← Back
Two family converted from one family
129 VANDERBILT AVENUE
BROOKLYN · BIN 3054250
💬 Discuss this project
1855Year Built
3Stories
B3Building Class
R5BZoning
3,900 sfGross Floor Area
2Units
Two family converted from one family · 2,000 sf lot · 1.95 FAR built · Flood zone X
Locations of Work
ArchitectureGeneral
Roof1p · 1 filing · 7 docs
Floor 21p · 1 filing · 7 docs
Floor 1
Cellar2p · 1 filing · 7 docs
Basement1p · 1 filing · 7 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RS DESIGN ASSOCIATES, INC.105/21/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
RS DESIGN ASSOCIATES203/21/2026
Building Lifecycle
All (60)Filed (1)Objection (50)Special Inspection (9)
08/13/2026
Objection resolved — Resolved
07/10/2026
Objection raised — Scope
04/25/2026
Objection resolved — Resolved
04/24/2026
Objection resolved — Resolved
04/24/2026
Objection resolved — Resolved
04/24/2026
Objection resolved — Addressed
04/24/2026
Objection resolved — Resolved
03/18/2026
Objection raised — Cost
03/02/2026
Objection resolved — Addressed
02/08/2026
Objection resolved — Addressed
02/08/2026
Objection resolved — Addressed
09/17/2025
Objection raised — Scope
09/17/2025
Objection raised — Scope
08/26/2025
Objection raised — Scope
08/14/2025
Objection resolved — Addressed
08/04/2025
Objection resolved — Addressed
08/04/2025
Special inspection requirement — Insulation placement and R values
08/04/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
08/04/2025
Special inspection requirement — Interior lighting power
08/04/2025
Special inspection requirement — Concrete - Cast-In-Place
08/04/2025
Special inspection requirement — Lighting controls
08/04/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
08/04/2025
Special inspection requirement — Lighting in dwelling units
08/02/2025
Objection resolved — Addressed
08/02/2025
Objection resolved — Addressed
08/01/2025
Objection resolved — Addressed
07/21/2025
Objection raised — Admin
07/21/2025
Objection raised — Zoning
07/21/2025
Objection raised — Scope
07/21/2025
Objection raised — Zoning
07/21/2025
Objection raised — Fire_Protection
07/17/2025
Objection resolved — Addressed
07/17/2025
Objection resolved — Addressed
07/17/2025
Objection resolved — Addressed
07/01/2025
Objection raised — Fire_Protection
07/01/2025
Objection raised — Admin
07/01/2025
Objection raised — Fire_Protection
06/28/2025
Objection resolved — Addressed
06/28/2025
Objection resolved — Addressed
06/15/2025
Objection resolved — Addressed
06/01/2025
Objection resolved — Addressed
06/01/2025
Objection resolved — Addressed
06/01/2025
Objection resolved — Addressed
06/01/2025
Objection resolved — Resolved
06/01/2025
Objection resolved — Addressed
05/23/2025
Objection raised — Scope
05/23/2025
Objection raised — Zoning
05/23/2025
Objection raised — Scope
05/23/2025
Objection raised — Scope
05/23/2025
Objection raised — Zoning
05/23/2025
Objection raised — Zoning
05/23/2025
Objection raised — Other
05/23/2025
Objection raised — Scope
05/23/2025
Objection raised — Zoning
05/23/2025
Objection raised — Zoning
05/23/2025
Objection raised — Scope
05/22/2025
Objection raised — Admin
05/21/2025
Filed — Alteration
Create rear year extension at Basement and 1st floor with deck and stair to rear yard.
B01219649-I1
05/21/2025
Special inspection requirement — Energy Code Compliance Inspections
ERROL CRAWFORD
05/21/2025
Special inspection requirement — Fire-Resistance Rated Construction
ERROL CRAWFORD
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISOTISSUEDRS DESIGN ASSOCIATES INC05/10/2019
BISOTISSUEDRS DESIGN ASSOCIATES INC02/13/2018
BISOTISSUEDRS DESIGN ASSOCIATES INC11/16/2017
BISOTISSUEDRS DESIGN ASSOCIATES INC06/19/2015
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
08/04/2025Insulation placement and R values—energy_progress
08/04/2025Fire-Resistant Penetrations and Joints—special
08/04/2025Interior lighting power—energy_progress
08/04/2025Concrete - Cast-In-Place—special
08/04/2025Lighting controls—energy_progress
08/04/2025Fenestration and door U-factor and product ratings—energy_progress
08/04/2025Lighting in dwelling units—energy_progress
05/21/2025Energy Code Compliance InspectionsERROL CRAWFORDprogress
05/21/2025Fire-Resistance Rated ConstructionERROL CRAWFORDprogress
▾Documents — 19 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/15/2026B01219649-I1Request digital key ↗
▸Applications & Permits6
▸BISWORK PERMIT APPLICATION4
05/15/2019320955917Open ↗
02/14/2018320955917Open ↗
11/20/2017320955917Open ↗
Showing 3 of 4 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION1
09/11/2014320955917Open ↗
▸DOB NOWLPC Approval/Permit1
08/13/2026B01219649-I1Open ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026B01219649-I1Open ↗
▸Seals & Professional Certifications4
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
09/11/2014320955917Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
09/11/2014320955917Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
09/11/2014320955917Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/21/2026B01219649-I1Open ↗
▸Approvals, Objections & Sign-offs2
▸BISLANDMARKS APPROVAL1
09/11/2014320955917Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
09/11/2014320955917Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
09/11/2014320955917Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
09/11/2014320955917Open ↗
▸Other Documents3
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/15/2026B01219649-I1Open ↗
▸DOB NOWPlot Diagram1
08/13/2026B01219649-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026B01219649-I1Open ↗