← Back
Five to six families
754 MILLER AVENUE
BROOKLYN · BIN 3096715
💬 Discuss this project
1930Year Built
3Stories
C2Building Class
R6Zoning
4,685 sfGross Floor Area
6Units
Rent Stabilized499 Open Violations ▸FDNY Report ↗
Five to six families · Owner of record: NEIGHBORHOOD RESTORE HOUSING DEVELOPMENT FUND CORP · 2,900 sf lot · 1.62 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
RoofUnder Construction50p · 1 filing · 20 docs
Floor 3Under Construction43p · 1 filing · 20 docs
Floor 2Under Construction43p · 1 filing · 20 docs
Floor 1Under Construction43p · 1 filing · 20 docs
CellarUnder Construction46p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NEIGHBORHOOD RESTORE1307/08/2026
PROJECT EYE CONSULTANTS307/08/2026
NEIGHBORHOOD RESTORE HOUSING DEVELOPMENT FUND CORP103/22/2026
HPD303/21/2026
SHINDA MANAGEMENT CORP103/21/2026
C O SHINDA MANAGEMENT303/21/2026
NEIGHBORHOOD RESTORE HDFC203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RKTB ARCHITECTS, P.C.312/15/2025
NEW YORK ENGINEERS LLC410/17/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
DVA Advisors603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PROJECT EYE CONSULTANTS IGeneral Contractor407/08/2026
NM MECHANICAL CORPPlumbing207/08/2026
BROWN, RICHARDElectrical103/21/2026
ENGLISH, CLAUDIUSElectrical103/21/2026
GOODE, BRIANElectrical103/21/2026
ANDREW MYHRE INCElectrical103/21/2026
KAPLOWITZ BARRYElectrical103/21/2026
VIVID MECHANICHAL, LLCElectrical103/21/2026
DYNAMIC PLBNG & SPRKR CORFire Protection106/28/2026
JOE MIDDLETONElectrical103/21/2026
BARRY KAPLOWITZElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
METRIC CONSULTING AND INS1803610/17/2025
Building Lifecycle
All (162)Filed (7)Permit Issued (7)Violation (60)Inspection (10)Objection (48)Special Inspection (30)
05/05/2026
Violation issued (HPD, closed)
A
04/09/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/07/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/20/2026
Permit issued — Structural
B00943272-S1-ST
03/20/2026
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
03/10/2026
Violation issued (ECB, closed)
Construction
03/10/2026
Violation issued (ECB, closed)
Unknown
03/08/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
03/02/2026
Permit issued — Sprinklers
B00943272-S4-EW-SP
02/19/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
02/18/2026
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
02/13/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
02/13/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
02/11/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
02/10/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
01/30/2026
Permit issued — Sprinklers
B00943272-S4-EW-SP
01/29/2026
Permit issued — Construction Fence
B00943272-S6-FN
01/29/2026
Permit issued — Plumbing
B00943272-S3-PL
01/28/2026
Permit issued — General Construction
B00943272-I1-GC
01/26/2026
Permit issued — Mechanical Systems
B00943272-S2-MS
12/15/2025
Filed — Alteration
Interior and exterior renovation of existing 3-story building as shown on plans. No change to use or occupancy.
B00943272-S6
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
10/24/2025
Special inspection requirement — Maintenance information
SAMI HAJJAR P.E
10/23/2025
Objection resolved — Addressed
10/17/2025
Filed — Alteration
Interior and exterior renovation of existing 3-story building as shown on plans. No change to use or occupancy.
B00943272-S5
10/03/2025
Special inspection requirement — HVAC-R and service water heating equipment
SAMI HAJJAR P.E
10/03/2025
Special inspection requirement — HVAC-R and service water heating system controls
SAMI HAJJAR P.E
10/03/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
SAMI HAJJAR P.E
10/01/2025
Objection resolved — Addressed
09/28/2025
Special inspection requirement — Heating Systems
SAMI HAJJAR P.E
09/28/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
SAMI HAJJAR P.E
09/18/2025
Objection resolved — Addressed
09/15/2025
Objection resolved — Addressed
09/11/2025
Objection resolved — Addressed
09/03/2025
Objection resolved — Addressed
09/03/2025
Objection resolved — Addressed
09/03/2025
Objection resolved — Addressed
09/03/2025
Objection resolved — Addressed
09/03/2025
Objection resolved — Addressed
09/03/2025
Objection resolved — Addressed
09/03/2025
Objection resolved — Addressed
09/03/2025
Objection resolved — Addressed
09/03/2025
Objection resolved — Addressed
06/10/2025
Violation issued (HPD, closed)
A
02/11/2025
Objection raised — Scope
02/11/2025
Objection raised — Fire_Protection
02/11/2025
Objection raised — Fire_Protection
02/11/2025
Objection raised — Fire_Protection
02/11/2025
Objection raised — Fire_Protection
02/11/2025
Objection raised — Fire_Protection
02/10/2025
Objection raised — Energy
02/10/2025
Objection raised — Plumbing
02/10/2025
Objection raised — Plumbing
02/10/2025
Objection raised — Plumbing
02/10/2025
Objection raised — Energy
02/10/2025
Objection raised — Plumbing
02/06/2025
Filed — Alteration
Interior and exterior renovation of existing 3-story building as shown on plans. No change to use or occupancy.
B00943272-S4
02/06/2025
Filed — Alteration
Interior and exterior renovation of existing 3-story building as shown on plans. No change to use or occupancy.
B00943272-S3
02/06/2025
Filed — Alteration
Interior and exterior renovation of existing 3-story building as shown on plans. No change to use or occupancy.
