← Back
Miscellaneous two family
67 JACKSON STREET
BROOKLYN · BIN 3068259
💬 Discuss this project
1901Year Built
2Stories
B9Building Class
R6BZoning
—Gross Floor Area
2Units
Miscellaneous two family · 1.19 FAR built · Flood zone X
Locations of Work
Architecture
Floor 11p · 1 filing · 14 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
WITHERS TOWER203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KWHC CONSULTING ENGINEER PLLC112/05/2025
MICHAEL HOUSE ARCHITECT, PLLC210/14/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NEXUS CONSULTING NYC, INC603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
A & R HOME IMPROVEMENT &General Contractor104/11/2026
MASTER INTERIORS CORPGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
KWHC CONSULTING ENGINEER9586212/05/2025
Building Lifecycle
All (12)Filed (3)Permit Issued (2)Signed Off (2)Objection (2)Special Inspection (3)
05/26/2026
Signed off — Alteration
Foundation work is proposed in the cellar to replace the wood posts with new steel posts. The general construction application has been submitted. All per submitted plans. No changes to use, egress, or occupancy.
B01272757-S1
04/09/2026
Signed off — Alteration
Foundation work is proposed in the cellar to replace the wood posts with new steel posts. The general construction application has been submitted. All per submitted plans. No changes to use, egress, or occupancy.
B01272757-I1
04/08/2026
Permit issued — Foundation
B01272757-S1-FO
12/17/2025
Permit issued — General Construction
B01272757-I1-GC
12/05/2025
Filed — Alteration
Foundation work is proposed in the cellar to replace the wood posts with new steel posts. The general construction application has been submitted. All per submitted plans. No changes to use, egress, or occupancy.
B01272757-S1
12/01/2025
Special inspection requirement — Concrete - Cast-In-Place
Kevin Cheng
10/28/2025
Special inspection requirement — Final
Kevin Cheng
10/28/2025
Special inspection requirement — Footing and Foundation
Kevin Cheng
10/14/2025
Filed — Alteration
Foundation work is proposed in the cellar to replace the wood posts with new steel posts. The general construction application has been submitted. All per submitted plans. No changes to use, egress, or occupancy.
B01272757-P1
09/25/2025
Objection resolved — Addressed
09/24/2025
Objection raised — Admin
09/19/2025
Filed — Alteration
Foundation work is proposed in the cellar to replace the wood posts with new steel posts. The general construction application has been submitted. All per submitted plans. No changes to use, egress, or occupancy.
B01272757-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWFoundationSigned-offA & R HOME IMPROVEMENT &04/08/2026
DOB NOWGeneral ConstructionSigned-offMASTER INTERIORS CORP12/17/2025
BISPLISSUEDP.H. WORKS INC02/19/2019
BISPLISSUEDOJ PLUMBING & HEATING INC06/24/1999
BIS—ISSUEDDOMINICK SIANO G'NL CONT06/02/1999
2 projects · most recent 12/16/2025
General Wiring
FiledStatusContractorScope
12/16/2025CompleteKGB ELEC'L CONTR'G CORPGeneral Wiring
09/17/2018CompleteBLZ ELECTRIC INC.General Wiring
1 project · most recent 12/05/2025
FiledStatusContractorScope
12/05/2025Signed-offA & R HOME IMPROVEMENT &1 scope_items
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
12/01/2025Concrete - Cast-In-PlaceKevin Chengspecial
10/28/2025FinalKevin Chengprogress
10/28/2025Footing and FoundationKevin Chengprogress
▾Documents — 27 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/20/2026B01272757-S1Request digital key ↗
08/20/2026B01272757-P1Request digital key ↗
08/20/2026B01272757-I1Request digital key ↗
▸Applications & Permits3
▸BISPLAN / WORK APPROVAL APPLICATION1
12/20/2018300807241Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
12/12/2018300807241Open ↗
▸BISWORK PERMIT APPLICATION1
02/19/2019300807241Open ↗
▸Zoning, Tax Lot & Property Records5
▸BISZONING EXHIBIT II: CERTIFICATION1
05/05/2021321600291Open ↗
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
05/05/2021321600291Open ↗
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
05/05/2021321600291Open ↗
▸BISZONING EXHIBIT IV: CERTIFICATION1
05/05/2021321600291Open ↗
▸BISZONING APPEAL1
12/20/2018300807241Open ↗
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/13/2026B01272757-S1Open ↗
08/13/2026B01272757-I1Open ↗
08/13/2026B01272757-P1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/30/2026B01272757-S1Open ↗
08/30/2026B01272757-S1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
07/25/2018300807241Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/30/2026B01272757-S1Open ↗
▸Trade Schedules & Equipment2
▸BISDETECTOR:SMOKE-CERT. OF INSTALLATION1
12/17/2018300807241Open ↗
▸BISPLUMBING - SUPPORTING DOCUMENTATION1
02/19/2019300807241Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/13/2026B01272757-I1Open ↗
08/13/2026B01272757-P1Open ↗
08/13/2026B01272757-S1Open ↗
▸Inspections & Test Reports2
▸DOB NOWGeotechnical Report (BC 1803.6)2
08/20/2026B01272757-S1Open ↗
08/13/2026B01272757-S1Open ↗
▸Filing & Intake Forms1
▸BISBOROUGH INTAKE FORM1
12/12/2018300807241Open ↗
▸Other Documents1
▸BISPLOT DIAGRAM1
05/05/2021321600291Open ↗