| Owner | Filings | Most Recent |
|---|---|---|
| 1377 ROGERS HOLDINGS, LLC. | 7 | 03/21/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 09/26/2024 | $600K | — | Private party → 1377 ROGERS HOLDINGS LLC | $147/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| CELIN MUNOZ CONSULTING ENGINEER, PC | 2 | 07/24/2025 |
| OPERA STUDIO ARCHITECTURE, LLC | 1 | 02/14/2025 |
| Representative | Filings | Most Recent |
|---|---|---|
| OPERA STUDIO ARCHITECTURE LLC | 4 | 03/21/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| BIS | PL | ISSUED | JOHNNY'S P&H CONTRAC INC | 06/08/2004 |
| BIS | PL | ISSUED | G.A PLBG,HTG,SPR INC | 04/30/2003 |
| BIS | — | ISSUED | AARON CHEUNG PE PC | 03/11/2002 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 07/24/2025 | — | — | Heating and Air Conditioning Systems, Ventilation Systems | Heat / Cool Mitsubishi Electric MXZ-SM36NAM2-U1 36,000 BTU · Condensing Unit ×9 MXZ-SM48NAM2-U1 48,000 BTU · Condensing Unit ×4 MUZ-GS12NAHZ 9,000 BTU · Condensing Unit ×1 Ventilation |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/24/2025 | — | — | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/24/2025 | — | — | Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/24/2025 | — | — | Steel, Concrete, Masonry |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 07/23/2025 | Structural Steel - Details | — | special |
| 07/10/2025 | Masonry | — | special |
| 07/10/2025 | Structural Cold-Formed Steel | — | special |
| 07/10/2025 | Final | — | progress |
| 07/10/2025 | Structural Stability – Alterations of existing buildings | — | special |
| 07/10/2025 | Concrete - Cast-In-Place | — | special |
| 07/10/2025 | Structural Stability – Alterations of existing buildings | — | special |
| 07/10/2025 | Final | — | progress |
| 07/10/2025 | Footing and Foundation | — | progress |
| 02/05/2025 | Fenestration areas | — | energy_progress |
| 02/05/2025 | Fenestration air leakage | — | energy_progress |
| 02/05/2025 | Exterior lighting power | — | energy_progress |
| 02/05/2025 | Insulation placement and R values | — | energy_progress |
| 02/05/2025 | Lighting controls | — | energy_progress |
| 02/05/2025 | Lighting in dwelling units | — | energy_progress |
| 02/05/2025 | Metering | — | energy_progress |
| 02/05/2025 | Maintenance information | — | energy_progress |
| 02/05/2025 | Fenestration and door U-factor and product ratings | — | energy_progress |
| 02/05/2025 | Interior lighting power | — | energy_progress |
| 02/05/2025 | Fire-Resistant Penetrations and Joints | — | special |
| 02/05/2025 | Air barrier - visual inspection | — | energy_progress |
| 02/01/2025 | Structural Stability – Alterations of existing buildings | — | special |