← Back
Miscellaneous one family
438 MOTHER GASTON BLVD
BROOKLYN · BIN 3081154
💬 Discuss this project
1920Year Built
2Stories
A9Building Class
R6Zoning
1,800 sfGross Floor Area
1Units
Miscellaneous one family · 2,500 sf lot · 0.72 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectrical
Roof3p · 1 filing · 7 docs
Cellar5p · 1 filing · 10 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CMO ASSOCIATES LLC205/21/2025
TOM PETERSEN ARCHITECT, LLC104/14/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUNCO CAPITAL203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
A.N.C. CONTRACTING CO.,INGeneral Contractor203/21/2026
SUNCO CAPITAL LLCGeneral Contractor203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SUPERIOR - HOME INSPECTIO1804205/21/2025
THOMAS PETERSEN ARCHITECT7854104/14/2025
Building Lifecycle
All (27)Filed (3)Permit Issued (2)Objection (8)Special Inspection (14)
05/22/2025
Special inspection requirement — Concrete - Cast-In-Place
Steven Williams
05/22/2025
Special inspection requirement — Final
CHRISTIAN ONYECHI
05/22/2025
Special inspection requirement — Underpinning
Steven Williams
05/22/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Steven Williams
05/21/2025
Filed — Alteration
TO EXCAVATE EXISTING CELLAR FLOOR DOWN 24" PROVIDING REINFORCED CONCRETE UNDERPINNING FOR FOOTING IN EFFECTIVE ARE. NEW REINFORCED 4" CONCRETE ON SLAB ON GRADE. ALSO NEW EXTERIOR STEPS AT SIDE YARD.
B01191260-P1
05/19/2025
Permit issued — Solar
B01208846-I1-SL
05/01/2025
Objection resolved — Addressed
05/01/2025
Objection resolved — Addressed
05/01/2025
Objection resolved — Addressed
05/01/2025
Objection resolved — Addressed
04/30/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Steven Williams
04/30/2025
Special inspection requirement — Concrete - Cast-In-Place
Steven Williams
04/30/2025
Special inspection requirement — Underpinning
Steven Williams
04/30/2025
Special inspection requirement — Final
CHRISTIAN ONYECHI
04/25/2025
Objection raised — Cost
04/25/2025
Objection raised — Fire_Protection
04/25/2025
Objection raised — Fire_Protection
04/25/2025
Objection raised — Admin
04/14/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B01208846-I1
04/11/2025
Permit issued — General Construction
B01191260-I1-GC
04/10/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
04/10/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
04/10/2025
Special inspection requirement — Final
TOM PETERSEN
04/10/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
04/10/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
04/10/2025
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
TOM PETERSEN
03/26/2025
Filed — Alteration
TO EXCAVATE EXISTING CELLAR FLOOR DOWN 24" PROVIDING REINFORCED CONCRETE UNDERPINNING FOR FOOTING IN EFFECTIVE ARE. NEW REINFORCED 4" CONCRETE ON SLAB ON GRADE. ALSO NEW EXTERIOR STEPS AT SIDE YARD.
B01191260-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedSUNCO CAPITAL LLC05/19/2025
DOB NOWGeneral ConstructionPermit IssuedA.N.C. CONTRACTING CO.,IN04/11/2025
2 projects · most recent 05/11/2025
General Wiring
FiledStatusContractorScope
05/11/2025CompleteCREATIVE CABLNG & BERTRAMGeneral Wiring
04/14/2025Permit IssuedBERGER QUALITY ELEC'L CON—
1 project · most recent 04/14/2025
FiledStatusContractorScope
04/14/2025Permit IssuedSUNCO CAPITAL LLC27 panels, 11.61 kw, 1,213 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 14
DateRequirementInspectorRole
05/22/2025Concrete - Cast-In-PlaceSteven Williamsspecial
05/22/2025FinalCHRISTIAN ONYECHIprogress
05/22/2025UnderpinningSteven Williamsspecial
05/22/2025Structural Stability – Alterations of existing buildingsSteven Williamsspecial
04/30/2025Structural Stability – Alterations of existing buildingsSteven Williamsspecial
04/30/2025Concrete - Cast-In-PlaceSteven Williamsspecial
04/30/2025UnderpinningSteven Williamsspecial
04/30/2025FinalCHRISTIAN ONYECHIprogress
04/10/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
04/10/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
04/10/2025FinalTOM PETERSENprogress
04/10/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
04/10/2025Energy Code Compliance InspectionsTOM PETERSENprogress
04/10/2025Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)TOM PETERSENspecial
▾Documents — 17 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/21/2026B01208846-I1Request digital key ↗
08/21/2026B01191260-I1Request digital key ↗
08/21/2026B01191260-P1Request digital key ↗
▸Seals & Professional Certifications11
▸DOB NOWProgress Inspector Seal & Signature4
09/01/2026B01191260-I1Open ↗
08/28/2026B01191260-P1Open ↗
08/25/2026B01208846-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/01/2026B01191260-I1Open ↗
08/28/2026B01191260-P1Open ↗
08/25/2026B01208846-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/21/2026B01191260-I1Open ↗
08/21/2026B01191260-P1Open ↗
08/13/2026B01208846-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/21/2026B01191260-P1Open ↗
08/21/2026B01191260-I1Open ↗
08/13/2026B01208846-I1Open ↗