← Back
Predominantly retail with other uses
487 DRIGGS AVENUE
BROOKLYN · BIN 3061706
💬 Discuss this project
1925Year Built
2Stories
K4Building Class
M1-2/R6AZoning
5,000 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Predominantly retail with other uses · Owner of record: BREY REALTY LLC · 2,500 sf lot · 2 FAR built · Flood zone X500
Locations of Work
Architecture
Floor 12p · 1 filing · 13 docs
2 jobs · most recent 07/12/2022
FiledStatusContractorScope
07/12/2022Permit IssuedTRIPLE T ELECTRIC INC1 meters, 1 new_meters
02/04/2022CompleteRAINBOW ELECTRIC CO., INC—
Building Lifecycle
All (30)Filed (3)Permit Issued (3)Signed Off (1)Violation (8)Objection (6)Special Inspection (9)
06/23/2022
Signed off — Alteration
B00670997-I1
02/04/2022
Permit issued — Sign
B00670997-I1-SG
02/03/2022
Filed — Alteration
B00670997-I1
01/11/2022
Permit issued — General Construction
B00623763-I1-GC
01/11/2022
Permit issued — Construction Fence
B00645000-I1-FN
12/22/2021
Filed — Alteration
B00645000-I1
12/13/2021
Special inspection requirement — Insulation placement and R values
ANASTASIOS GIANNOPOULOS
12/09/2021
Special inspection requirement — Masonry
ANASTASIOS GIANNOPOULOS
12/09/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
ANASTASIOS GIANNOPOULOS
12/09/2021
Special inspection requirement — Air barrier - visual inspection
ANASTASIOS GIANNOPOULOS
11/29/2021
Objection raised — Scope
11/29/2021
Objection resolved — Addressed
11/29/2021
Objection raised — Inspections
11/29/2021
Objection resolved — Addressed
11/29/2021
Objection raised — Fire_Protection
11/29/2021
Objection resolved — Addressed
11/23/2021
Filed — Alteration
Replace existing storefront and front door with new. Partial demolition No change to use, egress or occupancy.
B00623763-I1
11/22/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANASTASIOS GIANNOPOULOS
11/02/2021
Special inspection requirement — Fenestration and door U-factor and product ratings
ANASTASIOS GIANNOPOULOS
11/02/2021
Special inspection requirement — Fenestration air leakage
ANASTASIOS GIANNOPOULOS
11/02/2021
Special inspection requirement — Fenestration areas
ANASTASIOS GIANNOPOULOS
11/02/2021
Special inspection requirement — Energy Code Compliance Inspections
ANASTASIOS GIANNOPOULOS
02/22/2011
Violation issued (ECB, closed)
Unknown
02/09/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/08/2011
Violation issued (ECB, closed)
Unknown
11/16/2010
Violation issued (ECB, closed)
Construction
07/20/2010
Violation issued (ECB, closed)
Construction
07/20/2010
Violation issued (ECB, closed)
Construction
07/20/2010
Violation issued (ECB, closed)
Construction
02/07/2005
Violation issued (ECB, closed)
Construction
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MOHAMMAD AHEAD, PE102/03/2022
A. GIANNOPOULOS ARCHITECTS PLLC.212/22/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
LOUIS STRIAR203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JOANNE'S CONSTRUCTION COGeneral Contractor403/21/2026
BLATT, SElectrical203/21/2026
DE LA CRUZ, LEWISElectrical203/21/2026
SIGNSTAR NYCScaffold107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A. GIANNOPOULOS ARCHITECT2196111/23/2021
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSignSigned-offSIGNSTAR NYC02/04/2022
DOB NOWGeneral ConstructionPermit IssuedJOANNE'S CONSTRUCTION CO01/11/2022
DOB NOWConstruction FencePermit IssuedJOANNE'S CONSTRUCTION CO01/11/2022
BISPLISSUEDA. M. PLUMBING COMPANY08/04/2020
BISPLISSUEDA. M. PLUMBING COMPANY02/19/2003
