← Back
Two family brick
6810 16 AVENUE
BROOKLYN · BIN 3134860
💬 Discuss this project
1910Year Built
2Stories
B1Building Class
R5Zoning
2,040 sfGross Floor Area
2Units
27 Open Violations ▸FDNY Report ↗
Two family brick · 2,000 sf lot · 1.02 FAR built · Flood zone X
Locations of Work
Plumbing
Floor 21p · 1 filing · 9 docs
Floor 1
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/24/2025$1.2M—— → —$600/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ADEL SAGEER ARCHITECT, PLLC403/11/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MILLSTONE CONSTRUC LLCGeneral Contractor107/08/2026
THOMAS F. CASH & SONS INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ZHENG & ASSOCIATES LLC7330403/11/2026
Building Lifecycle
All (54)Filed (4)Permit Issued (2)Signed Off (2)Violation (27)Inspection (9)Special Inspection (10)
08/18/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
05/26/2026
Signed off — Alteration
INSTALL PLUMBING FIXTURES FOR EXISTING TWO FAMILY DWELLING UNITS. NO CHANGE IN USE OF EGRESS & OCCUPANCY.
B01318028-I1
05/15/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
05/04/2026
Signed off — Alteration
INTERIOR RENOVATION FOR EXISTING TWO FAMILY DWELLING UNITS. NO CHANGE IN USE OF EGRESS & OCCUPANCY.
B01318024-I1
03/30/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/12/2026
Special inspection requirement — Lighting in dwelling units
Jinfar Liu
03/12/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jinfar Liu
03/12/2026
Special inspection requirement — Final
Jinfar Liu
03/12/2026
Special inspection requirement — Energy Code Compliance Inspections
Jinfar Liu
03/12/2026
Special inspection requirement — Metering
Jinfar Liu
03/11/2026
Filed — Alteration
INSTALL PLUMBING FIXTURES FOR EXISTING TWO FAMILY DWELLING UNITS. NO CHANGE IN USE OF EGRESS & OCCUPANCY.
B01318028-P1
03/11/2026
Filed — Alteration
INTERIOR RENOVATION FOR EXISTING TWO FAMILY DWELLING UNITS. NO CHANGE IN USE OF EGRESS & OCCUPANCY.
B01318024-P1
03/09/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jinfar Liu
03/09/2026
Special inspection requirement — Energy Code Compliance Inspections
Jinfar Liu
03/09/2026
Special inspection requirement — HVAC-R and service water heating equipment
Jinfar Liu
03/09/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Jinfar Liu
03/09/2026
Special inspection requirement — HVAC-R and service water heating system controls
Jinfar Liu
01/28/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/14/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
12/19/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/19/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
12/17/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
12/08/2025
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
11/18/2025
Permit issued — Plumbing
B01318028-I1-PL
11/17/2025
Permit issued — General Construction
B01318024-I1-GC
11/14/2025
Filed — Alteration
INSTALL PLUMBING FIXTURES FOR EXISTING TWO FAMILY DWELLING UNITS. NO CHANGE IN USE OF EGRESS & OCCUPANCY.
B01318028-I1
11/14/2025
Filed — Alteration
INTERIOR RENOVATION FOR EXISTING TWO FAMILY DWELLING UNITS. NO CHANGE IN USE OF EGRESS & OCCUPANCY.
B01318024-I1
03/10/2025
Violation issued (HPD, open)
I
03/09/2025
Violation issued (HPD, open)
C
03/09/2025
Violation issued (HPD, open)
A
03/09/2025
Violation issued (HPD, open)
A
03/09/2025
Violation issued (HPD, open)
B
03/09/2025
Violation issued (HPD, open)
B
03/09/2025
Violation issued (HPD, open)
B
03/09/2025
Violation issued (HPD, open)
B
03/09/2025
Violation issued (HPD, open)
B
03/09/2025
Violation issued (HPD, open)
B
03/09/2025
Violation issued (HPD, open)
A
03/09/2025
Violation issued (HPD, open)
A
03/09/2025
Violation issued (HPD, open)
C
03/09/2025
Violation issued (HPD, open)
B
03/09/2025
Violation issued (HPD, open)
B
03/09/2025
Violation issued (HPD, open)
B
03/09/2025
Violation issued (HPD, open)
A
03/09/2025
Violation issued (HPD, open)
C
03/09/2025
Violation issued (HPD, open)
C
03/09/2025
Violation issued (HPD, open)
A
03/09/2025
Violation issued (HPD, open)
C
03/09/2025
Violation issued (HPD, open)
C
03/09/2025
Violation issued (HPD, open)
C
03/09/2025
Violation issued (HPD, open)
B
03/09/2025
Violation issued (HPD, open)
C
03/09/2025
Violation issued (HPD, open)
C
03/09/2025
Violation issued (HPD, open)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offTHOMAS F. CASH & SONS INC11/18/2025
DOB NOWGeneral ConstructionSigned-offMILLSTONE CONSTRUC LLC11/17/2025
1 project · most recent 03/11/2026
Gas Water/Sanitary
FiledStatusContractorScope
03/11/2026Signed-offTHOMAS F. CASH & SONS INCGas, Water/Sanitary
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
08/18/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
05/15/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
03/30/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/28/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/14/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/19/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/19/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
12/17/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
12/08/2025Pass-Final PL - UndergroundPassView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
03/12/2026Lighting in dwelling unitsJinfar Liuenergy_progress
03/12/2026Fire-Resistant Penetrations and JointsJinfar Liuspecial
03/12/2026FinalJinfar Liuprogress
03/12/2026Energy Code Compliance InspectionsJinfar Liuprogress
03/12/2026MeteringJinfar Liuenergy_progress
03/09/2026Fire-Resistant Penetrations and JointsJinfar Liuspecial
03/09/2026Energy Code Compliance InspectionsJinfar Liuprogress
03/09/2026HVAC-R and service water heating equipmentJinfar Liuenergy_progress
03/09/2026HVAC-R and service water piping design and insulationJinfar Liuenergy_progress
03/09/2026HVAC-R and service water heating system controlsJinfar Liuenergy_progress
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/18/2026B01318028-P1Request digital key ↗
08/18/2026B01318028-I1Request digital key ↗
08/18/2026B01318024-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/13/2026B01318024-P1Open ↗
08/13/2026B01318028-P1Open ↗
08/13/2026B01318028-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/01/2026B01318028-P1Open ↗
09/01/2026B01318028-P1Open ↗
09/01/2026B01318024-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026B01318028-P1Open ↗
09/01/2026B01318024-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/13/2026B01318024-I1Open ↗
08/13/2026B01318028-P1Open ↗
08/13/2026B01318028-I1Open ↗
Showing 3 of 4 on file for this type