← Back
Five to six families
1423 BUSHWICK AVENUE
BROOKLYN · BIN 3080072
💬 Discuss this project
1906Year Built
3Stories
C2Building Class
R6Zoning
5,625 sfGross Floor Area
6Units
Rent Stabilized47 Open Violations 46 unresolved · 1 paperwork only ▸FDNY Report ↗
Five to six families · Owner of record: VANGELUS LLC · 2,425 sf lot · 2.32 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingCivilGeneral
Permit Issued — active, not yet Signed-off
Roof5p · 1 filing · 9 docs
Floor 3Under Construction13p · 5 filings · 20 docs
Floor 2Under Construction6p · 3 filings · 11 docs
Floor 1Under Construction6p · 3 filings · 17 docs
CellarUnder Construction4p · 3 filings · 17 docs
1 job · most recent 08/25/2024
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
08/25/2024——Heating and Air Conditioning Systems
Heat / Cool
Daikin Daikin DRG0361DL000015 18 tons · Rooftop Unit ×6
2 jobs · most recent 06/30/2026
Gas Water/Sanitary
FiledStatusContractorScope
06/30/2026——Gas, Water/Sanitary
12/18/2025——Gas, Water/Sanitary
2 jobs · most recent 01/21/2026
Boiler Controls
FiledStatusContractorScope
01/21/2026Permit IssuedRICHARD NEU—
06/05/2018CompleteE.N.E.L. ELECTRICAL CORPBoiler Controls
3 jobs · most recent 10/23/2025
Wood
FiledStatusContractorScope
10/23/2025Permit IssuedR & E RENOVATIONS CORP2 scope_items
08/25/2024——Wood
08/17/2023Permit Issued5D ARCHITECT AND ENGINEER1 scope_items
1 job · most recent 01/20/2026
Sidewalk Shed
FiledStatusContractorScope
01/20/2026Permit IssuedR&A CONSTR SERVICES INCSidewalk Shed
Building Lifecycle
All (181)Filed (9)Permit Issued (7)Violation (60)Objection (79)Special Inspection (26)
07/14/2026
Objection resolved — Resolved
07/10/2026
Objection raised — Other
06/30/2026
Filed — Alteration
Interior renovation of 2nd floor and replace stair
B01423757-I1
06/30/2026
Filed — Alteration
replace existing plumbing fixtures with new
B01423799-I1
06/22/2026
Permit issued — General Construction
B01334381-I1-GC
05/19/2026
Permit issued — General Construction
B01284578-I1-GC-CX
05/04/2026
Violation issued (HPD, open)
A
01/23/2026
Permit issued — Sidewalk Shed
B01347583-I1-SH
01/20/2026
Filed — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED AS PER PLANS. LIVE LOAD 300 LBS PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
B01347583-I1
12/18/2025
Filed — Alteration
replace existing plumbing fixtures with new
B01334381-S1
12/18/2025
Filed — Alteration
replace existing plumbing fixtures with new
B01334381-I1
12/16/2025
Permit issued — General Construction
B01284578-I1-GC-CX
12/15/2025
Special inspection requirement — Final
NAVEEN KUMAR
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/12/2025
Objection resolved — Addressed
11/12/2025
Objection resolved — Addressed
11/12/2025
Objection resolved — Addressed
11/11/2025
Objection resolved — Addressed
11/05/2025
Objection raised — Scope
11/05/2025
Objection raised — Other
11/05/2025
Objection raised — Cost
11/05/2025
Objection raised — Scope
10/23/2025
Filed — Alteration
Bracing of existing fire damaged joist and roof rafters to remove VIOLATION #V020723C23-00355
B01284578-I1
09/11/2025
Special inspection requirement — Structural Cold-Formed Steel
Younes Abouyaala
09/10/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Younes Abouyaala
09/09/2025
Special inspection requirement — Final
NAVEEN KUMAR
06/06/2025
Violation issued (HPD, open)
A
05/03/2025
Special inspection requirement — Fenestration air leakage
JACKMAN PRESCOD
05/03/2025
Special inspection requirement — Permanent certificate
JACKMAN PRESCOD
05/03/2025
Special inspection requirement — Air barrier - visual inspection
JACKMAN PRESCOD
05/03/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
JACKMAN PRESCOD
03/19/2025
Objection resolved — Addressed
03/19/2025
Objection resolved — Addressed
03/18/2025
Objection resolved — Addressed
01/29/2025
Objection resolved — Addressed
01/29/2025
Objection resolved — Addressed
01/29/2025
Objection resolved — Addressed
01/29/2025
Objection resolved — Addressed
01/13/2025
Objection resolved — Addressed
01/13/2025
Special inspection requirement — HVAC-R and service water heating system controls
01/13/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
01/13/2025
Special inspection requirement — HVAC-R and service water heating equipment
12/18/2024
Objection resolved — Addressed
11/26/2024
Violation issued (HPD, closed)
I
11/06/2024
Objection resolved — Addressed
11/06/2024
Objection resolved — Addressed
10/09/2024
Objection resolved — Addressed
10/09/2024
Objection resolved — Addressed
10/09/2024
Objection resolved — Addressed
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/19/2024
Objection raised — Topo verification required to
08/29/2024
Objection raised — Scope
08/29/2024
Objection raised — Scope
08/29/2024
Objection raised — Structural
08/29/2024
Objection raised — Mechanical
08/29/2024
Objection raised — Scope
08/29/2024
Objection raised — Structural
08/29/2024
Objection raised — Mechanical
08/28/2024
Objection resolved — Addressed
08/25/2024
Filed — Alteration CO
GUT RENOVATION REHAB ON ALL FLOORS TO ADDRESS FIRE DAMAGE AND ROOF REPLACEMENT. RELOCATE MAIN CENTRAL STAIR ENTRANCE TO COMPLY WITH NEW BUILDING CODE SAFETY, EGRESS, AND ZONING REQUIREMENTS.
