← Back
Three families
111 CALYER STREET
BROOKLYN · BIN 3065087
💬 Discuss this project
1901Year Built
3Stories
C0Building Class
R6BZoning
2,244 sfGross Floor Area
3Units
Rent Stabilized20 Open Violations ▸
Three families · 1,800 sf lot · 1.25 FAR built · Flood zone X500
Locations of Work
Architecture
Penthouse1p · 1 filing · 5 docs
Floor 41p · 1 filing · 5 docs
Floor 3
Floor 2
Floor 1
Cellar2p · 1 filing · 5 docs
Nothing on file for this building.
Building Lifecycle
All (53)Filed (1)Violation (34)Objection (1)Special Inspection (17)
08/20/2026
Objection raised — Other
07/21/2026
Filed — Alteration CO
HORIZONTAL AND VERTICAL ENLARGEMENT TO THE EXISTING 3-STORY BUILDING TO 3-STORY WITH CELLAR AND PENTHOUSE SINGLE DWELLING UNIT BUILDING WITH NEW LAYOUT AS PER PLAN.
B01428761-I1
07/13/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
07/13/2026
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
07/13/2026
Special inspection requirement — Electrical motors and elevators
07/10/2026
Special inspection requirement — Energy Code Compliance Inspections
07/10/2026
Special inspection requirement — Fire-Resistance Rated Construction
07/10/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
07/10/2026
Special inspection requirement — Fenestration areas
07/10/2026
Special inspection requirement — Air barrier - visual inspection
07/10/2026
Special inspection requirement — Insulation placement and R values
07/10/2026
Special inspection requirement — Lighting controls
07/10/2026
Special inspection requirement — Interior lighting power
07/10/2026
Special inspection requirement — Exterior lighting power
07/10/2026
Special inspection requirement — Maintenance information
07/10/2026
Special inspection requirement — Lighting in dwelling units
07/10/2026
Special inspection requirement — Metering
07/10/2026
Special inspection requirement — Fenestration air leakage
07/10/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
05/04/2026
Violation issued (HPD, open)
A
11/20/2025
Violation issued (HPD, open)
I
06/09/2025
Violation issued (HPD, open)
A
11/27/2024
Violation issued (HPD, closed)
I
04/09/2024
Violation issued (HPD, open)
A
11/21/2023
Violation issued (HPD, closed)
I
03/21/2023
Violation issued (HPD, open)
A
11/10/2022
Violation issued (HPD, closed)
I
02/23/2022
Violation issued (HPD, open)
A
02/23/2022
Violation issued (HPD, closed)
I
04/07/2021
Violation issued (HPD, closed)
I
04/07/2021
Violation issued (HPD, open)
A
10/29/2019
Violation issued (HPD, closed)
I
10/16/2018
Violation issued (HPD, closed)
I
11/20/2017
Violation issued (HPD, closed)
I
11/04/2016
Violation issued (HPD, closed)
I
10/07/2015
Violation issued (HPD, closed)
I
02/18/2015
Violation issued (HPD, closed)
I
07/18/1996
Violation issued (ECB, closed)
Construction
07/16/1996
Violation issued (ECB, closed)
Construction
04/26/1991
Violation issued (ECB, closed)
Construction
07/08/1988
Violation issued (HPD, open)
A
07/08/1988
Violation issued (HPD, open)
A
07/08/1988
Violation issued (HPD, open)
A
07/08/1988
Violation issued (HPD, open)
B
07/08/1988
Violation issued (HPD, open)
B
07/08/1988
Violation issued (HPD, open)
A
07/08/1988
Violation issued (HPD, open)
B
07/08/1988
Violation issued (HPD, open)
C
07/08/1988
Violation issued (HPD, open)
A
07/08/1988
Violation issued (HPD, open)
A
07/08/1988
Violation issued (HPD, open)
B
07/08/1988
Violation issued (HPD, open)
B
07/08/1988
Violation issued (HPD, open)
C
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
TO THE OWNER OF THE PREMI103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
THOMAS C. TUNG, P.E.107/21/2026
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 17
DateRequirementInspectorRole
07/13/2026Structural Stability – Alterations of existing buildings—special
07/13/2026Exterior Insulation and Finish Systems (EIFS)—special
07/13/2026Electrical motors and elevators—energy_progress
07/10/2026Energy Code Compliance Inspections—progress
07/10/2026Fire-Resistance Rated Construction—progress
07/10/2026Fenestration and door U-factor and product ratings—energy_progress
07/10/2026Fenestration areas—energy_progress
07/10/2026Air barrier - visual inspection—energy_progress
07/10/2026Insulation placement and R values—energy_progress
07/10/2026Lighting controls—energy_progress
07/10/2026Interior lighting power—energy_progress
07/10/2026Exterior lighting power—energy_progress
07/10/2026Maintenance information—energy_progress
07/10/2026Lighting in dwelling units—energy_progress
07/10/2026Metering—energy_progress
07/10/2026Fenestration air leakage—energy_progress
07/10/2026Fire-Resistant Penetrations and Joints—special
▾Documents — 5 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/16/2026B01428761-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/16/2026B01428761-I1Open ↗
▸Seals & Professional Certifications1
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/16/2026B01428761-I1Open ↗
▸Other Documents2
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/16/2026B01428761-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/16/2026B01428761-I1Open ↗