← Back
Two stories - detached, small or mid-size
342 EAST 5 STREET
BROOKLYN · BIN 3124666
💬 Discuss this project
1920Year Built
2.75Stories
A1Building Class
R5Zoning
1,983 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 2,300 sf lot · 0.86 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ASR ENGINEERING PC109/07/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ACE GROUP NY CORPGeneral Contractor109/07/2026
Building Lifecycle
All (14)Filed (1)Permit Issued (1)Objection (1)Special Inspection (11)
09/15/2026
Objection raised — Other
09/07/2026
Filed — Alteration
FILING FOR INTERIOR RENOVATION OF EXISTING ONE (1) FAMILY DWELLING UNIT. REPAIR PARTITION WALLS AS NEEDED, SAND, PRIME AND PAINT ALL WALLS,CEILINGS, DOORS AND FRAMES, NEW PARTITION WALLS, NEW FINISH FLOORING, NEW INTERIOR DOORS, NEW CERAMIC TILES&KITCHEN
B01456455-I1
09/06/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
09/06/2026
Special inspection requirement — Energy Code Compliance Inspections
09/06/2026
Special inspection requirement — Fire-Resistance Rated Construction
09/06/2026
Special inspection requirement — Fenestration air leakage
09/06/2026
Special inspection requirement — Fenestration areas
09/06/2026
Special inspection requirement — Interior lighting power
09/06/2026
Special inspection requirement — Permanent certificate
09/06/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
09/06/2026
Special inspection requirement — Insulation placement and R values
09/06/2026
Special inspection requirement — Air barrier - visual inspection
09/06/2026
Special inspection requirement — Maintenance information
09/01/2026
Permit issued — Construction Fence
B01452001-I1-FN
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedACE GROUP NY CORP09/01/2026
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
09/06/2026Fire-Resistant Penetrations and Joints—special
09/06/2026Energy Code Compliance Inspections—progress
09/06/2026Fire-Resistance Rated Construction—progress
09/06/2026Fenestration air leakage—energy_progress
09/06/2026Fenestration areas—energy_progress
09/06/2026Interior lighting power—energy_progress
09/06/2026Permanent certificate—energy_progress
09/06/2026Fenestration and door U-factor and product ratings—energy_progress
09/06/2026Insulation placement and R values—energy_progress
09/06/2026Air barrier - visual inspection—energy_progress
09/06/2026Maintenance information—energy_progress
▾Documents — 2 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
09/22/2026B01456455-I1Request digital key ↗
▸Seals & Professional Certifications1
▸DOB NOWDPL-1: Design Professional Seal & Signature1
09/22/2026B01456455-I1Open ↗