B00952538-S1
Latest 60 of 181 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
5D ARCHITECTURE ENGINEERING1507/08/2026
R&A CONSTRUCTION SERVICES INC.503/22/2026
VANGELUS LLC203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/31/2022$600K—— → —$107/sf building
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
5D ARCHITECTURE ENGINEERING603/21/2026
SNR EXPEDITING DESIGN203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
5D ARCHITECT AND ENGINEERGeneral Contractor707/08/2026
R&A CONSTR SERVICES INCGeneral Contractor303/21/2026
R & E RENOVATIONS, INCGeneral Contractor306/28/2026
E.N.E.L. ELECTRICAL CORPElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AA BUILDING & INSPECTION1519110/23/2025
5D ARCH. & ENG., PLLC2781210/25/2023
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedR & E RENOVATIONS, INC06/22/2026
DOB NOWGeneral ConstructionPermit IssuedR & E RENOVATIONS, INC05/19/2026
DOB NOWSidewalk ShedPermit IssuedR&A CONSTR SERVICES INC01/23/2026
DOB NOWGeneral ConstructionPermit IssuedR & E RENOVATIONS CORP12/16/2025
DOB NOWGeneral ConstructionPermit Issued5D ARCHITECT AND ENGINEER11/01/2023
DOB NOWStructuralPermit Issued5D ARCHITECT AND ENGINEER09/19/2023
DOB NOWStructuralPermit Issued5D ARCHITECT AND ENGINEER08/23/2023
▾Special Inspection Requirements (DOB NOW) — 26
DateRequirementInspectorRole
12/15/2025FinalNAVEEN KUMARprogress
09/11/2025Structural Cold-Formed SteelYounes Abouyaalaspecial
09/10/2025Structural Stability – Alterations of existing buildingsYounes Abouyaalaspecial
09/09/2025FinalNAVEEN KUMARprogress
05/03/2025Fenestration air leakageJACKMAN PRESCODenergy_progress
05/03/2025Permanent certificateJACKMAN PRESCODenergy_progress
05/03/2025Air barrier - visual inspectionJACKMAN PRESCODenergy_progress
05/03/2025Fenestration and door U-factor and product ratingsJACKMAN PRESCODenergy_progress
01/13/2025HVAC-R and service water heating system controls—energy_progress
01/13/2025HVAC-R and service water piping design and insulation—energy_progress
01/13/2025HVAC-R and service water heating equipment—energy_progress
08/21/2024Insulation placement and R values—energy_progress
08/21/2024Lighting in dwelling units—energy_progress
08/21/2024Interior lighting power—energy_progress
08/21/2024Demolition—special
08/21/2024Masonry—special
08/21/2024Structural Stability – Alterations of existing buildings—special
08/21/2024Structural Steel - High Strength Bolting—special
08/21/2024Structural Steel - Welding—special
08/21/2024Structural Cold-Formed Steel—special
08/21/2024Energy Code Compliance Inspections—progress
08/21/2024Fire-Resistance Rated Construction—progress
08/21/2024Exterior lighting power—energy_progress
08/21/2024Concrete - Cast-In-Place—special
10/24/2023FinalJACKMAN PRESCODprogress
Latest 25 of 26.
▾Documents — 33 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/27/2026B00921411-I1Request digital key ↗
08/26/2026B00952538-S1Request digital key ↗
08/26/2026B00952538-I1Request digital key ↗
Showing 3 of 8 on file for this type
▸Seals & Professional Certifications15
▸DOB NOWDPL-1: Design Professional Seal & Signature9
08/19/2026B01334381-S1Open ↗
08/19/2026B01334381-I1Open ↗
08/16/2026B01423757-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
09/01/2026B01284578-I1Open ↗
08/24/2026B00952538-I1Open ↗
08/24/2026B00952538-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature1
09/01/2026B01284578-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/19/2026B01334381-I1Open ↗
08/19/2026B01334381-S1Open ↗
08/16/2026B01423799-I1Open ↗
Showing 3 of 5 on file for this type
▸Other Documents5
▸DOB NOWDHCR Document5
08/13/2026B01334381-I1Open ↗
08/13/2026B00921411-I1Open ↗
08/13/2026B00952538-S1Open ↗
Showing 3 of 5 on file for this type