← Back
Primarily 5-6 family with 1 store or office
28 THROOP AVENUE
BROOKLYN · BIN 3061314
💬 Discuss this project
1931Year Built
3Stories
S5Building Class
R6AZoning
4,500 sfGross Floor Area
7Units
Rent Stabilized6 Open Violations ▸FDNY Report ↗
Primarily 5-6 family with 1 store or office · Owner of record: MOORE MANAGMENT L.L.C · 2,340 sf lot · 1.92 FAR built · Flood zone X500
Locations of Work
ArchitectureMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction4p · 2 filings · 16 docs
Floor 1Under Construction6p · 1 filing · 9 docs
CellarUnder Construction2p · 1 filing · 9 docs
1 job · most recent 08/03/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/03/2026Permit IssuedMJH CONSTRUCTION CORPHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MXZ-4C36NAHZ2 36,000 BTU · Heat Pump Outdoor ×4
PKFY-P24NKMU-E2 24,000 BTU · Vrf Indoor ×2
PKFY-P24NKMU-E 24,000 BTU · Vrf Indoor ×1
Daikin FTX36NVJU 36,000 BTU · Fan Coil Indoor ×2
Ventilation
Captiveaire A1-G10D 2,500 CFM · Makeup Air ×1
NCA24FA 3,750 CFM · Exhaust Fan ×1
— NCA18FA 3,100 BTU · Exhaust Fan ×1
1 job · most recent 08/03/2026
Gas Water/Sanitary
FiledStatusContractorScope
08/03/2026Permit IssuedJETWORK SERVICES LLCGas, Water/Sanitary
2 jobs · most recent 04/02/2025
General Wiring
FiledStatusContractorScope
04/02/2025Permit IssuedACCURATE ELEC'L CORP.General Wiring
04/26/2021Permit IssuedRICHARD NEU—
Building Lifecycle
All (56)Filed (5)Permit Issued (5)Signed Off (3)Violation (27)Special Inspection (16)
08/31/2026
Permit issued — Mechanical Systems
B01434916-S1-MS
08/14/2026
Permit issued — Plumbing
B01434916-I1-PL
08/03/2026
Filed — Alteration
TO INSTALL NEW MINI SPLIT HVAC UNITS, EXHAUST FAN AND MAKE UP AIR KITCHEN HOOD, DUCT WORK AND REPLACE EXISTING EXHAUST FAN WITH NEW.
B01434916-S1
08/03/2026
Filed — Alteration
TO INSTALL NEW MINI SPLIT HVAC UNITS, EXHAUST FAN AND MAKE UP AIR KITCHEN HOOD, DUCT WORK AND REPLACE EXISTING EXHAUST FAN WITH NEW.
B01434916-I1
07/22/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
PETER NYIAM
07/22/2026
Special inspection requirement — Tenant Protection Plan Compliance
PETER NYIAM
07/22/2026
Special inspection requirement — Energy Code Compliance Inspections
FRANKLYN ESTRELLA
07/22/2026
Special inspection requirement — HVAC-R and service water heating equipment
FRANKLYN ESTRELLA
07/22/2026
Special inspection requirement — HVAC-R and service water heating system controls
FRANKLYN ESTRELLA
07/22/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
FRANKLYN ESTRELLA
08/27/2025
Violation issued (HPD, closed)
A
08/27/2025
Violation issued (HPD, closed)
A
08/27/2025
Violation issued (HPD, closed)
A
08/27/2025
Violation issued (HPD, closed)
A
11/26/2021
Signed off — Alteration
EXTERIOR RENOVATION ON THE FACADE ONLY. NO INTERIOR WORK. NO CHANGE OF USE ,OCCUPANCY OR EGRESS, AND NO CHANGE TO THE EXISTING GROSS OR ZONING AREA.
