ECB02/13/2025FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS #39091092X ISSUED ON 07/26/2023, AND FAILURE TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28.201.1 AND 1 RCNY 102-01(D)(2). AN ACCEPTABLE CERT$1K due
DOB09/27/2023FTM BUILDING & PARTS THEREOF IN A CODE COMPLIANT MANNER: ATOI, THE KITCHEN CEILING WAS OBSERVED BOWING/BULGING AT THE REAR/EXP-3 AT APT # 3.
DOB09/27/2023FTM BLDNG IN A CODE COMPLIANT MANNER: STEP TREADS/LNDINGS DISPLACED & SAGGING 2" TO 5" INCHS TRH OUT THE RISE AT THE CMMN STAIRWLL. STEP TREADS NOT SECURED, W/ MVMNT UNDER FOOT AT THE TOP OF 4TH FLR RISE. STAIRWLL BANISTER NOT SECURED AT 4TH FLR. FLRS SAGGING 2" TO 5" INCHS AT KITCH/DINNING RM AREA & CNTER BEDRM TWRDS CMMON STAIRWLL AT APT #
HPD08/03/2023§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT VESTIBULE DOOR AT PUBLIC HALL, 1st STORY
HPD08/03/2023§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR LOCK AT VESTIBULE AT PUBLIC HALL, 1st STORY
HPD08/03/2023§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AND ALL WALLS AT PUBLIC HALL, 4th STORY
HPD08/03/2023§ 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. MAKE STATIONARY THE IRON LADDER LEADING TO SCUTTLE OPENING IN ROOF AT PUBLIC HALL, 4th STORY
HPD08/03/2023§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE KITCHEN LOCATED AT APT 3, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD08/03/2023§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 3, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD08/03/2023§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 3, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
ECB07/26/2023WORK WITHOUT PERMIT FOR ENCLOSED OPENING OF THE MIDDLE ROOM WALL WITH SHEETROCK., OBTAIN ALL PERMITS$1K due
HPD07/17/2023HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD07/17/2023§ 213, SUBD. 5 M/D LAW DISCONTINUE USE OF INTERIOR ROOM FOR LIVING OR PROVIDE A SINGLE OPENING OF AT LEAST 60 PERCENT OF AREA OF THE PARTITION TO ROOM HAVING WINDOW OPENING DIRECTLY TO STREET OR YARD INTERIOR ROOM IN THE 2nd ROOM FROM NORTH LOCATED AT APT 3, 4th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD05/22/2023§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE KITCHEN LOCATED AT APT 3, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD05/22/2023§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE SILL AND APRON OF THE 2ND WINDOW FROM WEST AT NORTH IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 3, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD05/22/2023§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 3, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD05/22/2023§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 3, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD05/22/2023§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 4th ROOM FROM NORTH AT WEST LOCATED AT APT 3, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD05/22/2023§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE (INOPERATIVE)LOWER SASH AT THE 2ND WINDOW FROM WEST AT NORTH IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 3, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD05/22/2023§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE (STUCK IN SHUT POSITION) THE LOWER SASH OF THE 2ND WINDOW FROM EAST AT SOUTH IN THE 4th ROOM FROM NORTH AT WEST LOCATED AT APT 3, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD05/22/2023§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE THE LOWER SASH OF THE 2ND WINDOW FROM WEST AT NORTH IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 3, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD05/22/2023§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 3, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD05/22/2023§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE OF THE LOWER SASH AT THE 2ND WINDOW FROM WEST AT NORTH IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 3, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD05/21/2023§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 3, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD05/21/2023§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT UPPER SASH AT WINDOW IN THE KITCHEN LOCATED AT APT 3, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD05/21/2023§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER SASH AT WINDOW IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 3, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD03/11/2021§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED
HPD03/11/2021§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING.
HPD03/11/2021§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING AT PUBLIC HALL, 1st STORY
HPD03/11/2021§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY
HPD09/08/2020§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT PUBLIC HALL, 4th STORY
HPD09/08/2020§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3, 4th STORY
HPD09/08/2020§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3, 4th STORY
HPD09/08/2020§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE SOUTH WALL IN THE KITCHEN LOCATED AT APT 3, 4th STORY, APARTMENT AT SOUTH
DOB12/13/2011VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
DOB12/31/2009V-DOB VIOLATION - ACTIVE
ECB03/08/2010(MISC)BC3309.4&27-1032FAILURE TO PRESERVE & PROTECT ADJOINING STRUCTURE AFFECTED BY EXCAVATION OPERATIONS.THERE IS A 9-11FT SHEAR CUT @ THE REAR O FTHE PROPERTY & @ EXPOSURE 2 THE ADJOINING PROPERTY & IS UNDERMNothing owed — awaiting certificate of correction
ECB03/08/2010FAILURE TO PROVIDE PROTECTION@ SIDES OF ECAVATION.THERE IS A 9-11FT SHEAR CUT @ THE REAR OF THE PROPERTY EXPOSURES 2 & 3 & NO PROTECTION PROVIDED.32003509A2.REM:STOP ALL WORK!PROVIDE PROTECTION AS PER DOB REQUINothing owed — awaiting certificate of correction
ECB03/08/2010(MISC)BC3304.4.3&27-1021MISC VIO.FAILURE TO PROVIDE REQUIRED LOT-LINE CONSTRUCTION FENCE (EXCAVATION)THERE IS AN EXCAVATION 9-11FT DEEP & NOFENCE INSTALLED CONTRARY TO DOB REQUIREMENTS (@ THE REAR OF PROPERTY)Nothing owed — awaiting certificate of correction
ECB03/08/2010WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS &/OR APPROVEDAMENDMENTS.THE SHEETING SHORING & BRACINGS NOT INSTALLED AS PER PLAN.THERE IS ALSO A WOOD BRIDGE & WOOD ROOF W/ABLUE TARP NOT ON PLANS.THENothing owed — awaiting certificate of correction