← Back
Primarily 2 family with 1 store or office
828 BROADWAY
BROOKLYN · BIN 3042840
💬 Discuss this project
1930Year Built
3Stories
S2Building Class
C4-4LZoning
2,250 sfGross Floor Area
3Units
Primarily 2 family with 1 store or office · 1,092 sf lot · 2.06 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Permit Issued — active, not yet Signed-off
Floor 3Under Construction10p · 1 filing · 20 docs
Floor 2Under Construction10p · 1 filing · 20 docs
Floor 1Under Construction10p · 1 filing · 20 docs
CellarUnder Construction3p · 1 filing · 20 docs
1 job · most recent 04/17/2026
Gas Water/Sanitary
FiledStatusContractorScope
04/17/2026Permit IssuedAMERICAN STANDARD P&H CORGas, Water/Sanitary
Building Lifecycle
All (16)Filed (5)Permit Issued (3)Signed Off (1)Special Inspection (7)
07/27/2026
Signed off — Alteration
FILE JOB FOR AN EXISTING MIXED USE BUILDING. PROPOSED COMMERCIAL TEA SHOPON 1ST FLOOR WITH NON-COOKING KITCHEN.INTERIOR RENOVATION ON 2ND AND 3RD FLOOR RESIDENTIAL UNITS . NO CHANGE IN EGRESS, OCCUPANCY AND USE.
B01049918-S2
04/17/2026
Filed — Alteration
FILE JOB FOR AN EXISTING MIXED USE BUILDING. PROPOSED COMMERCIAL TEA SHOPON 1ST FLOOR WITH NON-COOKING KITCHEN.INTERIOR RENOVATION ON 2ND AND 3RD FLOOR RESIDENTIAL UNITS . NO CHANGE IN EGRESS, OCCUPANCY AND USE.
B01049918-P2
03/27/2026
Special inspection requirement — Mechanical Systems
FAZAL BANGASH
03/27/2026
Special inspection requirement — Final
Chih Hsu
03/27/2026
Special inspection requirement — Fire-Resistance Rated Construction
Chih Hsu
03/27/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAZAL BANGASH
03/27/2026
Special inspection requirement — Energy Code Compliance Inspections
Chih Hsu
08/04/2025
Special inspection requirement — Fire-Resistance Rated Construction
Chih Hsu
08/04/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAZAL BANGASH
08/02/2025
Filed — Alteration
FILE JOB FOR AN EXISTING MIXED USE BUILDING. PROPOSED COMMERCIAL TEA SHOPON 1ST FLOOR WITH NON-COOKING KITCHEN.INTERIOR RENOVATION ON 2ND AND 3RD FLOOR RESIDENTIAL UNITS . NO CHANGE IN EGRESS, OCCUPANCY AND USE.
B01049918-P1
06/25/2024
Permit issued — Plumbing
B01049918-S1-PL
06/17/2024
Permit issued — Mechanical Systems
B01049918-S2-MS
06/17/2024
Permit issued — General Construction
B01049918-I1-GC
06/12/2024
Filed — Alteration
FILE JOB FOR AN EXISTING MIXED USE BUILDING. PROPOSED COMMERCIAL TEA SHOPON 1ST FLOOR WITH NON-COOKING KITCHEN.INTERIOR RENOVATION ON 2ND AND 3RD FLOOR RESIDENTIAL UNITS . NO CHANGE IN EGRESS, OCCUPANCY AND USE.
B01049918-S2
06/12/2024
Filed — Alteration
FILE JOB FOR AN EXISTING MIXED USE BUILDING. PROPOSED COMMERCIAL TEA SHOPON 1ST FLOOR WITH NON-COOKING KITCHEN.INTERIOR RENOVATION ON 2ND AND 3RD FLOOR RESIDENTIAL UNITS . NO CHANGE IN EGRESS, OCCUPANCY AND USE.
B01049918-I1
06/12/2024
Filed — Alteration
FILE JOB FOR AN EXISTING MIXED USE BUILDING. PROPOSED COMMERCIAL TEA SHOPON 1ST FLOOR WITH NON-COOKING KITCHEN.INTERIOR RENOVATION ON 2ND AND 3RD FLOOR RESIDENTIAL UNITS . NO CHANGE IN EGRESS, OCCUPANCY AND USE.
B01049918-S1
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FOCAL POINT ARCHITECTS & ASS.504/17/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BUILD TEAM803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SAL BUILDERS INCGeneral Contractor207/08/2026
AMERICAN STANDARD P&H CORORP.Plumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BANGASH ASSOCIATES INC8488304/17/2026
HSU & ASSOCIATES8025108/02/2025
BUILDING CONSULTING ENGIN1034106/12/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedAMERICAN STANDARD P&H CORORP.06/25/2024
DOB NOWMechanical SystemsPermit IssuedSAL BUILDERS INC06/17/2024
DOB NOWGeneral ConstructionPermit IssuedSAL BUILDERS INC06/17/2024
BIS—ISSUEDM.Y.F.CONSTRUCTION CO INC.09/18/1991
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
03/27/2026Mechanical SystemsFAZAL BANGASHspecial
03/27/2026FinalChih Hsuprogress
03/27/2026Fire-Resistance Rated ConstructionChih Hsuprogress
03/27/2026Fire-Resistant Penetrations and JointsFAZAL BANGASHspecial
03/27/2026Energy Code Compliance InspectionsChih Hsuprogress
08/04/2025Fire-Resistance Rated ConstructionChih Hsuprogress
08/04/2025Fire-Resistant Penetrations and JointsFAZAL BANGASHspecial
▾Documents — 19 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/17/2026B01049918-P2Request digital key ↗
08/17/2026B01049918-S2Request digital key ↗
08/17/2026B01049918-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications9
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/17/2026B01049918-P2Open ↗
08/17/2026B01049918-P1Open ↗
08/17/2026B01049918-S2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
08/29/2026B01049918-P2Open ↗
08/23/2026B01049918-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/29/2026B01049918-P2Open ↗
08/23/2026B01049918-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/17/2026B01049918-P1Open ↗
08/17/2026B01049918-S2Open ↗
08/17/2026B01049918-I1Open ↗
Showing 3 of 5 on file for this type