← Back
Two family frame
1129 HANCOCK STREET
BROOKLYN · BIN 3077912
💬 Discuss this project
1910Year Built
2Stories
B2Building Class
R6Zoning
—Gross Floor Area
2Units
Two family frame · 1.35 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
4569 EQUITIES203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AMMOR ARCHITECTURE LLP202/24/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JM ZONING, LLC.403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BILLY SERVULUSElectrical103/21/2026
SERVULUS BILLYElectrical103/21/2026
GRANT DAVIS THOMPSON INCGeneral Contractor107/08/2026
ASPECT PLBNG&HTNG CO LLCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AMMOR ARCHITECTURE LLP3054102/24/2023
Building Lifecycle
All (13)Filed (2)Permit Issued (2)Signed Off (2)Inspection (2)Special Inspection (5)
08/11/2023
Signed off — Alteration
ALTERATIONS TO EXISTING DWELLING. MINOR RELOCATION OF NON LOAD-BEARING INTERIOR PARTITION ON SECOND FLOOR ONLY. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00829158-I1
08/10/2023
Signed off — Alteration
PLUMBING APPLICATION FILED IN CONJUCTION WITH INTERIOR RENOVATION. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00829159-I1
08/03/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/12/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/30/2023
Permit issued — Plumbing
B00829159-I1-PL
03/02/2023
Permit issued — General Construction
B00829158-I1-GC
02/24/2023
Filed — Alteration
ALTERATIONS TO EXISTING DWELLING. MINOR RELOCATION OF NON LOAD-BEARING INTERIOR PARTITION ON SECOND FLOOR ONLY. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00829158-I1
02/24/2023
Filed — Alteration
PLUMBING APPLICATION FILED IN CONJUCTION WITH INTERIOR RENOVATION. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00829159-I1
02/23/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Thomas Morbitzer
02/23/2023
Special inspection requirement — Energy Code Compliance Inspections
Thomas Morbitzer
02/23/2023
Special inspection requirement — Lighting controls
Thomas Morbitzer
02/23/2023
Special inspection requirement — Lighting in dwelling units
Thomas Morbitzer
02/14/2023
Special inspection requirement — Final
Thomas Morbitzer
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offASPECT PLBNG&HTNG CO LLC03/30/2023
DOB NOWGeneral ConstructionSigned-offGRANT DAVIS THOMPSON INC03/02/2023
BISPLISSUEDPLBG P & H INC01/08/2016
BISMHISSUEDDOPPLER INNOVATIONS INC12/18/2015
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
08/03/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/12/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
02/23/2023Fire-Resistant Penetrations and JointsThomas Morbitzerspecial
02/23/2023Energy Code Compliance InspectionsThomas Morbitzerprogress
02/23/2023Lighting controlsThomas Morbitzerenergy_progress
02/23/2023Lighting in dwelling unitsThomas Morbitzerenergy_progress
02/14/2023FinalThomas Morbitzerprogress
▾Documents — 32 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/27/2026B00829159-I1Request digital key ↗
08/27/2026B00829158-I1Request digital key ↗
▸Applications & Permits5
▸BISWORK PERMIT APPLICATION3
01/21/2016321290296Open ↗
12/22/2015321290296Open ↗
12/22/2015321290296Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION2
10/07/2016321290296Open ↗
12/22/2015321290296Open ↗
▸Seals & Professional Certifications11
▸DOB NOWProgress Inspector Seal & Signature4
08/23/2026B00829158-I1Open ↗
08/23/2026B00829158-I1Open ↗
08/23/2026B00829158-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
08/19/2016321290296Open ↗
12/22/2015321290296Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026B00829159-I1Open ↗
08/13/2026B00829158-I1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
12/22/2015321290296Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
12/22/2015321290296Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026B00829158-I1Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
10/07/2016321290296Open ↗
12/22/2015321290296Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
12/22/2015321290296Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026B00829158-I1Open ↗
08/13/2026B00829159-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
12/22/2015321290296Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
08/19/2016321290296Open ↗
12/22/2015321290296Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
08/19/2016321290296Open ↗
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
10/26/2016321290296Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
10/26/2016321290296Open ↗
12/22/2015321290296Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET1
12/22/2015321290296Open ↗
▸BISADDITIONAL INFORMATION1
10/07/2016321290296Open ↗