← Back
Two family frame
104 ELTON STREET
BROOKLYN · BIN 3087083
💬 Discuss this project
1920Year Built
2.5Stories
B2Building Class
R4Zoning
1,821 sfGross Floor Area
2Units
2 Open Violations 0 unresolved · 2 paperwork only ▸FDNY Report ↗
Two family frame · 2,500 sf lot · 0.73 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Cellar3p · 1 filing · 7 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NETDT807/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
POST & LINTEL204/16/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NETDT LLCGeneral Contractor107/08/2026
ALL PRO PLBG & HTG INCPlumbing107/08/2026
Building Lifecycle
All (11)Filed (2)Permit Issued (2)Signed Off (1)Violation (6)
12/11/2025
Violation issued (ECB, closed)
Construction
08/10/2023
Signed off — Alteration
1. REMOVE ALL NON LOAD BEARING PARTITION WALL IN THE CELLAR.2. INSTALL 2 PCS POWDER ROOM AND STORAGE ROOM IN THE CELLAR AS PER PLAN.3. ADDRESS ECB VIOLATION# 39077694M 4. PLUMBING JOB WILL BE FILED UNDER SEPARATE APPLICATION.
B00857713-I1
06/08/2023
Permit issued — Plumbing
B00857713-S1-PL
06/07/2023
Permit issued — General Construction
B00857713-I1-GC
04/16/2023
Filed — Alteration
1. REMOVE ALL NON LOAD BEARING PARTITION WALL IN THE CELLAR.2. INSTALL 2 PCS POWDER ROOM AND STORAGE ROOM IN THE CELLAR AS PER PLAN.3. ADDRESS ECB VIOLATION# 39077694M 4. PLUMBING JOB WILL BE FILED UNDER SEPARATE APPLICATION.
B00857713-S1
04/14/2023
Filed — Alteration
1. REMOVE ALL NON LOAD BEARING PARTITION WALL IN THE CELLAR.2. INSTALL 2 PCS POWDER ROOM AND STORAGE ROOM IN THE CELLAR AS PER PLAN.3. ADDRESS ECB VIOLATION# 39077694M 4. PLUMBING JOB WILL BE FILED UNDER SEPARATE APPLICATION.
B00857713-I1
01/13/2023
Violation issued (ECB, closed)
Construction
01/13/2023
Violation issued (ECB, open)
Construction
03/12/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/21/2013
Violation issued (ECB, closed)
Construction
12/21/2013
Violation issued (ECB, open)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedALL PRO PLBG & HTG INC06/08/2023
DOB NOWGeneral ConstructionSigned-offNETDT LLC06/07/2023
1 project · most recent 04/16/2023
Gas Water/Sanitary
FiledStatusContractorScope
04/16/2023Permit IssuedALL PRO PLBG & HTG INCGas, Water/Sanitary
▾Special Inspection Requirements (DOB NOW) — 1
DateRequirementInspectorRole
04/11/2023FinalWALEED AFRIDIprogress
▾Documents — 14 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/15/2026B00857713-S1Request digital key ↗
08/14/2026B00857713-I1Request digital key ↗
▸Applications & Permits1
▸BISPLAN / WORK APPROVAL APPLICATION1
09/30/2016321458454Open ↗
▸Seals & Professional Certifications4
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/27/2026B00857713-S1Open ↗
08/27/2026B00857713-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
09/30/2016321458454Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/25/2026B00857713-I1Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
09/30/2016321458454Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/15/2026B00857713-S1Open ↗
08/14/2026B00857713-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
09/30/2016321458454Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
09/30/2016321458454Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
09/30/2016321458454Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
09/30/2016321458454Open ↗