← Back
Predominantly retail with other uses
897 FLATBUSH AVENUE
BROOKLYN · BIN 3117221
💬 Discuss this project
1930Year Built
3Stories
K4Building Class
C4-4AZoning
9,500 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Predominantly retail with other uses · Owner of record: 897 FLATBUSH REALTY LLC · 4,800 sf lot · 1.98 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingGeneral
Roof5p · 1 filing · 7 docs
Floor 21p · 1 filing · 12 docs
Floor 118p · 5 filings · 20 docs
Mezzanine1p · 1 filing · 12 docs
Cellar1p · 1 filing · 12 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MELROSE2107/08/2026
OWNERS REP707/08/2026
897 FLATBUSH REALTY303/22/2026
CASTRO REALTY603/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PAUL PERDEK, PROF. ENG. PLLC411/29/2022
C3D ARCHITECTURE PLLC206/13/2022
C2B ARCHITECTS PC402/10/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
PENN SOUTH CAPITAL MANAGEMENT LLC203/21/2026
AE DESIGN SOLUTION803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ALCHEMY DEVELOPMENTGeneral Contractor507/08/2026
CORE SCAFFOLD SYSTEMS INC.General Contractor407/08/2026
SCAMPA CONTRACTING, CORPGeneral Contractor203/21/2026
A&H EXPRESS PLBG&HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
RAYMOND HO ARCHITECT, PLL1654206/13/2022
CDG ARCHITECTS LLC /DBA:1327302/10/2022
Building Lifecycle
All (45)Filed (10)Permit Issued (7)Signed Off (2)Violation (3)Inspection (2)Special Inspection (21)
03/01/2023
Signed off — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B08035170-I1
03/01/2023
Signed off — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B08035177-I1
12/24/2022
Violation issued (ECB, closed)
Construction
11/29/2022
Filed — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B08035177-P1
11/18/2022
Filed — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B08035170-P1
11/11/2022
Permit issued — Supported Scaffold
B08035177-I1-SF
11/11/2022
Permit issued — Sidewalk Shed
B08035170-I1-SH
11/10/2022
Filed — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B08035170-I1
11/10/2022
Filed — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B08035177-I1
06/21/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
06/14/2022
Special inspection requirement — Fenestration areas
Paul Freitas
06/14/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
PING MAN HO
06/14/2022
Special inspection requirement — Fire-Resistance Rated Construction
Paul Freitas
06/14/2022
Special inspection requirement — Final
Paul Freitas
06/14/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
Paul Freitas
06/13/2022
Filed — Alteration
B00661216-P1
04/27/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/19/2022
Permit issued — Plumbing
B00663539-I1-PL
02/14/2022
Permit issued — General Construction
B00663538-I1-GC
02/14/2022
Permit issued — General Construction
B00664059-I1-GC
02/10/2022
Filed — Alteration
New storefront on the existing opening
B00664059-I1
02/10/2022
Filed — Alteration
HVAC modifications as per plans
B00663540-I1
02/10/2022
Filed — Alteration
plumbing fit out new piping and fixtures
B00663539-I1
02/10/2022
Filed — Alteration
interior renovation of commercial space. New non-load bearing partition, new wall floor, and ceiling finishes. No change in use egress and occupancy under this application
B00663538-I1
02/10/2022
Permit issued — Mechanical Systems
B00663540-I1-MS
02/08/2022
Permit issued — General Construction
B00661216-I1-GC
01/19/2022
Filed — Alteration
B00661216-I1
01/16/2022
Special inspection requirement — HVAC-R and service water heating equipment
Yongho Kim
01/16/2022
Special inspection requirement — Maintenance information
Yongho Kim
01/16/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Yongho Kim
01/16/2022
Special inspection requirement — HVAC-R and service water heating system controls
Yongho Kim
01/16/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Yongho Kim
01/16/2022
Special inspection requirement — HVAC-R and service water heating equipment
Yongho Kim
01/16/2022
Special inspection requirement — Maintenance information
Yongho Kim
01/16/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Yongho Kim
01/16/2022
Special inspection requirement — Final
Yongho Kim
01/16/2022
Special inspection requirement — Lighting controls
Yongho Kim
01/16/2022
Special inspection requirement — Mechanical Systems
Yongho Kim
01/16/2022
Special inspection requirement — Interior lighting power
Yongho Kim
01/16/2022
Special inspection requirement — Final
Yongho Kim
01/16/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Yongho Kim
01/16/2022
Special inspection requirement — HVAC-R and service water heating system controls
Yongho Kim
01/16/2022
Special inspection requirement — Shutoff dampers
