← Back
Four families
572 NEW JERSEY AVENUE
BROOKLYN · BIN 3084682
💬 Discuss this project
1930Year Built
2Stories
C3Building Class
R6Zoning
3,116 sfGross Floor Area
4Units
Rent Stabilized4 Open Violations ▸FDNY Report ↗
Four families · 2,550 sf lot · 1.22 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof3p · 1 filing · 6 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
185 HEGEMAN LLC503/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NY BUILDING ASSOCIATES INC104/22/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
S R SOLAR DESIGN203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SURF CLEAN ENERGY INCGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244104/22/2025
Building Lifecycle
All (29)Filed (1)Permit Issued (1)Violation (16)Objection (6)Special Inspection (5)
05/05/2026
Violation issued (HPD, open)
A
06/25/2025
Permit issued — Solar
B01212803-I1-SL
06/10/2025
Violation issued (HPD, open)
A
06/06/2025
Objection resolved — Addressed
06/06/2025
Objection resolved — Addressed
05/08/2025
Objection resolved — Addressed
05/07/2025
Objection raised — Fire_Protection
05/07/2025
Objection raised — Fire_Protection
05/07/2025
Objection raised — Fire_Protection
04/22/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. NO CHANGE IN BULK
B01212803-I1
04/18/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
04/18/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
NARESH MAHANGU
04/18/2025
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
04/18/2025
Special inspection requirement — Final
NARESH MAHANGU
04/18/2025
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
04/11/2024
Violation issued (HPD, open)
A
11/17/2023
Violation issued (HPD, closed)
I
03/01/2022
Violation issued (HPD, closed)
A
04/12/2021
Violation issued (HPD, closed)
A
04/12/2021
Violation issued (HPD, closed)
I
10/31/2019
Violation issued (HPD, closed)
I
10/19/2018
Violation issued (HPD, closed)
I
11/14/2016
Violation issued (HPD, closed)
I
10/13/2015
Violation issued (HPD, closed)
I
04/19/2015
Violation issued (HPD, closed)
B
02/23/2015
Violation issued (HPD, closed)
I
09/11/2013
Violation issued (HPD, open)
B
10/10/2012
Violation issued (HPD, closed)
B
11/10/2005
Violation issued (HPD, closed)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedSURF CLEAN ENERGY INC06/25/2025
1 project · most recent 04/08/2025
FiledStatusContractorScope
04/08/2025Permit IssuedAMPACITY ELECTRICAL INC—
1 project · most recent 04/22/2025
FiledStatusContractorScope
04/22/2025Permit IssuedSURF CLEAN ENERGY INC13 panels, 5.52 kw, 2,340 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
04/18/2025Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
04/18/2025Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
04/18/2025Energy Code Compliance InspectionsNARESH MAHANGUprogress
04/18/2025FinalNARESH MAHANGUprogress
04/18/2025Air barrier - visual inspectionNARESH MAHANGUenergy_progress
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/21/2026B01212803-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
08/31/2026B01212803-I1Open ↗
08/31/2026B01212803-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/21/2026B01212803-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/31/2026B01212803-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/21/2026B01212803-I1Open ↗