← Back
Two family brick
545 MAC DONOUGH STREET
BROOKLYN · BIN 3047025
💬 Discuss this project
1901Year Built
2Stories
B1Building Class
R6BZoning
2,318 sfGross Floor Area
2Units
Two family brick · 1,800 sf lot · 1.29 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalMechanical
Roof4p · 1 filing · 20 docs
Floor 11p · 1 filing · 20 docs
Basement4p · 1 filing · 20 docs
2 jobs · most recent 10/04/2024
General Wiring
FiledStatusContractorScope
10/04/2024CompleteKWONG MING ELECTRIC INCGeneral Wiring
12/11/2023CompleteKWONG MING ELECTRIC INC3 meters, 3 new_meters
Building Lifecycle
All (79)Filed (4)Permit Issued (4)Signed Off (3)Inspection (5)Objection (36)Special Inspection (27)
03/27/2025
Signed off — Alteration
HEREBY FILING FOR THE RENOVAITON OF 2 FAMILY BROWNSTONE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00978243-S1
12/16/2024
Signed off — Alteration
HEREBY FILING FOR THE RENOVAITON OF 2 FAMILY BROWNSTONE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00978243-I1
11/21/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
11/13/2024
Signed off — Alteration
HEREBY FILING FOR THE RENOVAITON OF 2 FAMILY BROWNSTONE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00978243-S2
11/06/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Stephen Shishko
11/06/2024
Special inspection requirement — Mechanical Systems
Stephen Shishko
11/06/2024
Special inspection requirement — Energy Code Compliance Inspections
Stephen Shishko
11/06/2024
Special inspection requirement — Final
Stephen Shishko
11/06/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Stephen Shishko
11/06/2024
Special inspection requirement — HVAC-R and service water heating system controls
Stephen Shishko
11/06/2024
Special inspection requirement — HVAC-R and service water heating equipment
Stephen Shishko
11/02/2024
Filed — Alteration
HEREBY FILING FOR THE RENOVAITON OF 2 FAMILY BROWNSTONE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00978243-P1
11/01/2024
Special inspection requirement — HVAC-R and service water heating system controls
Stephen Shishko
11/01/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Stephen Shishko
11/01/2024
Special inspection requirement — Mechanical Systems
Stephen Shishko
11/01/2024
Special inspection requirement — Energy Code Compliance Inspections
Stephen Shishko
11/01/2024
Special inspection requirement — Final
Stephen Shishko
11/01/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Stephen Shishko
11/01/2024
Special inspection requirement — HVAC-R and service water heating equipment
Stephen Shishko
10/04/2024
Permit issued — Mechanical Systems
B00978243-S2-MS
07/30/2024
Permit issued — General Construction
B00978243-I1-GC-CX
05/31/2024
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
05/31/2024
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
05/31/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/31/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
04/23/2024
Permit issued — Plumbing
B00978243-S1-PL
04/16/2024
Permit issued — Foundation
B00978243-I1-GC-CX
03/14/2024
Objection resolved — Addressed
03/08/2024
Objection resolved — Addressed
03/08/2024
Objection resolved — Addressed
03/07/2024
Objection raised — Scope
03/07/2024
Objection raised — Scope
03/06/2024
Objection resolved — Addressed
03/06/2024
Objection resolved — Addressed
03/05/2024
Objection resolved — Addressed
03/05/2024
Objection resolved — Addressed
03/05/2024
Objection resolved — Addressed
03/05/2024
Objection resolved — Addressed
02/21/2024
Objection resolved — Addressed
02/21/2024
Objection resolved — Addressed
02/21/2024
Objection resolved — Addressed
02/21/2024
Objection resolved — Addressed
02/21/2024
Objection resolved — Addressed
02/20/2024
Objection resolved — Addressed
02/20/2024
Objection resolved — Addressed
02/19/2024
Objection resolved — Addressed
02/19/2024
Objection resolved — Addressed
01/19/2024
Objection raised — Scope
01/19/2024
Objection raised — Scope
01/19/2024
Objection raised — Admin
01/19/2024
Objection raised — Fire_Protection
01/19/2024
Objection raised — Scope
01/19/2024
Objection raised — Admin
01/19/2024
