← Back
Primarily 4 family with 1 store or office
1540 DEKALB AVENUE
BROOKLYN · BIN 3073880
💬 Discuss this project
1931Year Built
3Stories
S4Building Class
R6Zoning
4,875 sfGross Floor Area
5Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Primarily 4 family with 1 store or office · Owner of record: DEKALB CORP · 2,500 sf lot · 1.95 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
1 job · most recent 09/01/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
09/01/2026——Heating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MXZ-3D30NLHZ 28,400 BTU · Condensing Unit ×4
3 jobs · most recent 08/18/2026
General Wiring
FiledStatusContractorScope
08/18/2026Permit IssuedRJ ELECTRICAL CONTRACTORS6 meters, 5 new_meters
02/08/2025Permit IssuedE & M ELECTRICAL NY CORPGeneral Wiring
05/29/2018CompleteSALVATORE CAMPISI & SONSGeneral Wiring
Building Lifecycle
All (49)Filed (4)Permit Issued (3)Signed Off (3)Violation (16)Inspection (3)Special Inspection (20)
09/01/2026
Filed — Alteration
INSTALL NEW AIR COOLED VRF SPLIT SYSTEM FOR 2ND, 3RD FLOOR FOR THE BUILDING, NO CHANGE IN USE, EGRESS AND OCCUPANCY.
B01435843-I1
07/23/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
YUE ZHOU
07/23/2026
Special inspection requirement — Mechanical Systems
YUE ZHOU
07/23/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
YUE ZHOU
07/23/2026
Special inspection requirement — Tenant Protection Plan Compliance
YUE ZHOU
07/23/2026
Special inspection requirement — Final
YUE ZHOU
07/23/2026
Special inspection requirement — Energy Code Compliance Inspections
YUE ZHOU
07/23/2026
Special inspection requirement — Fire-Resistance Rated Construction
YUE ZHOU
07/23/2026
Special inspection requirement — HVAC-R and service water heating system controls
YUE ZHOU
07/23/2026
Special inspection requirement — Maintenance information
YUE ZHOU
07/23/2026
Special inspection requirement — HVAC-R and service water heating equipment
YUE ZHOU
05/04/2026
Violation issued (HPD, closed)
A
11/20/2025
Violation issued (HPD, closed)
I
11/14/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/14/2025
Signed off — Alteration
APPLICATION FILED TO INSTALL NEW HOOD, EXHAUST FAN, MAKE-UP AIRUNIT, AND ASSOCIATED DUCT AS PER PLAN AT FIRST FLOOR. NO CHANGE INBULK, FLOOR AREA, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.
B01144791-I1
08/14/2025
Signed off — Alteration
FILING THIS APPLICATION TO INSTALL NEW PLUMBING FIXTURES IN EX.COMMERCIAL SPACE.NO CHANGE IN USE,EGRESS OR OCCUPANCY
B01144844-I1
06/11/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
06/09/2025
Violation issued (HPD, closed)
A
06/04/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/22/2025
Signed off — Alteration
APPLICATION FILED TO INSTALL NEW HOOD, EXHAUST FAN, MAKE-UP AIRUNIT, AND ASSOCIATED DUCT AS PER PLAN AT FIRST FLOOR. NO CHANGE INBULK, FLOOR AREA, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.
B01144791-S1
04/22/2025
Permit issued — Mechanical Systems
B01144791-S1-MS
04/14/2025
Filed — Alteration
APPLICATION FILED TO INSTALL NEW HOOD, EXHAUST FAN, MAKE-UP AIRUNIT, AND ASSOCIATED DUCT AS PER PLAN AT FIRST FLOOR. NO CHANGE INBULK, FLOOR AREA, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.
