ECB06/07/2026AT TIME OF INSPECTION OBSERVED SIDEWALK SHED INSTALLED AT EXP# 1. MISSING PARAPET PANEL. OBSERVED PARAPET PANEL LAY ON THE SIDEWALK WITH PROTRUDING NAILS. DETERIORATED MUDSILL ALSO FIRE ESCAPE LADDER OBSTRUCTED$2K due
DOB11/14/2025VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL HGH PRESSURE INSPECTION
DOB11/14/2025VIOLATION ISSUED-FAILURE TO FILE 2024 INTERNAL HGH PRESSURE INSPECTION
DOB11/14/2025VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
ECB07/01/2025AT TIME OF INSPECTION OBSERVED: SIDEWALK SHED INSTALLED AT EXPO# 1 MISSING PROJECT INFORMATION PANEL CONTRARY TO BC 3301.9.2. CREATING AN UNSAFE CONDITION FOR PUBLIC AND OCCUPIED ADJOINING PROPERTIES, SAFETY MO$1K due
ECB06/17/2025AT TIME OF INSPECTION OBSERVED: SIDEWALK SHED IN PLACE EXPO# 1 WITH PERMIT# B00518250-I1-SH UPON REVIEW DEPARTMENT RECORD IT APPEAR SIDEWALK SHED HAVE EXPIRED ON 05/14/2022, CREATING AN UNSAFE CONDITION FOR PUB$625 due
ECB03/16/2025AT THE TIME OF INSPECTION, I OBSERVED SIDEWALK SHED INSTALLED AT EXPOSURE 1, UPON REVIEW OF DOB RECORDS SHED PERMIT EXPIRED 05/14/2022$1K due
ECB03/16/2025AT THE TIME OF INSPECTION, I OBSERVED SIDEWALK SHED INSTALLED AT EXPOSURE 1 WITH NO INFORMATION PANEL POSTED ON THE PARAPET OF THE SHED AS PER BC 3301.9.2.2 SIDEWALK SHED PARAPET INFORMATION PANELS SHALL BE POS$1K due
ECB03/16/2025AT THE TIME OF INSPECTION, I OBSERVED SIDEWALK SHED INSTALLED AT EXPOSURE 1 NOT MAINTAINED IN A SAFE CONDITION, SHED PANEL BULGING, DETERIORATING INCLUDING VERTICAL MEMBER NO PLUMB CONTRARY TO BC 3307.6.5.1 - S$2K due
DOB03/05/2025FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB12/03/2024FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. AT TIME OF INSPECTION, OBSERVED THE EXTERIOR OF THE BUILDING IN STATE OF DISREPAIR. NOTED THE MASONRY BRICK SEPARATION OF THE JOINT BETWEEN THE REAR AND SIDE WALL, STUCCO CRACKED/DETERIORATING NEAR FIRE ESCAPE/ROOF LANDING. CREATING UNSAFE HAZARDOUS CONDITION TO OCCUPANTS AND NEARBY
ECB12/03/2024FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. AT TIME OF INSPECTION, OBSERVED THE EXTERIOR OF THE BUILDING IN STATE OF DISREPAIR. NOTED THE MASONRY BRICK SEPARATION OF THE JOINT BETWEEN THE REAR AND$1K due
ECB10/08/2024AT THE TIME OF MY INSPECTION OF A SIDE WALK SHED PROVIDED TO PROTECT PEDESTRIANS , I OBSERVED THE PERMIT ISSUED ON 05-14-2021 WAS EXPIRED ON 05-14-2022. UPON REVIEW OF DOB RECORDS NO OTHER PERMIT WAS OBTAINED.$6K due
ECB09/23/2024AT THE TIME OF INSPECTION I OBSERVED, SIDEWALK SHED FOR PEDESTRIAN PROTECTION PERMIT HAVE EXPIRED ON 05/14/2022 WITH NO RENEWAL UPON REVIEWING THE DEPARTMENT RECORDS RENEW PERMIT AS REQUIRED$6K due
ECB09/23/2024AT THE TIME OF INSPECTION NO CONSTRUCTION ACTIVITIES, I OBSERVED CONSTRUCTION PROJECT INFORMATION SIGN NOT PROVIDED ON THE SIDEWALK SHED UPPER PARAPET PANEL AT EXPOSURE #1 AS REQUIRED CODEPROVIDE CONSTRUCTION P$6K due
DOB09/23/2024VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
DOB09/23/2024VIOLATION ISSUED-FAILURE TO FILE 2023 INTERNAL HGH PRESSURE INSPECTION
DOB09/23/2024VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL HGH PRESSURE INSPECTION