Yongho Kim
08/11/1995
Violation issued (FDNY_NOV, closed)
11/07/1988
Violation issued (FDNY_NOV, closed)
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSupported ScaffoldSigned-offCORE SCAFFOLD SYSTEMS INC11/11/2022
DOB NOWSidewalk ShedSigned-offCORE SCAFFOLD SYSTEMS INC11/11/2022
DOB NOWPlumbingSigned-offA&H EXPRESS PLBG&HTG CORP03/19/2022
DOB NOWGeneral ConstructionPermit IssuedALCHEMY DEVELOPMENT02/14/2022
DOB NOWGeneral ConstructionPermit IssuedALCHEMY DEVELOPMENT02/14/2022
DOB NOWMechanical SystemsPermit IssuedALCHEMY DEVELOPMENT02/10/2022
DOB NOWGeneral ConstructionPermit IssuedSCAMPA CONTRACTING, CORP02/08/2022
BIS—ISSUEDSUPER NEON LIGHTS CO.INC.04/16/1996
BISEQISSUEDB&W CONTRACTING INC./GALIL CONTR03/29/1996
BISEQISSUEDB&W CONTRACTING INC./GALIL CONTR03/29/1996
BISPLISSUEDBAUER MECHANCIAL LLC03/04/1996
BISMHISSUEDB-W CONSTRACTING INC02/07/1996
BISEQISSUEDB-W CONSTRACTING INC02/07/1996
BISOTISSUEDPOWER COOLING INC11/06/1991
1 project · most recent 02/10/2022
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
02/10/2022Permit IssuedALCHEMY DEVELOPMENTAir Conditioning Systems
Cooling
Mitsubishi Electric PUMY-P48NKMU3 4 tons · Vrf Outdoor ×2
PUMY-P60NKMU3 5 tons · Vrf Outdoor ×1
1 project · most recent 02/10/2022
Water/Sanitary
FiledStatusContractorScope
02/10/2022Signed-offA&H EXPRESS PLBG&HTG CORPWater/Sanitary
4 projects · most recent 07/12/2024
General Wiring
FiledStatusContractorScope
07/12/2024Permit IssuedT.M.T ELECTRIC INC4 meters, 3 new_meters
11/04/2022CompleteSOLAS ELECTRICAL CORP—
09/09/2022Permit IssuedGEMINI ELECTRIC CO., INC.General Wiring
07/26/2022Permit IssuedDELTA POWER ELECTRICALGeneral Wiring
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
06/21/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/27/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 21
DateRequirementInspectorRole
06/14/2022Fenestration areasPaul Freitasenergy_progress
06/14/2022Fire-Resistant Penetrations and JointsPING MAN HOspecial
06/14/2022Fire-Resistance Rated ConstructionPaul Freitasprogress
06/14/2022FinalPaul Freitasprogress
06/14/2022Fenestration and door U-factor and product ratingsPaul Freitasenergy_progress
01/16/2022HVAC-R and service water heating equipmentYongho Kimenergy_progress
01/16/2022Maintenance informationYongho Kimenergy_progress
01/16/2022Fire-Resistant Penetrations and JointsYongho Kimspecial
01/16/2022HVAC-R and service water heating system controlsYongho Kimenergy_progress
01/16/2022HVAC-R and service water piping design and insulationYongho Kimenergy_progress
01/16/2022HVAC-R and service water heating equipmentYongho Kimenergy_progress
01/16/2022Maintenance informationYongho Kimenergy_progress
01/16/2022Fire-Resistant Penetrations and JointsYongho Kimspecial
01/16/2022FinalYongho Kimprogress
01/16/2022Lighting controlsYongho Kimenergy_progress
01/16/2022Mechanical SystemsYongho Kimspecial
01/16/2022Interior lighting powerYongho Kimenergy_progress
01/16/2022FinalYongho Kimprogress
01/16/2022HVAC-R and service water piping design and insulationYongho Kimenergy_progress
01/16/2022HVAC-R and service water heating system controlsYongho Kimenergy_progress
01/16/2022Shutoff dampersYongho Kimenergy_progress
▾Documents — 50 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/31/2026B00663540-I1Request digital key ↗
08/31/2026B00663538-I1Request digital key ↗
08/31/2026B00663539-I1Request digital key ↗
Showing 3 of 10 on file for this type
▸Applications & Permits1
▸BISPLAN / WORK APPROVAL APPLICATION1
02/17/2010320115754Open ↗
▸Seals & Professional Certifications24
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/31/2026B00663538-I1Open ↗
08/31/2026B00664059-I1Open ↗
08/29/2026B00661216-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWProgress Inspector Seal & Signature9
09/01/2026B00661216-I1Open ↗
09/01/2026B00661216-I1Open ↗
09/01/2026B00661216-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/01/2026B00661216-I1Open ↗
09/01/2026B00663539-I1Open ↗
08/23/2026B00663538-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
02/17/2010320115754Open ↗
▸Environmental & Asbestos12
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/31/2026B00663538-I1Open ↗
08/31/2026B00664059-I1Open ↗
08/29/2026B00661216-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWOER: Notice to Proceed5
08/13/2026B00663539-I1Open ↗
08/13/2026B00664059-I1Open ↗
08/13/2026B00663538-I1Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
02/17/2010320115754Open ↗
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
02/17/2010320115754Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
02/17/2010320115754Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
02/17/2010320115754Open ↗