B01144791-S1
04/01/2025
Special inspection requirement — Mechanical Systems
SOHAIL HUMAYUN
04/01/2025
Special inspection requirement — Tenant Protection Plan Compliance
SOHAIL HUMAYUN
04/01/2025
Special inspection requirement — Final
SOHAIL HUMAYUN
03/10/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/28/2025
Permit issued — Plumbing
B01144844-I1-PL
01/09/2025
Permit issued — General Construction
B01144791-I1-GC
11/29/2024
Violation issued (HPD, closed)
I
11/24/2024
Filed — Alteration
APPLICATION FILED TO INSTALL NEW HOOD, EXHAUST FAN, MAKE-UP AIRUNIT, AND ASSOCIATED DUCT AS PER PLAN AT FIRST FLOOR. NO CHANGE INBULK, FLOOR AREA, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.
B01144791-I1
11/24/2024
Filed — Alteration
FILING THIS APPLICATION TO INSTALL NEW PLUMBING FIXTURES IN EX.COMMERCIAL SPACE.NO CHANGE IN USE,EGRESS OR OCCUPANCY
B01144844-I1
11/19/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Hung Pui Ho
11/19/2024
Special inspection requirement — Tenant Protection Plan Compliance
Hung Pui Ho
11/19/2024
Special inspection requirement — Fire-Resistance Rated Construction
Hung Pui Ho
11/19/2024
Special inspection requirement — Final
Hung Pui Ho
11/19/2024
Special inspection requirement — Interior lighting power
Hung Pui Ho
11/19/2024
Special inspection requirement — Lighting controls
Hung Pui Ho
11/19/2024
Special inspection requirement — Tenant Protection Plan Compliance
Hung Pui Ho
11/22/2023
Violation issued (HPD, closed)
I
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/08/2021
Violation issued (HPD, closed)
A
04/06/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/04/2016
Violation issued (HPD, closed)
I
12/31/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/13/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/19/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/01/1990
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
DEKALB1203/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CNY ENGINEERING P.C109/01/2026
SOHAIL HUMAYUN P E INC104/14/2025
1+1 DESIGN STUDIO LLC211/24/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JRK CREATIVE203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
FIRE ZONE VENTILATION & SGeneral Contractor107/08/2026
QUALITY G BUILDERS INCGeneral Contractor107/08/2026
CM PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CNY ENGINEERING P.C3304109/01/2026
SOHAIL HUMAYUN P E INC8457104/14/2025
1+1 DESIGN STUDIO LLC1039211/24/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offFIRE ZONE VENTILATION S04/22/2025
DOB NOWPlumbingSigned-offCM PLUMBING INC02/28/2025
DOB NOWGeneral ConstructionSigned-offQUALITY G BUILDERS INC01/09/2025
BISMHISSUEDFORTRESS CONSTRUCTION LLC03/06/2019
BISPLISSUEDRUGOVA GROUP LLC03/06/2019
BISPLISSUEDCK PLUMBING & MECH INC01/31/2012
BISOTISSUEDFORTRESS CONSTRUCTION LLC01/12/2012
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
06/11/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/04/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/10/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 20
DateRequirementInspectorRole
07/23/2026HVAC-R and service water piping design and insulationYUE ZHOUenergy_progress
07/23/2026Mechanical SystemsYUE ZHOUspecial
07/23/2026Fire-Resistant Penetrations and JointsYUE ZHOUspecial
07/23/2026Tenant Protection Plan ComplianceYUE ZHOUspecial
07/23/2026FinalYUE ZHOUprogress
07/23/2026Energy Code Compliance InspectionsYUE ZHOUprogress
07/23/2026Fire-Resistance Rated ConstructionYUE ZHOUprogress
07/23/2026HVAC-R and service water heating system controlsYUE ZHOUenergy_progress
07/23/2026Maintenance informationYUE ZHOUenergy_progress
07/23/2026HVAC-R and service water heating equipmentYUE ZHOUenergy_progress
04/01/2025Mechanical SystemsSOHAIL HUMAYUNspecial
