← Back
Five to six families
499 GRAHAM AVENUE
BROOKLYN · BIN 3067830
💬 Discuss this project
1928Year Built
3Stories
C2Building Class
R6BZoning
4,125 sfGross Floor Area
6Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Five to six families · Owner of record: 499 GRAHAM AVE, LLC · 2,219 sf lot · 1.86 FAR built · Flood zone X500
Locations of Work
ArchitectureMechanicalPlumbing
Permit Issued — active, not yet Signed-off
Floor 3Under Construction12p · 2 filings · 20 docs
Floor 2Under Construction11p · 2 filings · 20 docs
Floor 1Under Construction12p · 2 filings · 20 docs
CellarUnder Construction12p · 2 filings · 20 docs
1 job · most recent 07/15/2026
Ventilation Systems
FiledStatusContractorScope
07/15/2026Permit IssuedBRIDGE ZALE CONSTRUCT CORVentilation Systems
1 job · most recent 07/15/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
07/15/2026Permit IssuedNEW YORK PARK PLBG&HTG COGas, Storm, Water/Sanitary
1 job · most recent 05/01/2026
General Wiring
FiledStatusContractorScope
05/01/2026Permit IssuedJOSEPH WEINSTEIN ELECTRICGeneral Wiring
1 job · most recent 07/15/2026
Tenant Protection Plan 72 Hour
FiledStatusContractorScope
07/15/2026Permit IssuedNEW YORK PARK PLBG&HTG COTenant Protection Plan 72 Hour
Building Lifecycle
All (104)Filed (6)Permit Issued (5)Violation (15)Inspection (6)Objection (54)Special Inspection (18)
08/19/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
08/13/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/10/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
07/15/2026
Filed — Alteration
RELOCATION AND REPLACEMENT OF THE BOILER AS PER PLANS FILED HEREWITH, NO CHANGE IN USE, EGRESS AND OCCUPANCY.
B01205259-P1
07/09/2026
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
07/08/2026
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
06/30/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
06/24/2026
Permit issued — Plumbing
B01205259-S2-PL
06/04/2026
Permit issued — General Construction
B01344763-I1-GC
04/17/2026
Objection resolved — Resolved
04/17/2026
Objection resolved — Resolved
04/17/2026
Objection resolved — Resolved
04/17/2026
Objection resolved — Resolved
04/17/2026
Objection resolved — Resolved
04/17/2026
Objection resolved — Resolved
04/17/2026
Objection resolved — Resolved
04/17/2026
Special inspection requirement — Air barrier - visual inspection
CARL HAMANN
04/17/2026
Special inspection requirement — Permanent certificate
CARL HAMANN
04/17/2026
Special inspection requirement — Interior lighting power
CARL HAMANN
03/13/2026
Objection resolved — Addressed
03/12/2026
Objection resolved — Addressed
03/12/2026
Objection resolved — Addressed
03/12/2026
Objection resolved — Addressed
03/12/2026
Objection resolved — Addressed
03/12/2026
Objection resolved — Addressed
03/12/2026
Objection resolved — Addressed
03/12/2026
Objection resolved — Addressed
03/12/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Chris Yiu
03/04/2026
Objection raised — Other
03/04/2026
Objection raised — Mechanical
03/04/2026
Objection raised — Plumbing
03/04/2026
Objection raised — Fire_Protection
02/23/2026
Objection raised — Zoning
02/23/2026
Objection raised — Cost
02/23/2026
Objection raised — Admin
02/23/2026
Objection raised — Zoning
02/23/2026
Objection raised — Admin
02/23/2026
Objection raised — Scope
02/23/2026
Objection raised — Admin
02/23/2026
Objection raised — Other
02/23/2026
Objection raised — Energy
02/23/2026
Objection raised — Fire_Protection
02/23/2026
Objection raised — Admin
02/19/2026
Permit issued — General Construction
B01205259-S3-GC
02/09/2026
Filed — Alteration CO
B01344763-I1
02/06/2026
Special inspection requirement — Tenant Protection Plan Compliance
CARL HAMANN
01/27/2026
Objection resolved — Addressed
01/27/2026
Objection resolved — Addressed
01/27/2026
Objection resolved — Addressed
01/15/2026
Objection resolved — Addressed
01/15/2026
Special inspection requirement — Fenestration areas
CARL HAMANN
01/15/2026
Special inspection requirement — Fire-Resistance Rated Construction
CARL HAMANN
01/15/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
CARL HAMANN
01/15/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
CARL HAMANN
01/15/2026