B00943272-S2
01/02/2025
Objection resolved — Addressed
Latest 60 of 162 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedPROJECT EYE CONSULTANTS I03/20/2026
DOB NOWSprinklersPermit IssuedCITYWIDE PLBG, HTG &SPRKL03/02/2026
DOB NOWSprinklersPermit IssuedNM MECHANICAL CORP01/30/2026
DOB NOWConstruction FencePermit IssuedPROJECT EYE CONSULTANTS I01/29/2026
DOB NOWPlumbingPermit IssuedNM MECHANICAL CORP01/29/2026
DOB NOWGeneral ConstructionPermit IssuedPROJECT EYE CONSULTANTS I01/28/2026
DOB NOWMechanical SystemsPermit IssuedPROJECT EYE CONSULTANTS I01/26/2026
BISOTISSUEDTHE KINGSLAND GROUP INC02/06/2002
BISOTISSUEDPENTA RESTORATION CORP09/08/2000
1 project · most recent 12/15/2025
Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
12/15/2025Permit IssuedPROJECT EYE CONSULTANTS IHeating Systems, Ventilation Systems
Heating
Neptronic DF CF00H 11 kW · Ductwork ×2
Marley CWH1202DSF 2 kW · Electric Heater ×1
Peerless 63-06 288,000 BTU · Boiler ×1
Ventilation
Greenheck USF-06-B5 150 CFM · Exhaust Fan ×4
USF-06 460 CFM · Exhaust Fan ×2
USF-08-B5 610 CFM · Exhaust Fan ×1
1 project · most recent 12/15/2025
Sprinkler System
FiledStatusContractorScope
12/15/2025Permit IssuedDYNAMIC PLBNG & SPRKR CORSprinkler System
1 project · most recent 12/15/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
12/15/2025Permit IssuedNM MECHANICAL CORPGas, Storm, Water/Sanitary
1 project · most recent 03/04/2026
General Wiring
FiledStatusContractorScope
03/04/2026Permit IssuedGRAMERCY ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
04/09/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/07/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/20/2026Pass-Final PL - Up to 9 Requested FloorsPassView ↗
03/08/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
02/19/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
02/18/2026Pass-Final PL - UndergroundPassView ↗
02/13/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
02/13/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
02/11/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
02/10/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 37
DateRequirementInspectorRole
10/24/2025Maintenance informationSAMI HAJJAR P.Eenergy_progress
10/03/2025HVAC-R and service water heating equipmentSAMI HAJJAR P.Eenergy_progress
10/03/2025HVAC-R and service water heating system controlsSAMI HAJJAR P.Eenergy_progress
10/03/2025HVAC-R and service water piping design and insulationSAMI HAJJAR P.Eenergy_progress
09/28/2025Heating SystemsSAMI HAJJAR P.Especial
09/28/2025Fire-Resistant Penetrations and JointsSAMI HAJJAR P.Especial
10/30/2024Duct leakage testing, insulation and designSAMI HAJJAR P.Eenergy_progress
10/30/2024Electrical motors and elevatorsSAMI HAJJAR P.Eenergy_progress
10/30/2024Maintenance informationSAMI HAJJAR P.Eenergy_progress
10/30/2024HVAC-R and service water heating equipmentSAMI HAJJAR P.Eenergy_progress
10/30/2024Exterior lighting powerSAMI HAJJAR P.Eenergy_progress
10/30/2024Interior lighting powerSAMI HAJJAR P.Eenergy_progress
10/30/2024Shutoff dampersSAMI HAJJAR P.Eenergy_progress
10/30/2024HVAC-R and service water heating system controlsSAMI HAJJAR P.Eenergy_progress
10/30/2024Lighting in dwelling unitsSAMI HAJJAR P.Eenergy_progress
10/30/2024Fire-Resistant Penetrations and JointsSAMI HAJJAR P.Especial
10/30/2024MeteringSAMI HAJJAR P.Eenergy_progress
10/30/2024Post-installed AnchorsSAMI HAJJAR P.Especial
10/30/2024Fire-Resistant Penetrations and JointsSAMI HAJJAR P.Especial
10/30/2024Heating SystemsSAMI HAJJAR P.Especial
10/30/2024HVAC-R and service water piping design and insulationSAMI HAJJAR P.Eenergy_progress
10/30/2024Lighting controlsSAMI HAJJAR P.Eenergy_progress
08/29/2024Structural Stability – Alterations of existing buildingsSAMI HAJJAR P.Especial
08/29/2024Structural Wood FrameSAMI HAJJAR P.Eprogress
08/29/2024Wood – Seismic Resistance—special
Latest 25 of 37.
▾Documents — 37 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/22/2026B00943272-S3Request digital key ↗
08/22/2026B00943272-S2Request digital key ↗
08/22/2026B00943272-S1Request digital key ↗
Showing 3 of 7 on file for this type
▸Seals & Professional Certifications19
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/22/2026B00943272-S3Open ↗
08/22/2026B00943272-S2Open ↗
08/22/2026B00943272-S6Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProgress Inspector Seal & Signature7
09/02/2026B00943272-S5Open ↗
08/28/2026B00943272-I1Open ↗
08/28/2026B00943272-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/02/2026B00943272-S5Open ↗
08/28/2026B00943272-I1Open ↗
08/28/2026B00943272-S1Open ↗
Showing 3 of 5 on file for this type
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form5
08/22/2026B00943272-S3Open ↗
08/22/2026B00943272-S2Open ↗
08/22/2026B00943272-S1Open ↗
Showing 3 of 5 on file for this type
▸Approvals, Objections & Sign-offs6
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter6
08/13/2026B00943272-I1Open ↗
08/13/2026B00943272-S5Open ↗
08/13/2026B00943272-S2Open ↗
Showing 3 of 6 on file for this type