← Back
Primarily 2 family with 1 store or office
6810 20 AVENUE
BROOKLYN · BIN 3135042
💬 Discuss this project
1931Year Built
2Stories
S2Building Class
R5Zoning
2,560 sfGross Floor Area
3Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Primarily 2 family with 1 store or office · 2,000 sf lot · 1.28 FAR built · Flood zone X
Locations of Work
Architecture
Floor 14p · 1 filing · 14 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NSC ARCHITECTURE, PC201/02/2025
LEON SKVIRSKY PE106/20/2018
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BUILDING BROTHERS203/21/2026
KC EXPEDITING INC403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CONTROL PLBG & HTG INCPlumbing507/08/2026
J.B.I. CONSTRUCTION GROUPGeneral Contractor303/21/2026
VINCENZO NAPOLITANOElectrical103/21/2026
PAUL SIGNSScaffold107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NSC ARCHITECTURE PC2016201/02/2025
Building Lifecycle
All (20)Filed (3)Permit Issued (3)Signed Off (1)Violation (10)Inspection (3)
03/19/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/18/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/13/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
02/10/2025
Permit issued — Plumbing
B01162039-S1-PL
01/10/2025
Permit issued — General Construction
B01162039-I1-GC
01/02/2025
Filed — Alteration
Propose interior renovation of an existing day care facility at 1st floor. No change to use, egress or occupancy.
B01162039-I1
01/02/2025
Filed — Alteration
Propose interior renovation of an existing day care facility at 1st floor. No change to use, egress or occupancy.
B01162039-S1
07/05/2018
Signed off — Alteration
B00049406-I1
06/21/2018
Permit issued — Sign
B00049406-I1-SG
06/20/2018
Filed — Alteration
B00049406-I1
03/23/2018
Violation issued (ECB, closed)
Construction
10/04/2016
Violation issued (ECB, closed)
Construction
11/16/2009
Violation issued (DOB, closed)
VW*-VIOLATION - WORK W/O PERMIT DISMISSED
01/06/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/27/2001
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/16/1999
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/16/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/29/1995
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/11/1991
Violation issued (ECB, closed)
Boilers
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offCONTROL PLBG & HTG INC02/10/2025
DOB NOWGeneral ConstructionPermit IssuedJ.B.I. CONSTRUCTION GROUP01/10/2025
DOB NOWSignSigned-offPAUL SIGNS, INC06/21/2018
BISOTISSUEDCITY SIGNS INC05/22/2018
BISPLISSUEDA.G.M. P & H INC04/28/2010
BISOTISSUEDN N F ENTERPRISES INC04/21/2010
BIS—ISSUEDHOMEOWNER04/05/2010
BISFBISSUEDBAYTERMINALS OF ROCKAWAY03/27/2003
BISBLISSUEDBAYTERMINALS OF ROCKAWAY07/19/2002
1 project · most recent 01/02/2025
Water/Sanitary
FiledStatusContractorScope
01/02/2025Signed-offCONTROL PLBG & HTG INCWater/Sanitary
2 projects · most recent 02/12/2025
General Wiring
FiledStatusContractorScope
02/12/2025CompleteNAPSTAR ELECTRIC INCGeneral Wiring
04/04/2018CompletePRO ELECTRIC CORP.—
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
03/19/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/18/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/13/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
01/02/2025Fire-Resistant Penetrations and JointsNicholas SCIRE-CHIANETTAspecial
01/02/2025Tenant Protection Plan ComplianceNicholas SCIRE-CHIANETTAspecial
01/02/2025Energy Code Compliance InspectionsNicholas SCIRE-CHIANETTAprogress
01/02/2025FinalNicholas SCIRE-CHIANETTAprogress
01/02/2025Lighting controlsNicholas SCIRE-CHIANETTAenergy_progress
01/02/2025Interior lighting powerNicholas SCIRE-CHIANETTAenergy_progress
01/02/2025Fire-Resistant Penetrations and JointsNicholas SCIRE-CHIANETTAspecial
01/02/2025Tenant Protection Plan ComplianceNicholas SCIRE-CHIANETTAspecial
▾Documents — 65 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
09/03/2026B00049406-I1Request digital key ↗
08/23/2026B01162039-I1Request digital key ↗
08/23/2026B01162039-S1Request digital key ↗
▸Applications & Permits9
▸BISPLAN / WORK APPROVAL APPLICATION5
05/15/2018321755310Open ↗
03/01/2010320116888Open ↗
02/10/2010320116888Open ↗
Showing 3 of 5 on file for this type
▸BISWORK PERMIT APPLICATION3
05/22/2018321755310Open ↗
04/21/2010320095829Open ↗
04/05/2010320116888Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
05/13/2010320116888Open ↗
▸Seals & Professional Certifications18
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION5
05/15/2018321755310Open ↗
07/23/2010320095829Open ↗
04/21/2010320095829Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
08/31/2026B01162039-I1Open ↗
08/31/2026B01162039-I1Open ↗
08/31/2026B01162039-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/31/2026B01162039-I1Open ↗
08/31/2026B01162039-I1Open ↗
08/31/2026B01162039-S1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
09/03/2026B00049406-I1Open ↗
08/23/2026B01162039-I1Open ↗
08/23/2026B01162039-S1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
05/15/2018321755310Open ↗
▸BISProfessional and Owner Certification (POC3)1
05/15/2018321755310Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING1
11/25/2009320095829Open ↗
▸BISSELF-CERT PLUMBING NOTICE1
05/20/2010320095829Open ↗
▸Safety & Tenant Protection3
▸BISSTREET TREE CHECKLIST2
12/31/2009320116888Open ↗
11/25/2009320095829Open ↗
▸BISST-1 Street Tree Checklist1
03/05/2010320116888Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
09/03/2026B00049406-I1Open ↗
08/23/2026B01162039-I1Open ↗
08/23/2026B01162039-S1Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
12/31/2009320116888Open ↗
11/25/2009320095829Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
05/15/2018321755310Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
06/21/2018321755310Open ↗
05/15/2018321755310Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
06/21/2018321755310Open ↗
▸Inspections & Test Reports1
▸BISINSPECTION REPORT - SUPPORTING DOCUMENTATION1
06/21/2018321755310Open ↗
▸Approvals, Objections & Sign-offs11
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST6
06/21/2018321755310Open ↗
11/18/2010320116888Open ↗
07/23/2010320095829Open ↗
Showing 3 of 6 on file for this type
▸BISADMINISTRATIVE OBJECTIONS3
05/15/2018321755310Open ↗
12/31/2009320116888Open ↗
11/25/2009320095829Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE2
12/31/2009320116888Open ↗
03/01/2010320116888Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT4
06/21/2018321755310Open ↗
05/15/2018321755310Open ↗
07/08/2010320095829Open ↗
Showing 3 of 4 on file for this type
▸Filing & Intake Forms4
▸BISEFILING COVER SHEET3
05/15/2018321755310Open ↗
12/31/2009320116888Open ↗
11/25/2009320095829Open ↗
▸BISBOROUGH INTAKE FORM1
06/21/2018321755310Open ↗
▸Other Documents1
▸BISPLOT DIAGRAM1
12/31/2009320116888Open ↗