← Back
Primarily 2 family with 1 store or office
769 FULTON STREET
BROOKLYN · BIN 3059335
💬 Discuss this project
1930Year Built
3Stories
S2Building Class
R7AZoning
2,700 sfGross Floor Area
3Units
10 Open Violations ▸FDNY Report ↗
Primarily 2 family with 1 store or office · Owner of record: SUPER SLOTH, LLC · 1,602 sf lot · 1.69 FAR built · Flood zone X
Locations of Work
Structural
Floor 32p · 1 filing · 9 docs
Floor 22p · 1 filing · 9 docs
Floor 12p · 1 filing · 9 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/17/2023$3.4M—Private party → SUPER SLOTH, LLC$1,250/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JAJ ENGINEERING PLLC210/14/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ANTHONY BONSIGNORE RA203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KNS BUILDING REST. INCGeneral Contractor603/21/2026
LINVAL BROWNElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AVT ENGINEERING345210/14/2022
Building Lifecycle
All (43)Filed (2)Permit Issued (3)Signed Off (2)Violation (20)Special Inspection (16)
02/21/2023
Signed off — Alteration
PROVIDING TEMPORARY STRUCTURAL SHORING AND BRACING OF THE REAR 2 STORY AND CELLAR MASONRY FACADE AS PER PLAN FILED.
B00791750-S1
02/04/2023
Permit issued — General Construction
B00791750-S1-GC
01/25/2023
Permit issued — Structural
B00791750-S1-ST
01/24/2023
Signed off — Alteration
PROVIDING TEMPORARY STRUCTURAL SHORING AND BRACING OF THE REAR 2 STORY AND CELLAR MASONRY FACADE AS PER PLAN FILED.
B00791750-I1
10/14/2022
Filed — Alteration
PROVIDING TEMPORARY STRUCTURAL SHORING AND BRACING OF THE REAR 2 STORY AND CELLAR MASONRY FACADE AS PER PLAN FILED.
B00791750-S1
10/11/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
JOSEPH PASATURO
10/11/2022
Special inspection requirement — Masonry
JOSEPH PASATURO
10/11/2022
Special inspection requirement — Structural Cold-Formed Steel
JOSEPH PASATURO
10/11/2022
Special inspection requirement — Structural Steel - Details
JOSEPH PASATURO
10/11/2022
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
JOSEPH PASATURO
10/11/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
JOSEPH PASATURO
10/11/2022
Special inspection requirement — Structural Steel - High Strength Bolting
JOSEPH PASATURO
10/11/2022
Special inspection requirement — Structural Steel - Welding
JOSEPH PASATURO
10/11/2022
Special inspection requirement — Final
JOSEPH PASATURO
10/11/2022
Special inspection requirement — Energy Code Compliance Inspections
JOSEPH PASATURO
10/11/2022
Special inspection requirement — Fire-Resistance Rated Construction
JOSEPH PASATURO
10/11/2022
Special inspection requirement — Fenestration areas
JOSEPH PASATURO
10/11/2022
Special inspection requirement — Fenestration air leakage
JOSEPH PASATURO
10/11/2022
Special inspection requirement — Insulation placement and R values
JOSEPH PASATURO
10/11/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
JOSEPH PASATURO
10/11/2022
Special inspection requirement — Air barrier - visual inspection
JOSEPH PASATURO
09/07/2022
Permit issued — Structural
B00791750-I1-ST
08/11/2022
Filed — Alteration
PROVIDING TEMPORARY STRUCTURAL SHORING AND BRACING OF THE REAR 2 STORY AND CELLAR MASONRY FACADE AS PER PLAN FILED.