Objection raised — Scope
01/19/2024
Objection raised — Scope
01/18/2024
Objection raised — Fire_Protection
01/18/2024
Objection raised — Structural
01/18/2024
Objection raised — Other
01/18/2024
Objection raised — Other
01/18/2024
Objection raised — Scope
Latest 60 of 79 events.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/19/2017$950K—— → —$410/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
REAL CREATIVE MOTION ENGINEERING SE311/02/2024
DESIDERATUM DESIGN LLC101/09/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JENNY FLORES EXPEDITING403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MATIC CONSTRUCTION CORPGeneral Contractor707/08/2026
AAA TOTAL PLUMBING, INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NEW AGE ENGINEERING PLLC7746311/02/2024
MOORE ENG. OF NY, DPC9134101/09/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offMATIC CONSTRUCTION CORP10/04/2024
DOB NOWGeneral ConstructionSigned-offMATIC CONSTRUCTION CORP07/30/2024
DOB NOWPlumbingSigned-offAAA TOTAL PLUMBING, INC04/23/2024
DOB NOWFoundationSigned-offMATIC CONSTRUCTION CORP04/16/2024
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
11/21/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
05/31/2024Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
05/31/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
05/31/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/31/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 27
DateRequirementInspectorRole
11/06/2024Fire-Resistant Penetrations and JointsStephen Shishkospecial
11/06/2024Mechanical SystemsStephen Shishkospecial
11/06/2024Energy Code Compliance InspectionsStephen Shishkoprogress
11/06/2024FinalStephen Shishkoprogress
11/06/2024HVAC-R and service water piping design and insulationStephen Shishkoenergy_progress
11/06/2024HVAC-R and service water heating system controlsStephen Shishkoenergy_progress
11/06/2024HVAC-R and service water heating equipmentStephen Shishkoenergy_progress
11/01/2024HVAC-R and service water heating system controlsStephen Shishkoenergy_progress
11/01/2024Fire-Resistant Penetrations and JointsStephen Shishkospecial
11/01/2024Mechanical SystemsStephen Shishkospecial
11/01/2024Energy Code Compliance InspectionsStephen Shishkoprogress
11/01/2024FinalStephen Shishkoprogress
11/01/2024HVAC-R and service water piping design and insulationStephen Shishkoenergy_progress
11/01/2024HVAC-R and service water heating equipmentStephen Shishkoenergy_progress
12/26/2023Energy Code Compliance InspectionsStephen Shishkoprogress
12/26/2023Fire-Resistance Rated ConstructionStephen Shishkoprogress
12/26/2023Fenestration areasStephen Shishkoenergy_progress
12/26/2023Air barrier - visual inspectionStephen Shishkoenergy_progress
12/26/2023Lighting controlsStephen Shishkoenergy_progress
12/26/2023Interior lighting powerStephen Shishkoenergy_progress
12/26/2023Fenestration air leakageStephen Shishkoenergy_progress
12/26/2023Fire-Resistant Penetrations and JointsStephen Shishkospecial
12/26/2023Fenestration and door U-factor and product ratingsStephen Shishkoenergy_progress
12/15/2023Footing and FoundationChristine Hobsonprogress
12/15/2023Structural Steel - DetailsChristine Hobsonspecial
Latest 25 of 27.
▾Documents — 26 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/26/2026B00978243-P1Request digital key ↗
08/26/2026B00978243-S2Request digital key ↗
08/26/2026B00978243-S1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications17
▸DOB NOWProgress Inspector Seal & Signature9
09/02/2026B00978243-S2Open ↗
09/02/2026B00978243-S2Open ↗
09/02/2026B00978243-S2Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/26/2026B00978243-S2Open ↗
08/13/2026B00978243-P1Open ↗
08/13/2026B00978243-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/02/2026B00978243-S2Open ↗
08/30/2026B00978243-I1Open ↗
08/30/2026B00978243-I1Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/26/2026B00978243-S2Open ↗
08/13/2026B00978243-I1Open ↗
08/13/2026B00978243-P1Open ↗
Showing 3 of 4 on file for this type
▸Inspections & Test Reports1
▸DOB NOWGeotechnical Report (BC 1803.6)1
08/13/2026B00978243-I1Open ↗