← Back
BROOKLYN
490 MONROE STREET
BROOKLYN · BIN 3044772
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
6 Open Violations ▸FDNY Report ↗
Flood zone X
Locations of Work
ArchitectureMechanical
Floor 328p · 1 filing · 20 docs
Floor 227p · 1 filing · 20 docs
Floor 128p · 1 filing · 20 docs
Sub-Basement26p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHRISTOPHER TEETER604/30/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CHRISTOPHER TEETER RA603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HAIAN HONEST RENOVATIONGeneral Contractor303/21/2026
MES CONSTRUCTION CORPPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AK CONSULTING SERVICES, I6198604/30/2024
Building Lifecycle
All (45)Filed (6)Permit Issued (3)Signed Off (1)Violation (16)Inspection (5)Objection (14)
05/05/2026
Violation issued (HPD, open)
A
06/10/2025
Violation issued (HPD, open)
A
07/01/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
05/02/2024
Objection raised — DPL-1
05/02/2024
Objection resolved — Addressed
05/02/2024
Objection raised — Other
05/02/2024
Objection resolved — Addressed
04/30/2024
Filed — Alteration
WORK AS INDICATED ON PLANS. NO CHANGE IN USE OR OCCUPANCY.
B00621451-P2
04/11/2024
Violation issued (HPD, open)
A
01/22/2024
Signed off — Alteration
PLUMBING WORK AS INDICATED ON DRAWINGS.
B00621458-I1
11/21/2023
Violation issued (HPD, closed)
I
10/27/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
10/25/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/18/2023
Permit issued — Plumbing
B00621458-I1-PL
03/24/2023
Violation issued (HPD, open)
A
11/10/2022
Violation issued (HPD, closed)
I
10/19/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/19/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/11/2022
Filed — Alteration
PLUMBING WORK AS INDICATED ON DRAWINGS.
B00621458-P2
09/27/2022
Objection resolved — Addressed
09/14/2022
Objection resolved — Addressed
09/11/2022
Objection raised — Scope
09/08/2022
Objection raised — Scope
09/07/2022
Filed — Alteration
PLUMBING WORK AS INDICATED ON DRAWINGS.
B00621458-P1
09/07/2022
Filed — Alteration
WORK AS INDICATED ON PLANS. NO CHANGE IN USE OR OCCUPANCY.
B00621451-P1
06/22/2022
Permit issued — Plumbing
B00621458-I1-PL
06/15/2022
Permit issued — General Construction
B00621451-I1-GC-CX
03/01/2022
Violation issued (HPD, closed)
I
03/01/2022
Violation issued (HPD, open)
A
11/11/2021
Objection raised — Mechanical
11/11/2021
Objection resolved — Addressed
11/11/2021
Objection raised — Inspections
11/11/2021
Objection resolved — Addressed
11/11/2021
Objection raised — Inspections
11/11/2021
Objection resolved — Addressed
11/10/2021
Filed — Alteration
WORK AS INDICATED ON PLANS. NO CHANGE IN USE OR OCCUPANCY.
B00621451-I1
11/08/2021
Filed — Alteration
PLUMBING WORK AS INDICATED ON DRAWINGS.
