DOB03/13/2026BOROUGH COMMISSIONER HAS ORDERED ALL WORK STOPPED UNDER PERMIT# B01022067-I1 ON 11/18/25. CONTRACTOR WITHDRAWAL
ECB09/10/2025FAILURE TO PROMPTLY NOTIFY THE DEPARTMENT OF AN ACCIDENT,INCIDENT OR DAMAGED TO ADJOINING PROPERTY AT CONSTRUCTION/DEMOLITION SITE.GC FAILEDTO NOTIFY THE DEPARTMENT OF AN INCIDENT THAT OCCURRED ON 9/6/25.AS PER$5K due
DOB09/10/2025EMERGENCY WORK ORDER.BLDG SFFRD A FIRE ON FEB 2024 W/CHARRNG OF STRCTL MEMBRS ROOF&WNDWS OUT,FIRE WATER&SMOKE DMG THROUGHOUT.BLDG SFFRD AN ADDTNL PARTIAL CLLPSE ON 9/8/25& IS IN DANGER OF FRTHR CLLPSE.COMPLY WITH COMMISSIONER'S ORDER:DOB VIOLATION:090825FEU30101AK (CONTROL 3341636) IMMEDIATELY
ECB09/10/2025WORK AFTER HOURS WITHOUT A VARIANCE PERMIT CONTRARY TO 28-105.12.5.AFTER HOUR CONSTRUCTION TOOK PLACE ON SATURDAY SEPTEMBER 6TH WITH NO AFTER HOUR VARIANCE PERMIT FILED IN THE DOB SYSTEM #44991 WAS SUBMITTED ON$3K due
ECB09/10/2025CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES PER CODE.CONSTRUCTION SUPERINTENDENT FAILED TO PROMPTLY NOTIFY THE DEPARTMENT OF AN INCIDENT THAT OCCURRED ON 9/6/2025 WHERE A WORKER WAS INJURED DURING DEM$25K due
DOB09/08/2025EMERGENCY WORK ORDER.BLDG SFFRD A FIRE ON FEB 2024 W/CHARRNG OF STRCTRL MEMBRS ROOF&WNDWS OUT,FIRE WATER&SMOKE DMG THROUGHOUT.BLDG SFFRD AN ADDTNL PARTIAL CLLPSE ON 9/8/25&IS IN DANGER OF FRTHR CLLPSE OWNR TO ENGAGE NYSPE W/O DISCIPLINARY ACTION&ENDRSD CNTRCTR TO IMMED DEMO THE BLDG UNDR EMRGNCY WRK.NYSPE TO SBMT MEANS&METHDS TO FEU
ECB09/08/2025UPON INSPECTION, FULL DEMOLITION UNDERGOING OPERATION AND CONTRACTOR FAILED TO PROVIDE OVERHEAD PROTECTION AT ADJACENT PROPERTY ON EXPOSURE 4 (169 MESEROLE AVENUE) AND TO MAINTAIN CONSTRUCTION FENCE. THIS CREAT$10K due
ECB09/07/2025AT THE TIME OF INSPECTION, INACTIVE JOBSITE. I OBSERVED THAT THE CONSTRUCTION FENCE PANELS AT EXPOSURE ALL EXPOSURE NOT PROPERLY MAINTAINED PURSUANT TO SUBSECTION ACCORDING TO BC 3307.7. FENCE PANELS IN INADEQ$1K due
ECB09/07/2025INACTIVE JOBSITE, I OBSERVED CONSTRUCTION FENCE INSTALLED AT ALL EXPOSURE IN ADEQUATE CONDITION (PANELS NOT MAINTAINED NOT FULLY ENCLOSED WITH COLLAPSE PANEL). AFTER REVIEW OF BIS & DOB RECORDS FENCE PERMIT EXP$1K due
ECB09/06/2025FAILURE TO PROMPTLY NOTIFY THE DEPARTMENT OF AN ACCIDENT/INCIDENT OF DAMAGE TO ADJOINING PROPERTY AT CONSTRUCTION/DEMOLITION SITE.OWNER OF PROPERTY FAILED TO NOTIFY THE DEPARTMENT OF AN INCIDENT THAT OCCURRED O$5K due
ECB09/06/2025WORK AFTER HOURS WITHOUT A VARIANCE PERMIT CONTRARY TO 28-105.12.5.AFTER HOUR CONSTRUCTION TOOK PLACE ON SATURDAY SEPTEMBER 6TH WITH NO AFTER HOUR VARIANCE PERMIT FILED IN THE DOB SYSTEM INCIDENT#44991 WAS SUBM$2K due
ECB07/01/2025OBSERVED CONSTRUCTION FENCE @ EXPOSURE 1 & 2. THE HAS DAMAGES & OPENINGS THROUGHOUT & IS COVERED EXTENSIVELY WITH ADVERTISEMENT POSTERS. VIEWING PANELS MISSING PLEXIGLASS COVERINGS TO GO OVER WINDOW OPENINGS ON$5K due
ECB04/10/2025RESPONDING A COMPLAINT OBSERVED: SIDEWALK SHED INSTALLED AT EXPO# 1-2 WITH ELECTRICAL WORK. UPON REVIEW DEPARTMENT RECORD IT APPEAR NO ELECTRICAL PERMIT FOR UNDERSIDE LIGHTING ON SIDEWALK SHED, CREATING AN UNSA$800 due
ECB04/10/2025RESPONDING A COMPLAINT OBSERVED: SIDEWALK SHED INSTALLED AT EXPO# 1-2. NO UNDERSIDE LIGHTING INOPERABLE LIGHT BULBS, FAILURE TO MAINTAIN AS PER CODE 3307.6.4.8 BECOME AN UNSAFE AND HAZARDOUS CONDITION FOR PEDES$2K due
ECB03/31/2025AT TIME OF INSPECTION OBSERVED SWS INSTALLED AT EXP1&2. HORIZONTAL MEMBERS ONLY HAD A HEIGHT OF 7FT FROM STREET LEVEL AS PER BC 3307.6.4.7 8FT IS REQUIRED. VERTICAL POST NOT 18" FROM CURB AS PER BC 3307.6.4.4(4$10K due
DOB02/13/2024V-DOB VIOLATION - ACTIVE
DOB02/12/2024OBSRVD BLDG IN A STATE OF DISREPAIR W/FIRE DAMAGE THROUGHOUT MINOR CHARRNG OF STRCTRL MEMBERS, ROOF AND WINDOWS OUT.SGNS OF WATER DAMAGE THROUGHOUT.REAR PERGOLA SEVERELY DETERIORARD.BLDG IS UNGUARDED.OWNR TO ENGAGE A NYSPE&ENDORSD CNTRCTR TO EVAL THE ENT BLDG&DEVELOP PLANS TO RPAIR OR DEMO.FILE FOR PRMTS BY 3/15/24
DOB02/12/2024SEAL ALL ACCESSIBLE OPENINGS TO BUILDINGS TO SAFEGUARD THE PUBLIC AND PROPERTY
DOB02/10/2024PREMISES RENDERED NON COMPLIANT DUE TO FIRE. NOTED: THERE IS EXTENSIVE FIRE AND FIREFIGHTING DAMAGE WITH WINDOWS OUT, BILCO DOOR REMOVED, ROOF OPEN TO THE ELEMENTS WITH EXCESSIVE CLUTTER REMAINING.