B00486448-I1
11/24/2021
Violation issued (ECB, closed)
Construction
11/09/2021
Signed off — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVE LOAD 300 PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER # 33 OF THE 2014 CODE. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
B00510041-I1
11/09/2021
Signed off — Alteration
ALTERATION TYPE 3 - CONSTRUCTION EQUIPMENT - SCAFFOLDING INSTALLATION OF PIPE SCAFFOLD AS PER PLANS. PIPE SCAFFOLD SHALL COMPLY WITHCHAPTER 33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00522883-I1
06/23/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/26/2021
Permit issued — Supported Scaffold
B00522883-I1-SF
05/25/2021
Filed — Alteration
ALTERATION TYPE 3 - CONSTRUCTION EQUIPMENT - SCAFFOLDING INSTALLATION OF PIPE SCAFFOLD AS PER PLANS. PIPE SCAFFOLD SHALL COMPLY WITHCHAPTER 33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00522883-I1
05/15/2021
Special inspection requirement — Final
RAFI HAMID
04/30/2021
Permit issued — Sidewalk Shed
B00510041-I1-SH
04/29/2021
Filed — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVE LOAD 300 PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER # 33 OF THE 2014 CODE. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
B00510041-I1
04/27/2021
Permit issued — General Construction
B00486448-I1-GC
04/13/2021
Violation issued (HPD, closed)
A
03/23/2021
Filed — Alteration
EXTERIOR RENOVATION ON THE FACADE ONLY. NO INTERIOR WORK. NO CHANGE OF USE ,OCCUPANCY OR EGRESS, AND NO CHANGE TO THE EXISTING GROSS OR ZONING AREA.
B00486448-I1
03/23/2021
Violation issued (ECB, closed)
Construction
03/23/2021
Special inspection requirement — Fenestration and door U-factor and product ratings
Thomas Barry
03/23/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Thomas Barry
03/23/2021
Special inspection requirement — Fenestration air leakage
Thomas Barry
03/23/2021
Special inspection requirement — Final
Thomas Barry
03/23/2021
Special inspection requirement — Energy Code Compliance Inspections
Thomas Barry
03/23/2021
Special inspection requirement — Fire-Resistance Rated Construction
Thomas Barry
03/23/2021
Special inspection requirement — Air barrier - visual inspection
Thomas Barry
03/23/2021
Special inspection requirement — Interior lighting power
Thomas Barry
03/23/2021
Special inspection requirement — Fenestration areas
Thomas Barry
01/11/2021
Violation issued (ECB, closed)
Construction
10/26/2020
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
10/06/2020
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
10/06/2020
Violation issued (ECB, closed)
Construction
05/20/2010
Violation issued (ECB, closed)
Construction
05/18/2005
Violation issued (HPD, closed)
A
06/11/2001
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/11/2001
Violation issued (ECB, closed)
Construction
05/02/2001
Violation issued (HPD, closed)
A
03/14/2001
Violation issued (ECB, closed)
Construction
03/14/2001
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
10/27/1998
Violation issued (FDNY_ORDER, closed)
10/27/1998
Violation issued (ECB, closed)
Construction
10/27/1998
Violation issued (ECB, closed)
Construction
02/12/1998
Violation issued (ECB, closed)
Construction
02/12/1998
Violation issued (DOB, closed)
VW*-VIOLATION - WORK W/O PERMIT DISMISSED
07/15/1997
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/09/1997
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/13/1989
Violation issued (ECB, closed)
Construction
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
TOPLINE NYC CONTRACTING507/08/2026
TRUST MANAGEMENT303/22/2026
MOORE MANAGMENT L.L.C1103/22/2026
MOORE MANAGMENT L L C 28103/22/2026
MAYER REALTY CORP303/22/2026
OWNER OF 28 THROOP AVE103/22/2026
MAYOR REALTY CORP103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PETER NYIAM208/03/2026
SYED ENGINEERING, P.C.205/25/2021
THOMAS BARRY ARCHITECT103/23/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ADVANCED BUILDERS SERVICES203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TOPLINE NYC CONTRACTINGGeneral Contractor407/08/2026
