← Back
Two family frame
198 ESSEX STREET
BROOKLYN · BIN 3088101
💬 Discuss this project
1901Year Built
2Stories
B2Building Class
R5BZoning
1,876 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family frame · 1,050 sf lot · 1.79 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TSS ENGINEERS508/25/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JENNY FLORES EXPEDITING503/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
V&B ELECTRICAL CONTNG INCElectrical103/22/2026
EZ RUNER CONSTRUCTION CORGeneral Contractor107/08/2026
EZ RUNER CONSTRUCTION CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
TSS ENGINEERS4492508/25/2021
Building Lifecycle
All (45)Filed (5)Permit Issued (2)Signed Off (2)Violation (7)Inspection (5)Objection (12)Special Inspection (12)
09/13/2021
Signed off — Alteration
HEREBY FILING FOR THE LEGALIZATION OF BATHROOMS AND INSTALLATION OF GAS DRYER TO ADDRESS VIOLATIONS 35413801N 35477249L. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00490109-I1
09/13/2021
Signed off — Alteration
B00490107-I1
08/31/2021
Objection resolved — Addressed
08/31/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
bassam (sam) rimawi
08/31/2021
Special inspection requirement — Energy Code Compliance Inspections
bassam (sam) rimawi
08/31/2021
Special inspection requirement — Maintenance information
bassam (sam) rimawi
08/30/2021
Objection resolved — Addressed
08/29/2021
Objection raised — Scope
08/29/2021
Objection raised — Scope
08/25/2021
Filed — Alteration
HEREBY FILING FOR THE LEGALIZATION OF BATHROOMS AND INSTALLATION OF GAS DRYER TO ADDRESS VIOLATIONS 35413801N 35477249L. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00490109-P3
08/17/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
bassam (sam) rimawi
08/17/2021
Special inspection requirement — Energy Code Compliance Inspections
bassam (sam) rimawi
08/17/2021
Special inspection requirement — Maintenance information
bassam (sam) rimawi
08/06/2021
Objection raised — Scope
08/06/2021
Objection resolved — Addressed
08/06/2021
Objection raised — Scope
08/06/2021
Objection resolved — Addressed
08/04/2021
Filed — Alteration
HEREBY FILING FOR THE LEGALIZATION OF BATHROOMS AND INSTALLATION OF GAS DRYER TO ADDRESS VIOLATIONS 35413801N 35477249L. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00490109-P2
07/29/2021
Special inspection requirement — Maintenance information
bassam (sam) rimawi
07/29/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
bassam (sam) rimawi
07/29/2021
Special inspection requirement — Energy Code Compliance Inspections
bassam (sam) rimawi
07/27/2021
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/23/2021
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/19/2021
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/19/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/19/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/29/2021
Filed — Alteration
HEREBY FILING FOR THE LEGALIZATION OF BATHROOMS AND INSTALLATION OF GAS DRYER TO ADDRESS VIOLATIONS 35413801N 35477249L. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00490109-P1
06/25/2021
Special inspection requirement — Energy Code Compliance Inspections
bassam (sam) rimawi
06/25/2021
Special inspection requirement — Maintenance information
bassam (sam) rimawi
06/25/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
bassam (sam) rimawi
05/19/2021
Permit issued — General Construction
B00490107-I1-GC
05/12/2021
Permit issued — Plumbing
B00490109-I1-PL
03/25/2021
Objection raised — Scope
03/25/2021
Objection resolved — Addressed
03/25/2021
Objection raised — Energy
03/25/2021
Objection resolved — Addressed
03/23/2021
Filed — Alteration
HEREBY FILING FOR THE LEGALIZATION OF BATHROOMS AND INSTALLATION OF GAS DRYER TO ADDRESS VIOLATIONS 35413801N 35477249L. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00490109-I1
03/23/2021
Filed — Alteration
B00490107-I1
03/17/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/23/2020
Violation issued (ECB, closed)
Unknown
12/22/2020
Violation issued (ECB, closed)
Construction
09/17/2009
Violation issued (ECB, closed)
Unknown
03/30/2009
Violation issued (ECB, closed)
Unknown
09/04/2008
Violation issued (ECB, closed)
Construction
09/04/2008
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offEZ RUNER CONSTRUCTION COR05/19/2021
DOB NOWPlumbingSigned-offEZ RUNER CONSTRUCTION COR05/12/2021
2 projects · most recent 04/30/2021
General Wiring
FiledStatusContractorScope
04/30/2021CompleteV&B ELECTRICAL CONTNG INCGeneral Wiring
04/30/2021CompleteV&B ELECTRICAL CONTNG INCGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
07/27/2021Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/23/2021Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/19/2021Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/19/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/19/2021Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
08/31/2021Fire-Resistant Penetrations and Jointsbassam (sam) rimawispecial
08/31/2021Energy Code Compliance Inspectionsbassam (sam) rimawiprogress
08/31/2021Maintenance informationbassam (sam) rimawienergy_progress
08/17/2021Fire-Resistant Penetrations and Jointsbassam (sam) rimawispecial
08/17/2021Energy Code Compliance Inspectionsbassam (sam) rimawiprogress
08/17/2021Maintenance informationbassam (sam) rimawienergy_progress
07/29/2021Maintenance informationbassam (sam) rimawienergy_progress
07/29/2021Fire-Resistant Penetrations and Jointsbassam (sam) rimawispecial
07/29/2021Energy Code Compliance Inspectionsbassam (sam) rimawiprogress
06/25/2021Energy Code Compliance Inspectionsbassam (sam) rimawiprogress
06/25/2021Maintenance informationbassam (sam) rimawienergy_progress
06/25/2021Fire-Resistant Penetrations and Jointsbassam (sam) rimawispecial
▾Documents — 29 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
09/01/2026B00490109-P1Request digital key ↗
09/01/2026B00490107-I1Request digital key ↗
08/15/2026B00490109-P2Request digital key ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications17
▸DOB NOWProgress Inspector Seal & Signature8
09/01/2026B00490109-P1Open ↗
09/01/2026B00490109-P1Open ↗
08/27/2026B00490109-P2Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
09/01/2026B00490109-P2Open ↗
09/01/2026B00490109-P3Open ↗
09/01/2026B00490109-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/01/2026B00490109-P1Open ↗
08/27/2026B00490109-P2Open ↗
08/24/2026B00490109-I1Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
09/01/2026B00490109-P1Open ↗
09/01/2026B00490107-I1Open ↗
08/15/2026B00490109-P2Open ↗
Showing 3 of 5 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/14/2026B00490109-I1Open ↗
▸Other Documents1
▸DOB NOWHPD - Completion Notice1
08/13/2026B00490107-I1Open ↗