← Back
Two family converted from one family
168 HERKIMER STREET
BROOKLYN · BIN 3053965
💬 Discuss this project
1901Year Built
3Stories
B3Building Class
R6BZoning
2,604 sfGross Floor Area
2Units
Two family converted from one family · Owner of record: 168HERKIMER LLC · 1,550 sf lot · 1.68 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Permit Issued — active, not yet Signed-off
Floor 3Under Construction21p · 2 filings · 20 docs
Floor 2Under Construction21p · 2 filings · 20 docs
Floor 1Under Construction21p · 2 filings · 20 docs
CellarUnder Construction25p · 2 filings · 20 docs
BasementUnder Construction6p · 1 filing · 19 docs
Sub-BasementUnder Construction14p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
168HERKIMER1006/27/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/06/2024$1.4M—Private party → 168HERKIMER LLC$528/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CONCORD CONSULTING ENGINEERING PC209/09/2025
ALNOUR CONSULTING109/09/2025
168BHERKIMER LLC109/05/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
S M EXPEDITING803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CHELSEA DEVELOPERS LLCGeneral Contractor204/09/2026
FOUR STREETS COOL AIR INCGeneral Contractor106/27/2026
ALL PRO PLBG & HTG INCPlumbing106/27/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ALNOUR CONSULTING ENGINEE607409/09/2025
Building Lifecycle
All (8)Filed (4)Permit Issued (4)
06/25/2026
Permit issued — Mechanical Systems
B01266994-S1-MS
06/24/2026
Permit issued — Plumbing
B01266994-I1-PL
03/18/2026
Permit issued — Structural
B01266965-S1-ST
02/17/2026
Permit issued — General Construction
B01266965-I1-GC
09/09/2025
Filed — Alteration
THE SCOPE OF WORK INCLUDES BUT NOT LIMITED TO THE FOLLOWING: FURNISH AND INSTALL AIR-CONDITIONING UNITS, HEAT PUMP, FANS, HEATERS ETC. AT LOCATIONS AS SHOWN ON MECHANICAL DRAWINGS. PROVIDE ALL OTHER WORK ITEMS INDICATED ON DRAWINGS AND SPECIFICATIONS
B01266994-I1
09/09/2025
Filed — Alteration CO
STRUCTURAL WORK IN CONJUNCTION WITH ARCHITECTURAL APPLICATION FORINTERIOR RENOVATION
B01266965-S1
09/09/2025
Filed — Alteration
THE SCOPE OF WORK INCLUDES BUT NOT LIMITED TO THE FOLLOWING: FURNISH AND INSTALL AIR-CONDITIONING UNITS, HEAT PUMP, FANS, HEATERS ETC. AT LOCATIONS AS SHOWN ON MECHANICAL DRAWINGS. PROVIDE ALL OTHER WORK ITEMS INDICATED ON DRAWINGS AND SPECIFICATIONS
B01266994-S1
09/05/2025
Filed — Alteration CO
STRUCTURAL WORK IN CONJUNCTION WITH ARCHITECTURAL APPLICATION FORINTERIOR RENOVATION
B01266965-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedFOUR STREETS COOL AIR INC06/25/2026
DOB NOWPlumbingPermit IssuedALL PRO PLBG & HTG INC06/24/2026
DOB NOWStructuralPermit IssuedCHELSEA DEVELOPERS03/18/2026
DOB NOWGeneral ConstructionPermit IssuedCHELSEA DEVELOPERS02/17/2026
1 project · most recent 09/09/2025
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
09/09/2025Permit IssuedFOUR STREETS COOL AIR INCHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MSZ-GL12NA 14,400 BTU · Ahu ×3
PEAD-A24AA9 24,000 BTU · Vrf Indoor ×3
Berko Wall Mounted FRC4020 13,650 BTU · Electric Heater ×1
Wall mounted FFCH548 6,825 BTU · Electric Heater ×1
Wall mounted FRC4020 6,825 BTU · Electric Heater ×1
1 project · most recent 09/09/2025
Storm Water/Sanitary
FiledStatusContractorScope
09/09/2025Permit IssuedALL PRO PLBG & HTG INCStorm, Water/Sanitary
1 project · most recent 08/24/2026
General Wiring
FiledStatusContractorScope
08/24/2026Permit IssuedRONEY ELECTRIC INCGeneral Wiring
1 project · most recent 09/09/2025
Steel Concrete Masonry Wood
FiledStatusContractorScope
09/09/2025Permit IssuedCHELSEA DEVELOPERS LLCSteel, Concrete, Masonry, Wood
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
07/20/2026Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
07/20/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
07/20/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/20/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
07/15/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 17
DateRequirementInspectorRole
09/03/2025MasonryNouredine Benabdelhakspecial
08/06/2025Concrete - Cast-In-PlaceNouredine Benabdelhakspecial
08/06/2025Post-installed AnchorsNouredine Benabdelhakspecial
08/06/2025Structural Steel - DetailsNouredine Benabdelhakspecial
08/06/2025Structural Steel - High Strength BoltingNouredine Benabdelhakspecial
08/06/2025Structural Steel - WeldingNouredine Benabdelhakspecial
08/06/2025FinalNouredine Benabdelhakprogress
08/06/2025Mechanical SystemsNouredine Benabdelhakspecial
08/06/2025Fire-Resistant Penetrations and JointsNouredine Benabdelhakspecial
08/06/2025FinalNouredine Benabdelhakprogress
08/06/2025Energy Code Compliance InspectionsNouredine Benabdelhakprogress
08/06/2025Electrical motors and elevatorsNouredine Benabdelhakenergy_progress
08/06/2025HVAC-R and service water heating equipmentNouredine Benabdelhakenergy_progress
08/06/2025HVAC-R and service water piping design and insulationNouredine Benabdelhakenergy_progress
08/06/2025Maintenance informationNouredine Benabdelhakenergy_progress
08/06/2025Structural Stability – Alterations of existing buildingsNouredine Benabdelhakspecial
08/06/2025HVAC-R and service water heating system controlsNouredine Benabdelhakenergy_progress
▾Documents — 34 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/20/2026B01266994-S1Request digital key ↗
08/20/2026B01266994-I1Request digital key ↗
08/20/2026B01266965-S1Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B01266965-I1Open ↗
▸Seals & Professional Certifications21
▸DOB NOWSpecial Inspector Seal & Signature9
09/23/2026B01266994-S1Open ↗
09/23/2026B01266994-S1Open ↗
09/01/2026B01266965-S1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWProgress Inspector Seal & Signature8
09/23/2026B01266994-S1Open ↗
09/23/2026B01266994-S1Open ↗
09/23/2026B01266994-S1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/20/2026B01266994-S1Open ↗
08/20/2026B01266994-I1Open ↗
08/13/2026B01266965-I1Open ↗
Showing 3 of 4 on file for this type
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026B01266965-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form4
08/20/2026B01266994-S1Open ↗
08/20/2026B01266994-I1Open ↗
08/13/2026B01266965-S1Open ↗
Showing 3 of 4 on file for this type
▸Inspections & Test Reports2
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026B01266965-I1Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026B01266965-I1Open ↗
▸Other Documents1
▸DOB NOWProperty Ownership Certification1
08/13/2026B01266965-I1Open ↗