07/23/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kemba Walcott
07/18/2024
Objection resolved — Addressed
07/18/2024
Objection resolved — Addressed
07/18/2024
Objection resolved — Addressed
07/18/2024
Objection resolved — Addressed
07/08/2024
Objection raised — Scope
07/08/2024
Objection raised — Scope
07/08/2024
Objection raised — Admin
07/08/2024
Objection raised — Other
07/08/2024
Objection raised — Other
07/08/2024
Objection raised — Inspections
06/27/2024
Filed — Alteration
B01058543-I1
06/12/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kemba Walcott
06/12/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Kemba Walcott
04/12/2024
Violation issued (HPD, closed)
A
03/29/2024
Violation issued (HPD, open)
C
03/29/2024
Violation issued (HPD, closed)
A
Latest 60 of 91 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedM & M PIPING AND HEATING04/10/2026
DOB NOWPlumbingPermit IssuedPP COUSIN INC10/10/2025
DOB NOWPlumbingPermit IssuedPP COUSIN INC03/21/2025
DOB NOWGeneral ConstructionSigned-offTHREE GLOVES CONSTRUCTION11/20/2024
1 job · most recent 09/11/2025
Gas Water/Sanitary
FiledStatusContractorScope
09/11/2025Permit IssuedM & M PIPING AND HEATINGGas, Water/Sanitary
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
05/18/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/21/2026Pass-Final PL - Up to 9 Requested FloorsPassView ↗
04/13/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
03/10/2026Pass-Final PL - Up to 9 Requested FloorsPassView ↗
08/13/2025Pass-Final General Construction Non-Directive 14PassView ↗
07/31/2025Fail-Final General Construction Non-Directive 14FailView ↗
11/15/2024Pass-Final CND-Occupancy InspectionPassView ↗
10/24/2024Pass-Final CND-Occupancy InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
09/02/2025Fire-Resistant Penetrations and JointsKemba Walcottspecial
07/23/2024Fire-Resistant Penetrations and JointsKemba Walcottspecial
06/12/2024Fire-Resistant Penetrations and JointsKemba Walcottspecial
06/12/2024Structural Stability – Alterations of existing buildingsKemba Walcottspecial
▾Documents — 31 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/24/2026B01058543-I1Request digital key ↗
08/20/2026B01082862-S1Request digital key ↗
08/20/2026B01082862-I1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION2
01/31/2011320246738Open ↗
11/19/2009320094937Open ↗
▸Zoning, Tax Lot & Property Records1
▸BISADDRESS - NEW HOUSE NUMBER APPROVED1
01/31/2011320246738Open ↗
▸Seals & Professional Certifications9
▸DOB NOWSpecial Inspector Seal & Signature4
09/01/2026B01082862-S1Open ↗
08/31/2026B01058543-I1Open ↗
08/31/2026B01058543-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/24/2026B01058543-I1Open ↗
08/20/2026B01082862-S1Open ↗
08/20/2026B01082862-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
01/31/2011320246738Open ↗
11/19/2009320094937Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING2
01/31/2011320246738Open ↗
11/19/2009320094937Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
01/31/2011320246738Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/24/2026B01058543-I1Open ↗
08/20/2026B01082862-I1Open ↗
08/20/2026B01082862-S1Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
01/31/2011320246738Open ↗
11/19/2009320094937Open ↗
▸Approvals, Objections & Sign-offs3
▸BISSCHEDULE A - OCCUPANCY / USE2
01/31/2011320246738Open ↗
01/31/2011320246738Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
11/19/2009320094937Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
01/31/2011320246738Open ↗
11/19/2009320094937Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET2
01/31/2011320246738Open ↗
11/19/2009320094937Open ↗
▸Other Documents1
▸BISPLOT DIAGRAM1
01/31/2011320246738Open ↗