Locations of Work
ArchitectureElectricalMechanicalPlumbing
Roof2p · 2 filings · 8 docs
Floor 218p · 3 filings · 20 docs
Floor 112p · 1 filing · 14 docs
Cellar1p · 1 filing · 4 docs
Sub-Basement12p · 1 filing · 14 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
VALENCE8807/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BENDIX ENGINEERING, P.C.304/03/2024
BEN HERZOG ARCHITECT PC104/11/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ANZALONE ARCHITECTURE803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
K & B HVAC LLCGeneral Contractor303/21/2026
ADVANCED REMODELING SOLUGeneral Contractor107/08/2026
ORBIT PLBG & HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BENDIX ENGINEERING, P.C.4293304/03/2024
BEN HERZOG ARCHITECT, PC1544104/11/2023
Building Lifecycle
All (38)Filed (4)Permit Issued (3)Signed Off (2)Inspection (7)Objection (10)Special Inspection (12)
11/06/2025
Signed off — Alteration
B00828328-I1
04/16/2025
Permit issued — Mechanical Systems
B00828328-I1-MS
04/11/2025
Signed off — Alteration
GENERAL CONSTRUCTION ALTERATIONS TO EXISTING 1-FAMILY RESIDENCE. DEMOLISH AND CONSTRUCT NON-STRUCTURAL PARTITIONS, DOORS, WINDOWS AND FINISHES. NO CHANGE TO USE, EGRESS AND OCCUPANCY.
B00828302-I1
11/15/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/05/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
05/31/2024
Inspection — No Access-Final PL - Up to 3 Requested Floors
No Access
View inspection ↗
04/29/2024
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
04/22/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/18/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/09/2024
Permit issued — Plumbing
B00828341-I1-PL
04/08/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Matthew Bendix
04/08/2024
Special inspection requirement — Energy Code Compliance Inspections
Matthew Bendix
04/08/2024
Special inspection requirement — Maintenance information
Matthew Bendix
04/08/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Matthew Bendix
04/08/2024
Special inspection requirement — HVAC-R and service water heating system controls
Matthew Bendix
04/08/2024
Special inspection requirement — HVAC-R and service water heating equipment
Matthew Bendix
04/05/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/03/2024
Filed — Alteration
PLUMBING WORK FILED IN CONJUNCTION WITH ALTERATION TO ONE-FAMILY RESIDENCE. INSTALL PLUMBING FIXTURES AND RELATED PIPING. REMOVE EXISTING GAS FURNACE, RELOCATE GAS METER AND RELOCATE GAS RANGE.
B00828341-P1
03/15/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Matthew Bendix
03/15/2024
Special inspection requirement — Energy Code Compliance Inspections
Matthew Bendix
03/15/2024
Special inspection requirement — Maintenance information
Matthew Bendix
03/15/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Matthew Bendix
03/15/2024
Special inspection requirement — HVAC-R and service water heating equipment
Matthew Bendix
03/15/2024
Special inspection requirement — HVAC-R and service water heating system controls
Matthew Bendix
10/26/2023
Permit issued — General Construction
B00828302-I1-GC
08/21/2023
Objection resolved — Addressed
08/21/2023
Objection resolved — Addressed
06/17/2023
Objection resolved — Addressed
06/17/2023
Objection resolved — Addressed
05/23/2023
Objection raised — Other
05/23/2023
Objection raised — Other
05/23/2023
Objection raised — Admin
05/23/2023
Objection raised — Other
05/22/2023
Filed — Alteration
PLUMBING WORK FILED IN CONJUNCTION WITH ALTERATION TO ONE-FAMILY RESIDENCE. INSTALL PLUMBING FIXTURES AND RELATED PIPING. REMOVE EXISTING GAS FURNACE, RELOCATE GAS METER AND RELOCATE GAS RANGE.
B00828341-I1
05/19/2023
Filed — Alteration
B00828328-I1
04/13/2023
Objection raised — Scope
04/13/2023
Objection resolved — Addressed
04/11/2023
Filed — Alteration
GENERAL CONSTRUCTION ALTERATIONS TO EXISTING 1-FAMILY RESIDENCE. DEMOLISH AND CONSTRUCT NON-STRUCTURAL PARTITIONS, DOORS, WINDOWS AND FINISHES. NO CHANGE TO USE, EGRESS AND OCCUPANCY.
B00828302-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offK & B HVAC LLC04/16/2025
DOB NOWPlumbingPermit IssuedORBIT PLBG & HTG INC04/09/2024
DOB NOWGeneral ConstructionSigned-offADVANCED REMODELING SOLU10/26/2023
1 project · most recent 04/03/2024
Gas Water/Sanitary
FiledStatusContractorScope
04/03/2024Permit IssuedORBIT PLBG & HTG INCGas, Water/Sanitary
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
11/15/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/05/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
05/31/2024No Access-Final PL - Up to 3 Requested FloorsNo AccessView ↗
04/29/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
04/22/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/18/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
04/05/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
04/08/2024Fire-Resistant Penetrations and JointsMatthew Bendixspecial
04/08/2024Energy Code Compliance InspectionsMatthew Bendixprogress
04/08/2024Maintenance informationMatthew Bendixenergy_progress
04/08/2024HVAC-R and service water piping design and insulationMatthew Bendixenergy_progress
04/08/2024HVAC-R and service water heating system controlsMatthew Bendixenergy_progress
04/08/2024HVAC-R and service water heating equipmentMatthew Bendixenergy_progress
03/15/2024Fire-Resistant Penetrations and JointsMatthew Bendixspecial
03/15/2024Energy Code Compliance InspectionsMatthew Bendixprogress
03/15/2024Maintenance informationMatthew Bendixenergy_progress
03/15/2024HVAC-R and service water piping design and insulationMatthew Bendixenergy_progress
03/15/2024HVAC-R and service water heating equipmentMatthew Bendixenergy_progress
03/15/2024HVAC-R and service water heating system controlsMatthew Bendixenergy_progress
▾Documents — 22 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/27/2026B00828302-I1Request digital key ↗
08/27/2026B00828328-I1Request digital key ↗
08/25/2026B00828341-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits4
▸DOB NOWLPC Approval/Permit4
08/15/2026B00828341-I1Open ↗
08/13/2026B00828302-I1Open ↗
08/13/2026B00828328-I1Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications10
▸DOB NOWProgress Inspector Seal & Signature4
09/01/2026B00828341-I1Open ↗
09/01/2026B00828341-I1Open ↗
08/28/2026B00828341-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/27/2026B00828302-I1Open ↗
08/27/2026B00828328-I1Open ↗
08/25/2026B00828341-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026B00828341-I1Open ↗
08/28/2026B00828341-P1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/27/2026B00828328-I1Open ↗
08/15/2026B00828341-I1Open ↗
08/13/2026B00828341-P1Open ↗
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
08/27/2026B00828302-I1Open ↗