04/01/2025Tenant Protection Plan ComplianceSOHAIL HUMAYUNspecial
04/01/2025FinalSOHAIL HUMAYUNprogress
11/19/2024Fire-Resistant Penetrations and JointsHung Pui Hospecial
11/19/2024Tenant Protection Plan ComplianceHung Pui Hospecial
11/19/2024Fire-Resistance Rated ConstructionHung Pui Hoprogress
11/19/2024FinalHung Pui Hoprogress
11/19/2024Interior lighting powerHung Pui Hoenergy_progress
11/19/2024Lighting controlsHung Pui Hoenergy_progress
11/19/2024Tenant Protection Plan ComplianceHung Pui Hospecial
▾Documents — 88 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
09/14/2026B01435843-I1Request digital key ↗
08/23/2026B01144844-I1Request digital key ↗
08/21/2026B01144791-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits11
▸BISPLAN / WORK APPROVAL APPLICATION6
06/21/2019321924370Open ↗
05/29/2019321924370Open ↗
02/08/2019321924370Open ↗
Showing 3 of 6 on file for this type
▸BISWORK PERMIT APPLICATION4
03/07/2019321924370Open ↗
03/07/2019321924370Open ↗
02/01/2012320367278Open ↗
Showing 3 of 4 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
04/24/2019321924370Open ↗
▸Seals & Professional Certifications31
▸DOB NOWProgress Inspector Seal & Signature10
09/23/2026B01435843-I1Open ↗
09/23/2026B01435843-I1Open ↗
09/23/2026B01435843-I1Open ↗
Showing 3 of 10 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION8
06/28/2019321924370Open ↗
06/21/2019321924370Open ↗
03/07/2019321924370Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/23/2026B01435843-I1Open ↗
09/23/2026B01435843-I1Open ↗
09/23/2026B01435843-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
09/14/2026B01435843-I1Open ↗
08/21/2026B01144791-S1Open ↗
08/21/2026B01144791-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
02/08/2019321924370Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
02/08/2019321924370Open ↗
▸Trade Schedules & Equipment15
▸BISSCHEDULE B - PLUMBING3
04/16/2012320367278Open ↗
04/05/2012320367278Open ↗
10/27/2011320367278Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT3
06/21/2019321924370Open ↗
08/23/2013320367278Open ↗
10/27/2011320367278Open ↗
▸BISEQUIPMENT USE PERMITS3
06/21/2019321924370Open ↗
11/27/2013320367278Open ↗
08/23/2013320367278Open ↗
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE3
06/21/2019321924370Open ↗
05/29/2019321924370Open ↗
02/08/2019321924370Open ↗
▸BISSELF-CERT PLUMBING NOTICE2
05/14/2012320367278Open ↗
03/14/2012320367278Open ↗
▸BISPLUMBING - SUPPORTING DOCUMENTATION1
04/24/2019321924370Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
02/08/2019321924370Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
09/14/2026B01435843-I1Open ↗
08/21/2026B01144791-S1Open ↗
08/21/2026B01144791-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTHIS IS NOT AN ASBESTOS PROJECT2
10/27/2011320367278Open ↗
10/27/2011320367278Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
02/08/2019321924370Open ↗
▸Energy Compliance7
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS4
06/21/2019321924370Open ↗
03/07/2019321924370Open ↗
02/08/2019321924370Open ↗
Showing 3 of 4 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS2
06/21/2019321924370Open ↗
08/23/2013320367278Open ↗
▸BISTR8: Energy Code Progress Inspections1
10/27/2011320367278Open ↗
▸Approvals, Objections & Sign-offs3
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
06/28/2019321924370Open ↗
06/21/2019321924370Open ↗
08/23/2013320367278Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT4
06/21/2019321924370Open ↗
02/08/2019321924370Open ↗
08/23/2013320367278Open ↗
Showing 3 of 4 on file for this type
▸Filing & Intake Forms5
▸BISEFILING COVER SHEET2
02/08/2019321924370Open ↗
10/27/2011320367278Open ↗
▸BISBOROUGH INTAKE FORM2
06/28/2019321924370Open ↗
06/21/2019321924370Open ↗
▸BISADDITIONAL INFORMATION1
04/16/2012320367278Open ↗