BISOTISSUEDNEXOR INTERIORS CORP01/09/2003
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
12/13/2021Insulation placement and R valuesANASTASIOS GIANNOPOULOSenergy_progress
12/09/2021MasonryANASTASIOS GIANNOPOULOSspecial
12/09/2021Structural Stability – Alterations of existing buildingsANASTASIOS GIANNOPOULOSspecial
12/09/2021Air barrier - visual inspectionANASTASIOS GIANNOPOULOSenergy_progress
11/22/2021Fire-Resistant Penetrations and JointsANASTASIOS GIANNOPOULOSspecial
11/02/2021Fenestration and door U-factor and product ratingsANASTASIOS GIANNOPOULOSenergy_progress
11/02/2021Fenestration air leakageANASTASIOS GIANNOPOULOSenergy_progress
11/02/2021Fenestration areasANASTASIOS GIANNOPOULOSenergy_progress
11/02/2021Energy Code Compliance InspectionsANASTASIOS GIANNOPOULOSprogress
▾Documents — 56 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/31/2026B00645000-I1Request digital key ↗
08/31/2026B00670997-I1Request digital key ↗
08/14/2026B00623763-I1Request digital key ↗
▸Applications & Permits9
▸BISPLAN / WORK APPROVAL APPLICATION6
12/29/2020301381341Open ↗
11/18/2020320218849Open ↗
11/13/2020320218849Open ↗
Showing 3 of 6 on file for this type
▸BISWORK PERMIT APPLICATION3
09/03/2020301381341Open ↗
12/07/2010320246195Open ↗
10/19/2010320218849Open ↗
▸Seals & Professional Certifications19
▸DOB NOWProgress Inspector Seal & Signature6
08/23/2026B00623763-I1Open ↗
08/23/2026B00623763-I1Open ↗
08/23/2026B00623763-I1Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
09/20/2011320246195Open ↗
12/07/2010320246195Open ↗
09/24/2010320218849Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/31/2026B00623763-I1Open ↗
08/31/2026B00645000-I1Open ↗
08/31/2026B00670997-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature3
08/23/2026B00623763-I1Open ↗
08/23/2026B00623763-I1Open ↗
08/23/2026B00623763-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
12/07/2010320246195Open ↗
09/24/2010320218849Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
12/07/2010320246195Open ↗
09/24/2010320218849Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING2
12/29/2020301381341Open ↗
10/15/2020301381341Open ↗
▸Safety & Tenant Protection4
▸DOB NOWHPD-1: Anti-Harassment Area Checklist3
08/13/2026B00623763-I1Open ↗
08/13/2026B00645000-I1Open ↗
08/13/2026B00670997-I1Open ↗
▸BISANTI-HARASSMENT CHECKLIST1
09/27/2010320218849Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/31/2026B00670997-I1Open ↗
08/14/2026B00623763-I1Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
12/07/2010320246195Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
09/24/2010320218849Open ↗
▸Inspections & Test Reports4
▸BISTECHNICAL REPORT: RESPONSIBILITY2
12/04/2020320218849Open ↗
12/04/2020320218849Open ↗
▸BISSTRUCTURAL STABILITY - EXISTING BUILDINGS1
12/04/2020320218849Open ↗
▸BIS* FINAL INSPECTION DIRECTIVE 14 OF 19751
04/23/2021301381341Open ↗
▸Approvals, Objections & Sign-offs6
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
04/23/2021301381341Open ↗
12/04/2020320218849Open ↗
09/20/2011320246195Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
12/07/2010320246195Open ↗
09/24/2010320218849Open ↗
▸BISFINAL1
12/04/2020320218849Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT1
09/24/2010320218849Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
12/04/2020320218849Open ↗
▸Filing & Intake Forms3
▸BISEFILING COVER SHEET2
12/07/2010320246195Open ↗
09/24/2010320218849Open ↗
▸BISBOROUGH INTAKE FORM1
09/03/2020301381341Open ↗