ECB06/13/2024AT THE TIME OF INSPECTION NO CONSTRUCTION ACTIVITIES, I OBSERVED LIGHTS INSTALLED UNDER SIDEWALK SHED AT 558 HALSEY STREET WITHOUT ANY ELECTRICAL PERMIT UPON REVIEWING THE DEPARTMENT SYSTEM.OBTAIN ELECTRICAL PE$2K due
ECB06/13/2024AT THE TIME OF INSPECTION NO CONSTRUCTION ACTIVITIES, I OBSERVE OCCUPIED BUILDING WITH SIDEWALK SHED INSTALLED AT EXPOSURE#1 AT ADDRESS 558 HALSEY STREET MISSING PROJECT INFORMATION ON THE UPPER PARAPET PANEL$6K due
ECB06/04/2024AT TIME OF INSPECTION 4-STORY MIXED RESIDENTIAL & COMMERCIAL OCCUPIED BUILDING, OBSERVED SIDEWALK SHED AT EXPOSURE #4 WITH PERMIT B00518250-I1-SH EXPIRED 05/14/2022. IT CREATES MAJOR HAZARD FOR PUBLIC AND PROPE$1K due
ECB08/05/2023OBSERVED SIDEWALK SHED AT EXP#1. UPON REVIEW OF DEPARTMENT RECORDS, IT WAS OBSERVED THAT SIDEWALK SHED PERMIT #B00518250-I1 HAS EXPIRED ON 05/14/2022 AND HAS NOT BEEN RENEWED. SIDEWALK SHED PERMIT.$6K due
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2020 INTERNAL HGH PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL HGH PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2021 INTERNAL HGH PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL HGH PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
ECB05/22/2023TIME OF INSPECTION OBSERVED AN ERECTED SIDEWALK SHED AT THE BUILDINGS EXPOSURE 1, NO VALID PERMIT. SIDEWALK SHED IN GOOD CONDITION. HORIZONTAL CROSS MEMBERS NOT AT PROPER HEIGHT 8 FEET AS PER CODE 3307.6.4.7. P$2K due
ECB05/01/2023AT THE TIME OF INSPECTION OBSERVED SIDEWALK SHED IN PLACE FOR PEDESTRIAN PROTECTION, PERMIT HAS EXPIRED ON 5/14/22 UPON REVIEW OF THE DEPARTMENT RECORDS.RENEW PERMIT AS REQUIRED.$1K due
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL HIGH PRESSURE INSPECTION
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 INTERNAL HIGH PRESSURE INSPECTION
DOB12/22/2021FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB12/16/2021FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES.AT TIME OF INSPECTION AND OBSERVED AT HALSEY ST SIDE AT 4TH FLOOR FACADE NEXT TO WINDOWS BRICK WORK IS BULGING(EXP#1)AT EXP #2 STUCCO MISSING OR SPALLING EXPO$1K due
DOB11/10/2021FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB10/07/2021EXPIRED PERMIT SIDEWALK SHED. NOTE: AT THE TIME OF MY INSPECTION OF A 4 STY BLDG,I OBSERVED SIDEWALK SHED IN PLACE. DID A SEARCH IN BIS WHICH ALERTED ME THAT SIDEWALK SHED PERMIT HAS BEING EXP FROM 9-9-2021.$1K due
ECB10/07/2021SIDEWALK SHED DOES NOT MEET CODE SPECIFICATION. NOTE: AT THE TIME OF MY INSPECTION OF A 4 STY BLDG. I OBSERVED SIDEWALK SHED IN PLACE W/THE FOLLOWING OBJECTION INOPERABLE LIGHT BULBS THIS CREATES A HAZARDOUS$2K due
ECB09/23/2021FAILURE TO MAINTAIN BUILDING WALL(S)OR APPURTENANCES AT THE TIME OF INSPECTION AND OBSERVED AT EXP#1 ON RIGHT SIDE NEXT TO 4TH FLOORS WINDOWBRICKWORK IS BULGING AND AT EXP 4 STUCCO IS MISSING EXPOSUED BRICKS,PA$6K due
DOB09/15/2021FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB08/13/2021FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTED: OBSERVED AT EXP#1,4TH FL RIGHT SIDE OF WINDOW OVER THE FRONT ENTRY DOOR,BRICKWALL BULGING OUTSIDE. AT EXP#1&2. PAINT SPALLING,BRICKS DEFACED,DETERIORATED$6K due