Special inspection requirement — Concrete - Cast-In-Place
CARL HAMANN
01/15/2026
Special inspection requirement — Fenestration air leakage
CARL HAMANN
01/14/2026
Objection resolved — Addressed
01/05/2026
Objection raised — Other
01/05/2026
Objection raised — Cost
01/05/2026
Objection raised — Admin
Latest 60 of 104 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BRIDGE ZALE CONSTRUCTION CORP.1607/08/2026
499 GRAHAM AVE, LLC203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/20/2024$1.1M—— → —$279/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
HAMANN ENGINEERING, PLLC607/15/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BRIDGE ZALE CONSTRUCT CORGeneral Contractor307/08/2026
NEW YORK PARK PLBG&HTG COPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HAMANN ENGINEERING, PLLC4949607/15/2026
STRUCT. ENGINEERING INTEG4174102/09/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedNEW YORK PARK PLBG&HTG CO06/24/2026
DOB NOWGeneral ConstructionPermit IssuedBRIDGE ZALE CONSTRUCT COR06/04/2026
DOB NOWGeneral ConstructionPermit IssuedBRIDGE ZALE CONSTRUCT COR02/19/2026
DOB NOWBoiler EquipmentPermit IssuedNEW YORK PARK PLBG&HTG CO10/07/2025
DOB NOWGeneral ConstructionPermit IssuedBRIDGE ZALE CONSTRUCT COR07/30/2025
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
08/19/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/13/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/10/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
07/09/2026Fail-Final General Construction Non-Directive 14FailView ↗
07/08/2026Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
06/30/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 18
DateRequirementInspectorRole
04/17/2026Air barrier - visual inspectionCARL HAMANNenergy_progress
04/17/2026Permanent certificateCARL HAMANNenergy_progress
04/17/2026Interior lighting powerCARL HAMANNenergy_progress
03/12/2026Structural Stability – Alterations of existing buildingsChris Yiuspecial
02/06/2026Tenant Protection Plan ComplianceCARL HAMANNspecial
01/15/2026Fenestration areasCARL HAMANNenergy_progress
01/15/2026Fire-Resistance Rated ConstructionCARL HAMANNprogress
01/15/2026Fenestration and door U-factor and product ratingsCARL HAMANNenergy_progress
01/15/2026Fire-Resistant Penetrations and JointsCARL HAMANNspecial
01/15/2026Concrete - Cast-In-PlaceCARL HAMANNspecial
01/15/2026Fenestration air leakageCARL HAMANNenergy_progress
04/23/2025Maintenance informationCARL HAMANNenergy_progress
04/23/2025Fire-Resistant Penetrations and JointsCARL HAMANNspecial
04/23/2025Heating SystemsCARL HAMANNspecial
04/23/2025HVAC-R and service water heating system controlsCARL HAMANNenergy_progress
04/23/2025HVAC-R and service water piping design and insulationCARL HAMANNenergy_progress
04/23/2025HVAC-R and service water heating equipmentCARL HAMANNenergy_progress
04/04/2025Tenant Protection Plan ComplianceCARL HAMANNspecial
▾Documents — 38 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/21/2026B01205827-I1Contact architect ↗
08/19/2026B01205259-I1Contact architect ↗
08/19/2026B01205259-P1Contact architect ↗
Showing 3 of 6 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/14/2026B01344763-I1Open ↗
▸Seals & Professional Certifications15
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/21/2026B01205827-I1Open ↗
08/19/2026B01205259-S1Open ↗
08/19/2026B01205259-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/23/2026B01205259-I1Open ↗
09/23/2026B01205259-I1Open ↗
09/23/2026B01205259-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
09/23/2026B01205259-I1Open ↗
08/26/2026B01344763-I1Open ↗
08/26/2026B01344763-I1Open ↗
▸Safety & Tenant Protection8
▸DOB NOWHPD-1: Anti-Harassment Area Checklist7
08/19/2026B01205259-P1Open ↗
08/14/2026B01344763-I1Open ↗
08/13/2026B01205259-S1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWStreet Tree Checklist1
08/13/2026B01344763-I1Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/19/2026B01205259-S1Open ↗
08/19/2026B01205259-I1Open ↗
08/19/2026B01205259-P1Open ↗
Showing 3 of 6 on file for this type
▸Other Documents2
▸DOB NOWProperty Ownership Certification1
08/14/2026B01344763-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026B01344763-I1Open ↗