← Back
Church, synagogue, chapel
515 ELTON STREET
BROOKLYN · BIN 3089787
💬 Discuss this project
1930Year Built
2Stories
M1Building Class
R5Zoning
8,600 sfGross Floor Area
0Units
Church, synagogue, chapel · 6,750 sf lot · 1.27 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalFire Protection
Roof3p · 1 filing · 4 docs
Floor 26p · 2 filings · 9 docs
Floor 14p · 1 filing · 4 docs
Cellar1p · 1 filing · 5 docs
1 job · most recent 12/10/2021
FiledStatusContractorScope
12/10/2021——73 heads
2 jobs · most recent 03/19/2026
General Wiring
FiledStatusContractorScope
03/19/2026Permit IssuedAMERICAN ENG ELECL SVCS IGeneral Wiring
05/01/2018CompleteWILLDAN ELECTRICAL OF NY—
Building Lifecycle
All (19)Filed (4)Permit Issued (3)Inspection (1)Objection (9)Special Inspection (2)
11/26/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/02/2024
Permit issued — Mechanical Systems
B01092665-I1-MS
09/30/2024
Permit issued — Plumbing
B01092665-S1-PL
09/19/2024
Filed — Alteration
B01092665-S1
09/19/2024
Filed — Alteration
B01092665-I1
04/06/2022
Objection raised — Inspections
04/06/2022
Objection raised — Admin
04/06/2022
Objection raised — Admin
04/06/2022
Objection raised — Scope
04/06/2022
Objection raised — Inspections
04/06/2022
Objection raised — Scope
04/06/2022
Objection raised — Structural
04/06/2022
Objection raised — Scope
04/06/2022
Objection raised — Inspections
03/29/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANTHONY VILLANO
12/10/2021
Filed — Alteration
SPRINKLER SYSTEM INSTALLATION ON CELLAR, 1ST TO 2ND FLOORS OF EXISTING RELIGIOUS INSTITUTION. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B00623058-I1
11/01/2021
Special inspection requirement — Sprinkler Systems
ANTHONY VILLANO
10/25/2021
Permit issued — General Construction
B00504840-I1-GC
05/06/2021
Filed — Alteration
INTERIOR MODIFICATIONS TO CHURCH SEATING AND CEILING. NEW PARTITIONS FOR NEW ADA TOILET AND OFFICES. REPLACE AND RELOCATE PLUMBING FIXTURES. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B00504840-I1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BULL ENTERPRISE807/08/2026
E NY 7TH DAY ADVNTIST CHURCH103/21/2026
SEVENTH DAY ADVENTIST CHURCH203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BADALY ENGINEERING PLLC209/19/2024
ACV DESIGN LTD112/10/2021
LESLIE M. GOOD ARCHITECTS105/06/2021
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TRI-STATE RENOVATIONS,INCGeneral Contractor203/21/2026
MAMC CONSULTING REPS LLCGeneral Contractor107/08/2026
L.L.G. PLBG & HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BADALY ARCHITECT PLLC7137109/19/2024
ACV DESIGN LTD3864212/10/2021
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedMAMC CONSULTING REPS LLC10/02/2024
DOB NOWPlumbingSigned-offL.L.G. PLBG & HTG INC09/30/2024
DOB NOWGeneral ConstructionPermit IssuedTRI-STATE RENOVATIONS,INC10/25/2021
BISPLISSUEDGENET PLBG AND HTG CORP01/24/2006
BISPLISSUEDGENET PLBG AND HTG CORP06/08/2005
BISFPISSUEDMASTER FIRE SYSTEMS, INC06/07/2002
BISPLISSUEDRIGID PLUMBING CONT INC07/03/2000
BISMHISSUEDNORTHSTAR CONSRT MAN INC01/07/2000
BISPLISSUEDVENTURE PLG & HTG10/29/1991
BISOTISSUEDTUNOLB CONSTR.10/04/1991
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
11/26/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
03/29/2022Fire-Resistant Penetrations and JointsANTHONY VILLANOspecial
11/01/2021Sprinkler SystemsANTHONY VILLANOspecial
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
09/01/2026B00504840-I1Request digital key ↗
08/24/2026B01092665-I1Request digital key ↗
08/24/2026B01092665-S1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature4
09/01/2026B00504840-I1Open ↗
08/24/2026B01092665-I1Open ↗
08/24/2026B01092665-S1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature1
08/22/2026B00623058-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
09/01/2026B00504840-I1Open ↗
08/13/2026B00623058-I1Open ↗
▸Approvals, Objections & Sign-offs2
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter2
08/13/2026B00504840-I1Open ↗
08/13/2026B00623058-I1Open ↗