ECB06/18/2021FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. AT THE TIME OF INSPECTION & OBSERVED AT EXP#1,4TH FL LEVEL EXTERIOR BRICK WORK IS BULGING OUTWARD,AT EXP#2 MISSING STUCCO SURFACE EXPOSURE BRICKS/MISSING MASONRY$6K due
DOB06/09/2021FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
ECB03/10/2021FAILURE TO MAINTAIN BLDG WALL(S) OR APPURTENANCES.NOTE:@TIME OF INSP,OBSERVED@EXP1&4@THIS LOCATION,FRONT WALL IN COMPLETE DISREPAIR&BULGING OUT@4FL LEVEL.MAINTAIN EXTERIOR BLDG WALL/MAKE WALL SAFE IMMEDIATELY.$2K due
DOB03/16/2020VIOLATION ISSUED - FAILURE TO FILE 2017 INTERNAL HIGH PRESSURE BOILER INSPECTION
DOB11/08/2019VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
DOB04/06/2018VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
DOB08/09/2017FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB08/09/2017FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB08/09/2017FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB08/09/2017FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB08/09/2017FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB02/24/2017VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
DOB10/01/2015VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
DOB03/03/2015VIOLATION ISSUED FOR FAILURE TO FILE 2013 ANNUAL HIGH PRESSURE BOILER INSPECTION
DOB03/03/2015VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
DOB05/15/2014VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
DOB03/01/2013VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
DOB12/13/2011VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
DOB12/31/2009V-DOB VIOLATION - ACTIVE
DOB01/01/2009V-DOB VIOLATION - ACTIVE
DOB01/03/2008V-DOB VIOLATION - ACTIVE
DOB01/19/2007V-DOB VIOLATION - ACTIVE
DOB01/06/2006V-DOB VIOLATION - ACTIVE
DOB01/31/2005V-DOB VIOLATION - ACTIVE
DOB02/13/2004V-DOB VIOLATION - ACTIVE
DOB03/19/2003V-DOB VIOLATION - ACTIVE
DOB03/26/2002V-DOB VIOLATION - ACTIVE
DOB02/07/2000V-DOB VIOLATION - ACTIVE
DOB09/16/1997V-DOB VIOLATION - ACTIVE
DOB02/10/1997V-DOB VIOLATION - ACTIVE
DOB08/29/1995V-DOB VIOLATION - ACTIVE
DOB07/25/1994V-DOB VIOLATION - ACTIVE
ECB05/16/20174A,5A,19B,24B,50,50A,50B,51,36. 50-BOILER ROOM LIGHTS DEFECTIVE; 50A-HWH SAFETY DISCHARGE PIPE MISSING; 50B-FLUE NOT INCREASED FOR BOILER AND HWH.Nothing owed — awaiting certificate of correction
ECB05/16/20174A,5A,24B,50,51,19B,36,50A. 50-STORAGE AND DEBRIS IN BOILER ROOM; 50A-FLUE NOT INCREASED FOR BOILER AND TWO HWHS. CROWN BOILER 37,000 BTUSNothing owed — awaiting certificate of correction
ECB05/16/2017B154,50A,50B,51. FULTON V.T. BOILER; 10HP,NB43028. HP STEAM; 50A-SEVERE THERMAL WEAR CORROSION AND PARTIAL COLLAPSE OF FLUE RUN TO THE CHIMNEY BASE. REPLACE ENTIRE FLUE PIPE ASSEMBLY AND REMOVE DRAFT INDUCER.Nothing owed — awaiting certificate of correction
ECB05/16/20174A,5A,15,19B,24B,34B,36,38,50,51. 50-CHIMNEY BASE CLEANOUT DOOR BRICKED UP. CROWN 37,000 BTUS.Nothing owed — awaiting certificate of correction
ECB05/16/2017WEIL MCLAIN BOILER REMOVED AND CROWN BOILER 37,000 BTU'S INSTALLED W/O BOILER PERMIT.Nothing owed — awaiting certificate of correction
ECB01/22/201018B.32A.38.48.Nothing owed — awaiting certificate of correction