← Back
Single or multiple dwelling with stores or offices
511 QUINCY STREET
BROOKLYN · BIN 3050785
💬 Discuss this project
1931Year Built
3Stories
S9Building Class
R6BZoning
4,830 sfGross Floor Area
4Units
4 Open Violations 2 unresolved · 2 paperwork only ▸FDNY Report ↗
Single or multiple dwelling with stores or offices · Owner of record: 511 QUINCY LLC · 2,300 sf lot · 2.1 FAR built · Flood zone X
Locations of Work
Mechanical
Floor 11p · 1 filing · 6 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ORTIZ DELI GROCERY NY CORP503/22/2026
511 QUINCY LLC203/22/2026
DUCOS REALTY, INC.103/22/2026
DUCUS REALTY INC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/23/2017$1.4M—DUCOS REALTY INC → 511 QUINCY LLC$290/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BITOPI CONSULTANTS LLC103/25/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUPERIOR FIRE CONTROL103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SUPERIOR FIRE CONTROL INCGeneral Contractor303/21/2026
CANALE, WILLIAMElectrical103/21/2026
DACON, CHADElectrical103/21/2026
FRANCIS CAPORALEElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BITOPI CONSULTANTS LLC7036103/25/2025
Building Lifecycle
All (17)Filed (1)Permit Issued (1)Violation (12)Special Inspection (3)
12/03/2025
Violation issued (ECB, open)
Zoning
12/03/2025
Violation issued (ECB, open)
Construction
04/08/2025
Permit issued — Mechanical Systems
B01184848-I1-MS
03/25/2025
Filed — Alteration
Filing to install the Deli Kitchen Hood and Ductwork as per plans. No change in use, egress, or occupancy.
B01184848-I1
02/21/2025
Special inspection requirement — Tenant Protection Plan Compliance
KAMRUL AHSAN
02/21/2025
Special inspection requirement — Mechanical Systems
KAMRUL AHSAN
02/21/2025
Special inspection requirement — Final
KAMRUL AHSAN
12/11/2024
Violation issued (FDNY_ORDER, closed)
12/11/2024
Violation issued (FDNY_ORDER, closed)
12/11/2024
Violation issued (FDNY_ORDER, closed)
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/01/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/31/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/14/2007
Violation issued (ECB, closed)
Construction
01/23/2007
Violation issued (ECB, closed)
Boilers
01/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/04/2005
Violation issued (HPD, open)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedSUPERIOR FIRE CONTROL INC04/08/2025
1 project · most recent 03/25/2025
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
03/25/2025Permit IssuedSUPERIOR FIRE CONTROL INCVentilation Systems
Ventilation
Pen Vent USBI18DD 2,000 CFM · Kitchen Exhaust ×1
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
02/21/2025Tenant Protection Plan ComplianceKAMRUL AHSANspecial
02/21/2025Mechanical SystemsKAMRUL AHSANspecial
02/21/2025FinalKAMRUL AHSANprogress
▾Documents — 26 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/22/2026B01184848-I1Request digital key ↗
▸Applications & Permits5
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION2
06/14/2017310037466Open ↗
06/14/2017310037466Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION2
07/20/2017310037466Open ↗
06/13/2017310037466Open ↗
▸BISWORK PERMIT APPLICATION1
11/16/2007310037466Open ↗
▸Seals & Professional Certifications10
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
07/20/2017310037466Open ↗
10/16/2007310037466Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026B01184848-I1Open ↗
09/01/2026B01184848-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
10/16/2007310037466Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
07/20/2017310037466Open ↗
▸BISProfessional and Owner Certification (POC3)1
07/20/2017310037466Open ↗
▸BISPC FULL REPORT1
10/16/2007310037466Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/22/2026B01184848-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
09/01/2026B01184848-I1Open ↗
▸Trade Schedules & Equipment3
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT3
07/24/2017310037466Open ↗
07/20/2017310037466Open ↗
10/16/2007310037466Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
10/16/2007310037466Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/22/2026B01184848-I1Open ↗
▸Inspections & Test Reports1
▸BISNOTIF.-PROPOSED STEAM/HOT WATER INSPECTION1
10/16/2007310037466Open ↗
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
10/16/2007310037466Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
07/20/2017310037466Open ↗
11/16/2007310037466Open ↗
▸Filing & Intake Forms1
▸BISADDITIONAL INFORMATION1
07/20/2017310037466Open ↗