B00621458-I1
04/12/2021
Violation issued (HPD, closed)
I
04/12/2021
Violation issued (HPD, open)
A
10/30/2019
Violation issued (HPD, closed)
I
10/18/2018
Violation issued (HPD, closed)
I
11/27/2017
Violation issued (HPD, closed)
I
11/10/2016
Violation issued (HPD, closed)
I
10/13/2015
Violation issued (HPD, closed)
I
02/23/2015
Violation issued (HPD, closed)
I
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offMES CONSTRUCTION CORP10/18/2023
DOB NOWPlumbingSigned-offMES CONSTRUCTION CORP06/22/2022
DOB NOWGeneral ConstructionPermit IssuedHAIAN HONEST RENOVATION06/15/2022
1 project · most recent 04/30/2024
Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
04/30/2024Permit IssuedHAIAN HONEST RENOVATION IAir Conditioning Systems, Heating Systems
Cooling
Daikin EMURA-FTXR12TVJUW(S) 12,000 BTU · Ahu ×28
5MXS48TVJU 48,000 BTU · Condensing Unit ×16
EMURA-FTXR09TVJUW(S) 12,000 BTU · Ahu ×16
EMURA-FTXR18TVJUW(S) 18,000 BTU · Ahu ×4
Heating
Daikin EMURA-FTXR12TVJUW(S) 12,000 BTU · Ahu ×28
5MXS48TVJU 48,500 BTU · Condensing Unit ×16
EMURA-FTXR09TVJUW(S) 12,000 BTU · Ahu ×16
EMURA-FTXR18TVJUW(S) 18,000 BTU · Ahu ×4
1 project · most recent 02/16/2024
General Wiring
FiledStatusContractorScope
02/16/2024CompleteKJK ELECTRIC INCGeneral Wiring
1 project · most recent 04/30/2024
Steel
FiledStatusContractorScope
04/30/2024Permit IssuedHAIAN HONEST RENOVATION ISteel
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
07/01/2024Fail-Final General Construction Non-Directive 14FailView ↗
10/27/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/25/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/19/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/19/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 34
DateRequirementInspectorRole
06/14/2024Mechanical SystemsMAHFUZAR RAHMANspecial
06/14/2024Structural Steel - DetailsMAHFUZAR RAHMANspecial
06/14/2024Footing and FoundationChristopher Teeterprogress
06/14/2024FinalMAHFUZAR RAHMANprogress
06/14/2024Lighting controlsChristopher Teeterenergy_progress
06/14/2024Insulation placement and R valuesChristopher Teeterenergy_progress
06/14/2024Interior lighting powerChristopher Teeterenergy_progress
06/14/2024Fenestration air leakageChristopher Teeterenergy_progress
06/14/2024Lighting in dwelling unitsChristopher Teeterenergy_progress
06/14/2024Fenestration areasChristopher Teeterenergy_progress
06/14/2024Maintenance informationChristopher Teeterenergy_progress
06/14/2024Fenestration and door U-factor and product ratingsChristopher Teeterenergy_progress
06/14/2024HVAC-R and service water heating system controlsChristopher Teeterenergy_progress
06/14/2024HVAC-R and service water heating equipmentChristopher Teeterenergy_progress
06/14/2024Air barrier — testing Christopher Teeterenergy_progress
06/14/2024HVAC-R and service water piping design and insulationChristopher Teeterenergy_progress
10/05/2022Fire-Resistant Penetrations and JointsMAHFUZAR RAHMANspecial
08/24/2022Fenestration and door U-factor and product ratingsChristopher Teeterenergy_progress
08/24/2022Fire-Resistant Penetrations and JointsMAHFUZAR RAHMANspecial
08/24/2022Mechanical SystemsMAHFUZAR RAHMANspecial
08/24/2022Structural Steel - DetailsMAHFUZAR RAHMANspecial
08/24/2022FinalMAHFUZAR RAHMANprogress
08/24/2022Footing and FoundationChristopher Teeterprogress
08/24/2022Lighting controlsChristopher Teeterenergy_progress
08/24/2022Lighting in dwelling unitsChristopher Teeterenergy_progress
Latest 25 of 34.
▾Documents — 75 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/28/2026B00621458-P2Request digital key ↗
08/25/2026B00621451-I1Request digital key ↗
08/25/2026B00621451-P3Request digital key ↗
Showing 3 of 7 on file for this type
▸Applications & Permits1
▸BISPLAN / WORK APPROVAL APPLICATION1
04/03/2020301740301Open ↗
▸Seals & Professional Certifications58
▸DOB NOWProgress Inspector Seal & Signature42
09/05/2026B00621451-I1Open ↗
09/05/2026B00621451-I1Open ↗
09/05/2026B00621451-I1Open ↗
Showing 3 of 42 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/25/2026B00621451-P3Open ↗
08/13/2026B00621451-P1Open ↗
08/13/2026B00621451-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
09/26/2026B00621458-P1Open ↗
09/05/2026B00621451-I1Open ↗
09/05/2026B00621451-I1Open ↗
Showing 3 of 8 on file for this type
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/13/2026B00621458-I1Open ↗
08/13/2026B00621451-P2Open ↗
08/13/2026B00621458-P2Open ↗
Showing 3 of 7 on file for this type
▸Filing & Intake Forms2
▸BISBOROUGH INTAKE FORM2
04/03/2020301740301Open ↗
10/10/2019301740301Open ↗