SAT CONSTRUCTION SERVICESGeneral Contractor303/21/2026
LELIS, ARILSONElectrical103/21/2026
NEU, RICHARDElectrical103/21/2026
RAMDEEN, BALDATHElectrical103/21/2026
RAMSARRAN, RAMESHElectrical103/21/2026
REDROVAN ELIASElectrical103/21/2026
RICHARD NEUElectrical103/21/2026
SERGIO GIANNACHIElectrical103/21/2026
WALSH LAWRENCEElectrical103/21/2026
MJH CONSTRUCTION CORPGeneral Contractor109/01/2026
BENJAMIN DREBINElectrical103/21/2026
JETWORK SERVICES LLCPlumbing108/16/2026
HESCOTT, CARDINALElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PIBIEN ENGINEERS9656208/03/2026
OPERA STUDIO ARCHITECTURE5970103/23/2021
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedMJH CONSTRUCTION CORP08/31/2026
DOB NOWPlumbingPermit IssuedJETWORK SERVICES LLC08/14/2026
DOB NOWSupported ScaffoldSigned-offTOPLINE NYC CONTRACTING05/26/2021
DOB NOWSidewalk ShedSigned-offTOPLINE NYC CONTRACTING04/30/2021
DOB NOWGeneral ConstructionSigned-offSAT CONSTRUCTION SERVICES04/27/2021
BISFPISSUEDMETFLOW FIRE CONTROL LLC06/14/2019
BISPLISSUEDAP PLUMBING & HVAC LLC07/02/1998
BISOTISSUEDHONHURAS CONSTR02/25/1998
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
07/22/2026Fire-Resistant Penetrations and JointsPETER NYIAMspecial
07/22/2026Tenant Protection Plan CompliancePETER NYIAMspecial
07/22/2026Energy Code Compliance InspectionsFRANKLYN ESTRELLAprogress
07/22/2026HVAC-R and service water heating equipmentFRANKLYN ESTRELLAenergy_progress
07/22/2026HVAC-R and service water heating system controlsFRANKLYN ESTRELLAenergy_progress
07/22/2026HVAC-R and service water piping design and insulationFRANKLYN ESTRELLAenergy_progress
05/15/2021FinalRAFI HAMIDprogress
03/23/2021Fenestration and door U-factor and product ratingsThomas Barryenergy_progress
03/23/2021Fire-Resistant Penetrations and JointsThomas Barryspecial
03/23/2021Fenestration air leakageThomas Barryenergy_progress
03/23/2021FinalThomas Barryprogress
03/23/2021Energy Code Compliance InspectionsThomas Barryprogress
03/23/2021Fire-Resistance Rated ConstructionThomas Barryprogress
03/23/2021Air barrier - visual inspectionThomas Barryenergy_progress
03/23/2021Interior lighting powerThomas Barryenergy_progress
03/23/2021Fenestration areasThomas Barryenergy_progress
▾Documents — 36 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
09/01/2026B00486448-I1Request digital key ↗
09/01/2026B00510041-I1Request digital key ↗
09/01/2026B00522883-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits4
▸BISWORK PERMIT APPLICATION2
06/17/2019321960534Open ↗
06/17/2019321960534Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION2
06/04/2019321940165Open ↗
06/04/2019321960534Open ↗
▸Seals & Professional Certifications16
▸DOB NOWDPL-1: Design Professional Seal & Signature5
09/01/2026B00486448-I1Open ↗
09/01/2026B00510041-I1Open ↗
09/01/2026B00522883-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
08/28/2026B01434916-I1Open ↗
08/28/2026B01434916-I1Open ↗
08/27/2026B00522883-I1Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
06/17/2019321960534Open ↗
06/04/2019321960534Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/28/2026B01434916-I1Open ↗
08/23/2026B00486448-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
06/04/2019321960534Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
06/04/2019321960534Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
06/04/2019321940165Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
06/04/2019321960534Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
09/01/2026B00486448-I1Open ↗
08/16/2026B01434916-I1Open ↗
08/16/2026B01434916-S1Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
06/04/2019321960534Open ↗
06/04/2019321960534Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
09/01/2026B00486448-I1Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
06/04/2019321960534Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET2
06/04/2019321940165Open ↗
06/04/2019321960534Open ↗