B00791750-I1
08/03/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/03/2022
Violation issued (ECB, closed)
Construction
08/03/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/15/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/06/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/06/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/31/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/31/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/19/2004
Violation issued (HPD, open)
A
08/19/2004
Violation issued (HPD, open)
A
08/19/2004
Violation issued (HPD, open)
B
08/19/2004
Violation issued (HPD, open)
B
12/11/2000
Violation issued (HPD, open)
C
12/11/2000
Violation issued (HPD, open)
C
12/11/2000
Violation issued (HPD, open)
C
12/11/2000
Violation issued (HPD, open)
C
12/11/2000
Violation issued (HPD, open)
B
12/11/2000
Violation issued (HPD, open)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offKNS BUILDING REST02/04/2023
DOB NOWStructuralPermit IssuedKNS BUILDING REST01/25/2023
DOB NOWStructuralSigned-offKNS BUILDING REST09/07/2022
BISOTISSUEDCAPITAL BUILDERS NYC INC04/01/2015
BISOTISSUEDCAPITAL BUILDERS NYC INC05/15/2014
BISMHISSUEDCAPITAL BUILDERS NYC INC10/10/2013
BISPLISSUEDVSP MECHANICAL INC08/14/2013
BISOTISSUEDCAPITAL BUILDERS NYC INC04/18/2013
BISOTISSUEDJABUS BUILDING CORP11/14/2011
BISMHISSUEDPETE MANNINO CONSTRUCTION08/10/2010
BISPLISSUEDMAINLAND PLG & HTG INC04/04/2002
BISOTISSUEDI.B.O. INC.05/16/2001
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
10/11/2022Structural Stability – Alterations of existing buildingsJOSEPH PASATUROspecial
10/11/2022MasonryJOSEPH PASATUROspecial
10/11/2022Structural Cold-Formed SteelJOSEPH PASATUROspecial
10/11/2022Structural Steel - DetailsJOSEPH PASATUROspecial
10/11/2022Exterior Insulation and Finish Systems (EIFS)JOSEPH PASATUROspecial
10/11/2022Fire-Resistant Penetrations and JointsJOSEPH PASATUROspecial
10/11/2022Structural Steel - High Strength BoltingJOSEPH PASATUROspecial
10/11/2022Structural Steel - WeldingJOSEPH PASATUROspecial
10/11/2022FinalJOSEPH PASATUROprogress
10/11/2022Energy Code Compliance InspectionsJOSEPH PASATUROprogress
10/11/2022Fire-Resistance Rated ConstructionJOSEPH PASATUROprogress
10/11/2022Fenestration areasJOSEPH PASATUROenergy_progress
10/11/2022Fenestration air leakageJOSEPH PASATUROenergy_progress
10/11/2022Insulation placement and R valuesJOSEPH PASATUROenergy_progress
10/11/2022Fenestration and door U-factor and product ratingsJOSEPH PASATUROenergy_progress
10/11/2022Air barrier - visual inspectionJOSEPH PASATUROenergy_progress
▾Documents — 76 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/28/2026B00791750-I1Request digital key ↗
08/28/2026B00791750-S1Request digital key ↗
▸Applications & Permits11
▸BISPLAN / WORK APPROVAL APPLICATION8
10/27/2015320751879Open ↗
09/24/2013320873630Open ↗
08/29/2013320561762Open ↗
Showing 3 of 8 on file for this type
▸BISWORK PERMIT APPLICATION3
10/24/2013320873630Open ↗
10/24/2013320873630Open ↗
08/11/2010320181799Open ↗
▸Seals & Professional Certifications19
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION11
11/13/2015320181799Open ↗
10/29/2015320181799Open ↗
06/12/2014320873630Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026B00791750-S1Open ↗
08/13/2026B00791750-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/25/2026B00791750-S1Open ↗
08/25/2026B00791750-S1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/25/2026B00791750-S1Open ↗
08/25/2026B00791750-S1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
07/06/2010320181799Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
07/06/2010320181799Open ↗
▸Trade Schedules & Equipment10
▸BISEQUIPMENT USE PERMITS4
11/13/2015320181799Open ↗
11/13/2015320181799Open ↗
11/13/2015320181799Open ↗
Showing 3 of 4 on file for this type
▸BISEQUIPMENT USE APPLICATION/PERMIT4
11/13/2015320181799Open ↗
06/12/2014320873630Open ↗
09/24/2013320873630Open ↗
Showing 3 of 4 on file for this type
▸BISSCHEDULE B - PLUMBING2
11/28/2012320561762Open ↗
10/18/2012320561762Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
07/06/2010320181799Open ↗
▸Environmental & Asbestos5
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)2
10/18/2012320561762Open ↗
10/18/2012320561762Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
09/24/2013320873630Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
07/06/2010320181799Open ↗
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
08/13/2026B00791750-S1Open ↗
▸Energy Compliance6
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS4
06/12/2014320873630Open ↗
10/24/2013320873630Open ↗
09/24/2013320873630Open ↗
Showing 3 of 4 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS1
06/12/2014320873630Open ↗
▸BISTECHNICAL REPORT: ENERGY1
11/15/2011320329603Open ↗
▸Approvals, Objections & Sign-offs8
▸BISADMINISTRATIVE OBJECTIONS4
09/24/2013320873630Open ↗
11/30/2012320751879Open ↗
07/11/2011320329603Open ↗
Showing 3 of 4 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST4
11/13/2015320181799Open ↗
10/29/2015320181799Open ↗
06/12/2014320873630Open ↗
Showing 3 of 4 on file for this type
▸Cost, Insurance & Ownership9
▸BISCOST AFFIDAVIT9
11/13/2015320181799Open ↗
10/29/2015320181799Open ↗
06/12/2014320873630Open ↗
Showing 3 of 9 on file for this type
▸Filing & Intake Forms5
▸BISEFILING COVER SHEET5
09/24/2013320873630Open ↗
11/30/2012320751879Open ↗
10/18/2012320561762Open ↗
Showing 3 of 5 on file for this type