← Back
Miscellaneous two family
6322 5 AVENUE
BROOKLYN · BIN 3144092
💬 Discuss this project
1931Year Built
2Stories
B9Building Class
R6AZoning
2,200 sfGross Floor Area
2Units
3 Open Violations ▸FDNY Report ↗
Miscellaneous two family · Owner of record: SUNSET 63 LLC · 1,500 sf lot · 1.47 FAR built · Flood zone X
Locations of Work
Architecture
Permit Issued — active, not yet Signed-off
Floor 1Under Construction5p · 1 filing · 11 docs
CellarUnder Construction4p · 1 filing · 11 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SUNSET 63 LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/11/2024$1.2M—Private party → SUNSET 63 LLC$550/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
STUDIO WL ARCHITECTURE PLLC105/02/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LEDOS CONSTRUCTION INCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
FACTORY ENGINEERING WORKS8855105/02/2025
Building Lifecycle
All (16)Filed (1)Permit Issued (1)Violation (3)Objection (6)Special Inspection (5)
06/18/2026
Violation issued (ECB, open)
Construction
06/15/2026
Violation issued (ECB, open)
Construction
04/07/2026
Permit issued — General Construction
B01218119-I1-GC
12/19/2025
Objection resolved — Addressed
05/20/2025
Objection resolved — Addressed
05/20/2025
Objection resolved — Addressed
05/09/2025
Objection raised — Fire_Protection
05/09/2025
Objection raised — Cost
05/09/2025
Objection raised — Inspections
05/02/2025
Filed — Alteration CO
PROPOSED CHANGE OF BUILDING'S USE FROM THE EXISTING TWO DWELING UNITS AND ONE COMMERCIAL UNIT TO THE PROPOSED ONE DWELLING UNIT AND ONE COMMERCIAL UNIT. WORK INVOLVES NEW INTERIOR PARTITIONS. A NEW CERTIFICATE OF OCCUPANCY IS REQ'D.
B01218119-I1
05/01/2025
Special inspection requirement — Tenant Protection Plan Compliance
Kui He
04/30/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kui He
04/30/2025
Special inspection requirement — Energy Code Compliance Inspections
Kui He
04/30/2025
Special inspection requirement — Lighting controls
Kui He
04/30/2025
Special inspection requirement — Interior lighting power
Kui He
04/18/2025
Violation issued (ECB, open)
Unknown
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedLEDOS CONSTRUCTION INC04/07/2026
1 project · most recent 06/24/2025
General Wiring
FiledStatusContractorScope
06/24/2025Permit IssuedRIVIERA ELECTRIC CORPGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
05/01/2025Tenant Protection Plan ComplianceKui Hespecial
04/30/2025Fire-Resistant Penetrations and JointsKui Hespecial
04/30/2025Energy Code Compliance InspectionsKui Heprogress
04/30/2025Lighting controlsKui Heenergy_progress
04/30/2025Interior lighting powerKui Heenergy_progress
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/21/2026B01218119-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B01218119-I1Open ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
08/27/2026B01218119-I1Open ↗
08/27/2026B01218119-I1Open ↗
08/27/2026B01218119-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/27/2026B01218119-I1Open ↗
08/27/2026B01218119-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026B01218119-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026B01218119-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026B01218119-I1Open ↗
▸Other Documents1
▸DOB NOWProperty Ownership Certification1
08/13/2026B01218119-I1Open ↗